• 제목/요약/키워드: Overvoltage Protection Function

검색결과 7건 처리시간 0.018초

발전기 과여자 및 과전압 계전기 보호협조에 관한 연구 (A Study on the Protective Coordination of Generator Overexcitation and Overvoltage Relay)

  • 박지경;김광현;김철환;유영식;양정재
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1187-1194
    • /
    • 2017
  • After North American wide area black out on August 14, 2003, various studies have been conducted to find out the reason of the disaster. One of main reasons was misoperation of generator protection system. Since then, protective coordination between generator protection system and excitation system controls has been hot issue among electrical engineers. Among various generator protection relays, in this paper, we focused on generator overvoltage and overexcitation relay, which protect the over-flux condition of the generator. Thus, at first, we modeled the generator overvoltage, overexcitation relay and detailed power system including excitation system, governor and etc., based on actual field data. And then, we reviewed the protective coordination of generator overvoltage and overexcitation relay using electromagnetic transient program. In addition, we discussed the protective coordination method for redundant protection relays in both automatic voltage regulator and generator side.

방전등 안정기의 보호회로 기술 현황 (A Stuty of Protection Circuit for Discharge Lamp Ballast)

  • 한수빈;박석인;송유진;정학근;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2008
  • In a design of ballast for discharge lamp, various kind of protection circuit are essential for safe operation. In this paper, overvoltage and current detection, no-load detection, lamp-fault detection, end of lamp detection for protection are introduced. Individual circuit operation and their function are described with the base that all circuit form is similar with overvoltage protection circuit.

  • PDF

펄스전력용 광점호 싸이리스터의 특성 연구 (A Study on Characteristics of Light Triggered Thyristor for Pulsed Power Application)

  • 이병하;김진성;김영배;차한주
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.762-767
    • /
    • 2010
  • This paper describes characteristic of a light triggered thyristor investigated by experiment to adopt it into a main switch of a pulsed power unit. Triggering principle of the light triggered thyristor are referred with its structure and equivalent circuit. Operational principle and simulation result of a capacitive pulsed power circuit are explained. A variety of triggering conditions of triggering circuit and characteristics on turn-on, turn-off, voltage dividing in series operation, overvoltage protection function of the light triggered thyristor are investigated by experiments. Experimental result of 40 kJ pulsed power unit using the light triggered thyristor is presented.

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

HVDC시스템의 직류측 보호 모델 개발 (The Assessment and Development of Protection Models in HVDC DC side)

  • 이성두;김찬기
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1754-1760
    • /
    • 2010
  • The HVDC system consists of ac side and dc side through thyristor valve. ac side protection is similar to conventional ac system protection schemes but dc side protection is different from ac side of HVDC system. AC system don't have controller but HVDC system has controller that controls and protects system from faults and disturbance. This paper show protectional function of HVDC dc side such as asymmetry protection, ac/dc differential protection, dc overvoltage, dc overcurrent protection. Protection models is developed using RTDS software and assessment of protection models is also performed by RTDS system.

Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계 (Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function)

  • 김홍주;하판봉;김영희
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.132-139
    • /
    • 2020
  • 공기청정기에 사용되는 이오나이저 모듈은 권선형 transformer를 사용하여 방전전극인 HV+/HV-에 3.5KV/-4KV의 고전압을 공급하여 carbon fiber brush의 전계 방사에 의해 양이온과 음이온을 발생시킨다. 기존의 MCU를 이용한 이오나이저 모듈 회로는 PCB 사이즈가 크고 가격이 비싼 단점이 있고, 기존의 ring oscillator를 이용한 게이트 구동 칩은 oscillation 주기가 PVT(Process-Voltage-Temperature) 변동에 민감하고 HV+와 GND, HV-와 GND의 단락에 의한 fault detection 기능이 없으므로 화재나 감전의 위험이 있다. 그래서 본 논문에서는 7bit binary UP counter를 이용하여 PVT 변동이 있더라도 oscillation 주기를 조절하여 HV+ 전압이 목표 전압에 도달하게 한다. 그리고 HV+와 GND 사이의 단락을 검출하기 위한 HV+ short fault detection 회로, HV-와 GND 사이의 단락을 검출하기 위한 HV- short fault detection 회로와 HV+가 과전압 이상으로 올라가는 것을 검출하기 위한 OVP(Over-Voltage Protection) 회로를 새롭게 제안하였다.

가전기기용 직류전원 모듈 설계 및 신뢰성 특성 해석 (Design and Reliability Evaluation of 5-V output AC-DC Power Supply Module for Electronic Home Appliances)

  • 모영세;송한정
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.504-510
    • /
    • 2017
  • 본 논문은 소형 가전기기를 위한 AC DC 파워모듈 설계를 제시하고 효율과 신뢰성 및 안정성 특성을 나타낸다. 제안하는 파워모듈은 PCB 테스트보드에서 PWM 제어 IC 칩, 파워모스 소자, 트랜스포머, 각종 수동소자 (저항, 커패시터, 인덕터)를 사용하여 제작하였다. 본 논문에서 제시한 AC DC 파워모듈 회로 시뮬레이션 결과를 토대로 측정한 실험에서 입력전압은 상용전원 전압 220 V (RMS), 주파수 60 HZ의 교류전압(VAC : Voltage alternating current)을 사용 하였으며, 출력전압, OCP (over current protection), EMI(electromagnetic interference), PWM 신호 펄스, 효율 측정, 패키징 여부에 따른 발열측정 등을 실시하였다. 또한 파워모듈의 온도에 따른 특성변화와 트랜스포머 기준으로 1차측의 회로와 2차측 회로의 절연상태 확인을 하기 위한 내전압 테스트 등의 신뢰성테스트를 실시하였다. 효율 및 신뢰성 측정결과, AC DC 파워 모듈이 5 V의 출력전압, 200 mV의 리플, 약 73 %의 효율, 온도 약 $80^{\circ}C$ 까지 안정적으로 동작함을 확인하였으며, 4.2 kV의 크기로 60초 동안 견디는 내압 성능을 보였다.