• Title/Summary/Keyword: Oxygen Flow Rate

Search Result 689, Processing Time 0.026 seconds

Effect of Cr on Flow Accelerated Corrosion of Carbon Steel (탄소강의 유동가속부식에 미치는 크롬의 영향)

  • Lee, Eun Hee;Kim, Kyung Mo;Kim, Hong Pyo;Kim, Dong Jin
    • Corrosion Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.25-32
    • /
    • 2015
  • The alloy content of structural materials of nuclear power plants has been recognized an important factor in predicting flow accelerated corrosion (FAC). In particular, many literature data reported that chromium content is one of the most important alloying element and even a small amount of chromium is effective to suppress FAC. This report reviewed and compared chromium models of Ducreux, Bouchacourt, and Kastner which were used in predicting FAC rates. The plant data indicate that Ducreux model may be conservative for the specimen containing 0.15 wt% chromium. The related articles were reviewed as follows. Combined effects of chromium content, pH, temperature, dissolved oxygen (DO), flow velocity, test time, and kinds of amine on the FAC rate were described. 0.1 wt% chromium in steel did not affect the FAC rate with changes in pH. The FAC rates pronounced with higher flow rate and increased with increasing test duration(600 d) for 0.013 wt% chromium. The FAC rates in mixed amine chemistry were higher than in ammonia chemistry, which may be lessened by the addition of chromium to the steel.

Optimal DO Setpoint Decision and Electric Cost Saving in Aerobic Reactor Using Respirometer and Air Blower Control (호흡률 및 송풍기 제어 기반 포기조 최적 DO 농도 설정과 전력 비용 절감 연구)

  • Lee, Kwang Su;Kim, Minhan;Kim, Jongrack;Yoo, Changkyoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.581-586
    • /
    • 2014
  • Main objects for wastewater treatment operation are to maintain effluent water quality and minimize operation cost. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. The oxygen uptake rate (OUR) is real-time measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO set-point needed for the micro-organism is suggested based on real-time measurement of oxygen uptake of micro-organism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal set-point decision system by providing the necessary oxygen supply requirement to the micro-organisms coping with the variations of influent loading.

The Role of Jugular Venous Oxyhemoglobin Saturation Monitoring During Cardic Surgery (개심술 중 경정맥 산소포화도의 역할)

  • Kim, Sae-Yeon;Jee, Dae-Lim
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 1994
  • Postoperative brain damage is one of most serious complications of cardiopulmonary bypass (CPB). To prevent brain damage during CPB, adequate cerebral perfusion for cerebral oxygen demand should be maintained. This study monitored jugular venous oxyhemoglobin saturation ($SjO_2$), which reflects the overall balance of cerebral oxygen supply and demand, intermittently in 10 patients undergoing cardiac surgery. At the initiation of CPB, in spite of a significant decrease in mean arterial pressure, $SjO_2$ did not change, and it was stable during the hypothermic period of CPB. But a significan reduction in $SjO_2$ was observed during the rewarming period, and $SjO_2$ had an inverse linear correlation with esophageal temperature. Furthermore, the percent decrease of $SjO_2$ was related to rewarming speed. Therefore, therapeutic approaches for $SjO_2$ desaturation include slower rewarming, increasing cerebral blood flow, decreasing the cerebral metabolic rate for oxygen, increasing oxygen content, and increasing perfusion flow rate.

  • PDF

Improvement of Barrier Property of LDPE Food Packaging Film by Plasma Polymerization (플라스마 중합을 이용한 LDPE 식품포장 필름의 차단성 향상)

  • Kim, Kyoung-Seok;Cho, Dong-Lyun
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.38-42
    • /
    • 2008
  • Ultrathin films were coated on low density Polyethylene (LDPE) food packaging films by plasma polymerization of methane, acetylene, hexamethyldisiloxane (HMDSO), and HMDSO+oxygen to improve the barrier property of the LDPE films. The film coated in HMDSO +oxygen (flow rate: 0.6+ 9.0 SCCM) plasma at 40 W for 10 min showed the highest improvement in the barrier property against oxygen, reducing the permeability of oxygen as much as 18.6 times. The film coated in acetylene (flow rate 0.75 SCCM) plasma at 10 W for 10 min showed the highest improvement in the barrier property against carbon dioxide and moisture, reducing the permeability of carbon dioxide and moisture as much as 12.0 and 3.0 times, respectively. In addition, cherry tomato, cucumber, and mushroom (Flammulina velutipes) wrapped with the coated films were kept fresh $1.5{\sim}3.0$ times longer than those wrapped with an LDPE film.

A/F Control of an MPI Engine on Transient Conditions with an Intergration type Ultrasonic Flow Meter (적분형 초음파 유량계를 이용한 MPI 엔진의 비정상상태 공연비 제어)

  • 김중일;장준석;고상근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.36-47
    • /
    • 1999
  • Three-way catalyst converter, cleaning up the exhaust gas contamination of SI engine, has the best efficiency when A/F ratio is near the stoichiometry . The feedback control using oxygen sensors in the exhaust manifold has limits caused by the system delays. So the accurate measurement of air flow rate to an engine is essential to control the fuel injection rate especially on transient condition like the rapid throttle opening and closing. To measure the rapid change of flow rates. the air flow meter for the engine requires quick response, flow reversal detection, and linearity . Tjhe proposed integration type air flow meter (IFM), composed of an ultrasonic flow meter with an integration circuit, has significantly improved the measurement accuracy of air mass inducted through the throttle body. The proposed control method estimated the air mass at the cylinder port using the measured air mass at the throttle . For the fuel dynamic model, the two constant fuel model is introduced . The control parameters from air and fuel dynamics are tuned to minimize the excursion of the air fuel ratio. As a result A/F ratio excursion can be reduced within 5% when throttle rapidly opens and closes at the various engine conditions.

  • PDF

The Evaluation of Oxygen Generator Performance For Car (차량용 산소발생기의 성능 측정)

  • Song, Kun-Ho;Yu, Jin-Ho;Kim, Jeong-Eun;Chang, Wha-Ik;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.151-156
    • /
    • 2005
  • Auto exhausts and air pollution can become trapped in the cabin of vehicle, reducing the amount of oxygen available for breathing. Driver may feel sleepy, headaches, nausea, confusion, dizziness and lower levels of oxygen can damage the driver's general health. Consequently, oxygen generator purified oxygen into the car to help driver get the oxygen driver's body needs. In this study, in order to evaluate the oxygen generator performance, the samples that the various conditions(humidity(50%, 100%), flow and oxygen concentration) were examined. There were three types of oxygen generator; sample 1($2.5{\ell}/min$, $36%O_2$), sample 2($4.5{\ell}/min$, $41%O_2$) and sample 3($5{\ell}/min$, $39%O_2$). As the humidity increased from 50% to 100%, the oxygen concentration of the sample 1(36%), 2(41%) and 3(39%) was reduced $31%O_2$, $38%O_2$ and $38%O_2$, respectively. Also, the each sample measured that effect of human in car on oxygen concentration, if the oxygen concentration is one person in car, each sample of oxygen concentration was $20.8%O_2$, $23.7%O_2$ and $21.2%O_2$. From the above results, it was shown that oxygen generator for car, if the oxygen concentration is increased, effect of humidity is reduced, and that in the sample of supplying a high-rate of oxygen, the oxygen concentration is increased. It was suggested that effect of humidity on oxygen generator for car can be reduced according to the supply of oxygen.

  • PDF

High Concentration Ozone Generation Characteristics by Variation of Additional Gases and Flow Rates of Inlet Gas (입력가스의 유량변화와 첨가가스에 따른 고농도 오존발생특성)

  • 박승록;이대희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2002
  • There are many effective parameters to high concentration ozone generation. These parameters became very important elements should be considered before designing ozone generator. After designing, there are many peripheral parameters to greatly affect to high concentration ozone generation also. In this study, of many effective peripheral parameters on high concentration ozone generation, the effects of flow rate of inlet oxygen gas and some kinds of additional gases on ozone concentration were investigated As a result, when inlet oxygen gas was introduced at the range of 0.75[LPM]~2.00[LPM] the highest ozone concentration of 71145[ppm] was obtained at 1.25[LPM]. When the additional nitrogen gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest ozone concentration of 73135[ppm] was obtained at 0.8[vol%] of nitrogen gas. This showed 3[%] increasing compared to the case of pure oxygen gas inlet. When the additional argon gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest concentration of 67288[ppm]was obtained at 0.8[vol%]of argon gas. This is decreased value compared to that of introducing the pure oxygen.

Decomposition of Trchloroethylene/Air Mixture by Electron Beam Irradiation in a Flow Reactor (전자빔을 이용한 흐름반응기에서의 Trichloroethylene/Air 분해)

  • ;;;Tatiana Stuchinskaya
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.97-104
    • /
    • 2001
  • Decomposition of trichloroethlyene(TCE) in electron beam irradiation was examined on order to obtain information on the treatment of VOC in air. Air containing vaporized TCE has been studied in a flow reactor with different reaction environments, at various initial TCE concentration and in the presence and absence of water vapor. Maximum decomposition was observed in oxygen reaction environment and the degree of decomposition was about 99% at 20kGy for 2,000ppm initial TCE. The concentration of TCE exponentially decreased with dose in air and pure oxygen. The effect of water vapor on TCE decomposition efficiency was examined. The decomposition rate of TCE in the presence of water vapor (5,600 ppm) was approximately 10% higher than that in the absence of water vapor. Dichloroacetic acid, dichloroacethyl chloride and dichloroethyl ester acid were identified as primary products of this reaction adn were decomposed and oxidized to yield CO and $CO_2$. Perchloroethylene, hexachloroethane, chloroform and carbon tetrachloride were also observed as highly chlorinat-ed by products.

  • PDF

Insulation Properties and Microstructure of SiO$_2$ Film Prepared by rf Magnetron Sputtering (고주파 마그네트론 스퍼터링으로 제조한 SiO$_2$ 절연박막의 구조분석 및 절연저항에 관한 연구)

  • 박태순;이성래
    • Journal of Surface Science and Engineering
    • /
    • v.35 no.2
    • /
    • pp.113-121
    • /
    • 2002
  • We have investigated insulating properties of $SiO_2$ interlayer for the thin film strain gauge, which were prepared by RF magnetron sputtering method in various deposition conditions, such as Ar pressure, gas flow rates and sputtering gases. SEM, AFM and FT-IR techniques were used to analyze its structures and composition. As the Ar pressure and the flow rate increased, the insulating interlayer showed low insulating resistance due to its porous structure and defects. Oxygen deficiency in $SiO_2$ was decreased as fabricated by hydrogen reactive sputtering. We could enhance the surface mobility of sputtered adatoms by using Ar/$H_2$ sputtering gas and obtain a good surface roughness and insulating property. The optimum insulating resistance of 9.22 G$\Omega$ was obtained in Ar/30% $H_2$ mixed gas, flow rate 10sccm, and 1mTorr.

Clinical Experience of Long-term Home Oxygen Therapy (재택산소요법을 받고 있는 환자들에 대한 임상 관찰)

  • Lee, Young-Suk;Cha, Seung-Ick;Han, Chun-Duk;Kim, Chang-Ho;Kim, Yeun-Jae;Park, Jae-Yong;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.283-291
    • /
    • 1993
  • Background: Long-term low flow oxygen therapy not only increases survival, but also improves the quality of life in patients with chronic obstructive pulmonary disease (COPD) with chronic hypoxemia. For the assessment and improvement of the status of home oxygen therapy, we analyzed clinical experience of 26 patients who have been administered low flow oxygen at home. Method: Twenty-six patients (18 men and 8 women) who have been received long-term oxygen therapy (LTOT) at home were examined. We reviewed physical characteristics, clinical history, pulmonary function test, ECG, arterial blood gas analysis, hemoglobin and hematocrit, types of oxygen devices, inhalation time per day, concentration of administered $O_2$, duration of $O_2$ therapy, and problems in the home oxygen therapy. Results: The underlying diseases of patients were COPD 14 cases, far advanced old pulmonary tuberculosis 9 cases, bronchiectasis 2 cases, and idiopathic pulmonary fibrosis 1 case. The reasons for LTOT at home were noted for cor pulmonale 21 cases, for dyspnea on exertion and severe ventilatory impairment 4 cases, and for oxygen desaturation during sleep 1 case. The mean values of aterial blood gas analysis before home oxygen therapy were $PaO_2$ 57.7 mmHg, $PaCO_2$ 48.2 mmHg, and $SaO_2$ 87.7%. And the mean values of each parameters in the pulmonary function test were VC 2.05 L, $FEV_1$ 0.92 L, and $FEV_1$/FVC% 51.9%. Nineteen patients have used oxygen tanks as oxygen devices, 1 patient oxygen concentrator, 2 patients oxygen tank and liquid oxygen, and other 4 patients oxygen tank together with portable oxygen. The duration of oxygen therapy was below 1 year in 3 cases, 1~2 years in 15 cases, 3~5 years in 6 cases, 9 years in 1 case, and 10 years in 1 case. All patients have inhalated oxygen with flow rate less than 2.5 L/min. And only 10 patients have inhalated oxygen more than 15 hours per day, but most of them short time per day. Conclusion: For the effective oxygen administration, it is necessary that education for long-term low flow oxygen therapy to patients, their family and neighbor should be done, and also the institutional backup for getting convenient oxygen devices is required.

  • PDF