• Title/Summary/Keyword: Oxygen Utilization Coefficient

Search Result 7, Processing Time 0.019 seconds

A Study on the Software development for the correlation of the water pollution of pollution material analysis (공해물질분석에 관한 수질오탁의 상관성 계산 위한 SOFTWARE 개발에 관한 연구)

  • 택훈
    • Journal of the Speleological Society of Korea
    • /
    • v.15 no.16
    • /
    • pp.38-60
    • /
    • 1987
  • There are BOD(Biochemical Oxygen Demand) and COD(Chemical Oxygen Demand) in the date of the water pollution in the pollution analysis, BOD and COD analysis the result of the analysis. The computer developed the program in the analysis. Went by BOD, the relation conversion equation type of COD, the control chart, the standard deviation, and the coefficient of correlation etc.. for the purpose of the development of the program. There is a purpose by which it is what coefficient of correlation in the development of this program or not if the value (X and Y) of unknow is understood. In the future, if this program is applied the utilization to not only the data is analyzed about the water pollution but also a lot of fields is proposed.

  • PDF

Estimation of Kinetic Parameters for Biomass Growth Using Micro-nano Bubbles Reactor (마이크로-나노버블 반응조를 이용한 미생물성장 동력학 계수의 추정에 관한 연구)

  • Han, Young-Rip;Jung, Byung-Gil;Jung, Yoo-Jin;Cho, Do-Hyun;Sung, Nak-Chang
    • Journal of Environmental Science International
    • /
    • v.19 no.5
    • /
    • pp.647-653
    • /
    • 2010
  • The objectives of this research are to evaluate and compare the oxygen transfer coefficients($K_{La}$) in both a general bubbles reactor and a micro-nano bubbles reactor for effective operation in sewage treatment plants, and to understand the effect on microbial kinetic parameters of biomass growth for optimal biological treatment in sewage treatment plants when the micro-nano bubbles reactor is applied. Oxygen transfer coefficients($K_{La}$) of tap water and effluent of primary clarifier were determined. The oxygen transfer coefficients of the tap water for the general bubbles reactor and micro-nano bubbles reactor were found to be 0.28 $hr^{-1}$ and 2.50 $hr^{-1}$, respectively. The oxygen transfer coefficients of the effluent of the primary clarifier for the general bubbles reactor and micro-nano bubbles reactor were found be to 0.15 $hr^{-1}$ and 0.91 $hr^{-1}$, respectively. In order to figure out kinetic parameters of biomass growth for the general bubbles reactor and micro-nano bubbles reactor, oxygen uptake rates(OURs) in the saturated effluent of the primary clarifier were measured with the general bubbles reactor and micro-nano bubbles reactor. The OURs of in the saturated effluent of the primary clarifier with the general bubbles reactor and micro-nano bubbles reactor were 0.0294 mg $O_2/L{\cdot}hr$ and 0.0465 mg $O_2/L{\cdot}hr$, respectively. The higher micro-nano bubbles reactor's oxygen transfer coefficient increases the OURs. In addition, the maximum readily biodegradable substrate utilization rates($K_{ms}$) for the general bubbles reactor and micro-nano bubbles reactor were 3.41 mg COD utilized/mg active VSS day and 7.07 mg COD utilized/mg active VSS day, respectively. The maximum specific biomass growth rates for heterotrophic biomass(${\mu}_{max}$) were calculated by both values of yield for heterotrophic biomass($Y_H$) and the maximum readily biodegradable substrate utilization rates($K_{ms}$). The values of ${\mu}_{max}$ for the general bubbles reactor and micro-nano bubbles reactor were 1.62 $day^{-1}$ and 3.36 $day^{-1}$, respectively. The reported results show that the micro-nano bubbles reactor increased air-liquid contact area. This method could remove dissolved organic matters and nutrients efficiently and effectively.

Bio-kinetic and Design Analysis of a Sequencing Batch Reactor by Aerobic Granular Sludge (호기성 입상화 슬러지를 이용한 SBR 운전의 동력학적 해석 및 설계분석)

  • Choi, Seong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.275-280
    • /
    • 2011
  • In the present work, the aerobic particle's characteristics were enhanced. A polymer was used to make aerobic granular sludge in short period of time. And operation parameters were calculated for organic matter removal in domestic wastewater using a sequencing batch reactor (SBR). The experiment for sewage (Influent concentration of 63~72 mg COD/L) by using mature aerobic granular sludge showed the organic matter removal rate k and oxygen utilization coefficient a', b' were $10.161d^{-1}$ and 0.87 mg $O_2/mg$ $COD_r$, 0.11 mg $O_2/mg$ MLVSS d respectively. Therefore, it was more effective than K value $5{\sim}8d^{-1}$ of conventional activated sludge process. The sludge synthetic value and sludge auto-oxydation value were 0.45 mg VSS/mg $COD_r$ and 0.05 mg VSS/mg MLVSS d respectively. Consequently, mortality rates of microorganisms was lower than conventional activated sludge process.

Adaptive Control of Denitrification by the Extended Kalman Filter in a Sequencing Batch Reactor (확장형칼만필터에 의한 연속회분식반응조의 탈질 적응제어)

  • Kim, Dong Han
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.829-836
    • /
    • 2006
  • The reaction rate of denitrification is primarily affected by the utilization of organics that are usually limited in the anoxic period in a sequencing batch reactor. It is necessary to add an extemal carbon source for sufficient denitrification. An adaptive model of state-space based on the extended Kalman filter is applied to manipulate the dosage rate of extemal carbon automatically. Control strategies for denitrification have been studied to improve control performance through simulations. The normal control strategy of the constant set-point results in the overdosage of external carbon and deterioration of water quality. To prevent the overdosage of external carbon, improved control strategies such as the constrained control action, variable set-point, and variable set-point after dissolved oxygen depletion are required. More stable control is obtained through the application of the variable set-point after dissolved oxygen depletion. The converging value of the estimated denitrification coefficient reflects conditions in the reactor.

Effects of Dissolved Oxygen and Agitation on Production of Serratiopeptidase by Serratia Marcescens NRRL B-23112 in Stirred Tank Bioreactor and its Kinetic Modeling

  • Pansuriya, Ruchir C.;Singhal, Rekha S.
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.4
    • /
    • pp.430-437
    • /
    • 2011
  • The effects of the agitation and aeration rates on the production of serratiopeptidase (SRP) in a 5-L fermentor (working volume 2-l) were systematically investigated using Serratia marcescens NRRL B-23112. The dissolved oxygen concentration, pH, biomass, SRP yield, and maltose utilization were all continuously measured during the course of the fermentation runs. The efficiencies of the aeration and agitation were evaluated based on the volumetric mass transfer coefficient ($K_La$). The maximum SRP production of 11,580 EU/ml with a specific SRP productivity of 78.8 EU/g/h was obtained with an agitation of 400 rpm and aeration of 0.075 vvm, which was 58% higher than the shake-flask level. The $K_La$ for the fermentation system supporting the maximum production (400 rpm, 0.075 vvm) was 11.3 $h^{-1}$. Under these fermentor optimized conditions, kinetic modeling was performed to understand the detailed course of the fermentation process. The resulting logistic and Luedeking-Piret models provided an effective description of the SRP fermentation, where the correlation coefficients for cell growth, SRP formation, and substrate consumption were 0.99, 0.94, and 0.84, respectively, revealing a good agreement between the model-predicted and experimental results. The kinetic analysis of the batch fermentation process for the production of SRP demonstrated the SRP production to be mixed growth associated.

Characteristics and Effective Usage of Organic Indexes in Water Environments -Lakes in Nakdong River Basin- (물환경에서의 유기물질 지표 특성 및 효율적 이용방안 -낙동강수계 호소수를 대상으로-)

  • Kang, Meea
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.153-160
    • /
    • 2014
  • TOC environmental standard was established to understand the pollution level accurately and to improve the water quality. It was found that the relationship between COD and TOC showed a significant coefficient($R^2$=0.639) in four lakes for drinking water located in Nakdong River basin. The relationship between COD and TOC($R^2$=0.774) was higher with respect to the elevated concentration level when the data was added. Resulting in the oxidation(C) was $62{\pm}8%$ regardless of COD concentrations. It was difficult to find a significant difference by lakes. The result showed the similar organic property in study lakes. It was necessary to evaluate the level of organic matters in consideration of characteristics and utilization of lakes to use COD data wisely until TOC data be accumulated sufficiently.

Effect on nitrogen removal in the intermittent aeration system with the anaerobic archaea added (혐기성 아키아 주입이 간헐폭기 시스템에서 질소제거에 미치는 영향)

  • Lee, Sang-Hyung;Park, Noh-Back;Park, Sang-Min;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1186-1192
    • /
    • 2005
  • The relationship between bacteria and anaerobic archaea, sludge yield coefficient and nitrogen removal rate were investigated in intermittent aeration systems(I/A) with added archaea, I/A and conventional activated sludge system. As the archaea solution was added to the I/A reactor, organic removal rate as well as nitrogen removal rate increased. Also, sludge production rate in I/A system added the archaea was maintained lower than other systems because sludge yield coefficient was decreased due to the role of anaerobic archaea such as anaerobic degradation of organics. The experimental data supported the possibility of symbiotic activated sludge system with anaerobic archaea under intermittent aeration, leading to the enhanced nitrogen removal. Crucial results to be presented are: 1) specific oxygen utilization rate(SOUR) of the I/A-arch system was $2.9\;mg-O_2/(g-VSS{\cdot}min)$. SOUR and nitrification rate of the sludge from the I/A-arch system was higher than those from the I/A and A/S reactors. 2) Removal efficiencies of $TCOD_{Cr}$ in the I/A-arch, I/A and A/S reactors were 93, 90 and 87%, respectively. 3) Nitrification occurred successfully in each reactor, while denitrification rate was much higher in the I/A-arch reactor. Efficiencies of TN removal in the I/A-arch, I/A and A/S reactors were 75, 63 and 33%, respectively.