• Title/Summary/Keyword: Overseas Plant

Search Result 200, Processing Time 0.026 seconds

A Economic Evaluation for APR+ Standard Design (APR+ 표준설계에 대한 경제성 분석)

  • Ha, Gag-Hyeon;Lee, Jae-Ho
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.43-47
    • /
    • 2016
  • KHNP CRI has developed APR+ nuclear power plant since 2007, which is GEN III+ model with 1500 MWe capacity. To develop safer nuclear power plant than APR1400, we investigated advanced design features of ALWR being constructed in Korea and being developed/constructed in foreign countries. We applied the advanced design features and lessons learned from Fukushima accident to develop APR+ standard design suitable for both domestic construction and overseas construction business. One economic assessments have performed during safety design improvement phase(2013.1 ~ 2015.12) of APR+. The result of the economic analysis for APR+ safety inhancement design showed that APR+ N-th plant is about 39.2% more economical than coal-fired 1,000MW power plant. Also APR+ plant is more cost advantage over foreign advanced nation ALWRs.

A Study on Plant Diet Resource of Nutria(Myocastor coypus) Habitat in Nakdong-river (낙동강에 서식하는 뉴트리아(Myocastor coypus)의 식물 먹이 자원에 관한 연구)

  • Lee, Do-Hun;Lee, Chang-Woo;Kil, Jihyon
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.5
    • /
    • pp.491-511
    • /
    • 2013
  • In this study, three survey areas in Changnyeong, Miryang and Jinju of the confirmed the habitation of nutria and carried out the performance on the plant diet resource. From the habitat trace survey in the nutria habitat, a total of 336 trace points was shown. There were 181 trace points (54%) confirmed from St. 1 as the highest showing, followed by 52 trace points (15.4%) from St. 2, and 103 trace points (30.6)% from St. 3. The vascular plants distributed in the habitat area were a total of 182 taxonomic group with 57 families, 99 genus, 16 hybrids, and 1 race. The vascular plant living types in the habitat area are 1-year plant (Th, Th(w)) for 63class groups (34.6%), hemicryptophyte (H) for 42class groups(23.1%). plants, trees, crop plants were included. As a result of analyzing the overseas research cases on the diet plants of nutria, there are 195 taxonomic groups in a total of 39 families, 126 genus, 183 breeds, and 12 hybrids. In the study areas, feeding the plants was confirmed by the 7 taxonomic groups, aquatic plant, terrestrial From the total of 182 taxonomic groups discovered in the habitat area, 20 class groups, in 3 habitation region, 10 class groups of commonly appearing 49 class groups were shown to be the breed confirmed for diet in existing case studies, and assuming from it basis, the nutria habitating in the survey area is considered to have the supply of diverse diet resource to have flawless habitation. This is implication of having potential breeding possibility.

Research of Solid Propellant Electrostatic Sensitivity in Confinement (밀폐공간에서의 추진제 정전기 민감도에 대한 연구)

  • Choi, Jiyong;Lee, Seonjae;Kim, Jihong;Kim, Jinyong;Park, Euiyong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.4
    • /
    • pp.73-78
    • /
    • 2020
  • The main reasons that ignite the propellant in the process of producing solid rocket motor are worker mistakes, wrong working process, mechanical defects, impact, friction, electrostatic and short circuits. In the past decades, many accidents have occurred in the process of producing solid rocket motor, accidents investigation have confirmed that the sensitivity of electrostatic is very high under specific condition. In this paper, we analyzed overseas accident cases and measured the sensitivity of electrostatic in the situation of confinement and pressure load by considering the manufacturing process. As a result of the test, the sensitivity of propellant was increased in the situation of confinement and pressure load and the propellant reacted more sensitively to electrostatic in the situation of confinement than pressure load.

Development of Web-based Power Plant Simulator System (원격 훈련용 발전 시뮬레이터 개발)

  • Byun, Seung-Hyun;Kang, Hae-su;Woo, Joo-Hee;Lee, Jee-Hoon;Kim, Duck-Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.277-283
    • /
    • 2021
  • Power plant simulators have been used for operator training, control verification and engineering verification. In general, simulators can be used in the place where they are installed by only single user group at a time. Considering high cost of simulator development, a lot of available scenarios, the diversity of user level and accessibility based on users' work location, development of simulator system that can be used by multiple user groups regardless of location is required in order to enhance utilization of simulators. In this paper, the simulator system that can be used by multiple user group simultaneously without location limitation is proposed. The simulator system is composed of simulator servers, database servers, HMI servers, a web server, web clients. Simulator server consists of control model, process model that are developed for Circulating Fluidized Bed power plant located overseas. A web server manages user accounts, operation procedures, multiple server access between web client group and simulator server group. In other words, a web server makes a user group select a simulator server at a time. The developed simulator system is integrated after implementing process model, control model, HMI, and web server. Web client systems are installed on local site where power plant is located, while simulator servers, HMI servers, database servers, and a web server are located in KEPCO RI. The developed simulator system is verified by steady-state test, malfunction test and so on via remote access.

A Basic Study on NCS Development and Professional Training Activation for DP Operators (DP운항사 NCS개발 및 전문인력양성 활성화 방안에 관한 기초연구)

  • Kim, E-Wan;Lee, Jin-Woo;Lee, Chang-Hee;Yea, Byeong-Deok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.628-638
    • /
    • 2017
  • In response to difficult employment conditions in the maritime industry and a desire to expand their career options, domestic mates are persuing DP operator training at institutions both domestically and abroad based on their shipboard experience. However, since the offshore plant service industry has not yet been established in Korea, those seeking to enter this field have difficulty acquiring qualifications and most seek work overseas for offshore shipping companies. Individuals wishing to work as DP operators are likely to face more conservative recruitment processes with overseas offshore shipping companies, focusing on career language restrictions as they will be non-native speakers relative to the foreign company, difficulty living in a multi-cultural environment, and lack of systematic information on essential job requirements. For these reasons, domestic mates have difficulty seeking jobs. Therefore, this study analyzes the capabilities and qualification required to be a DP operator to provide basic data for developing NCS standards representing a minimum level of competency. These standards can be applied by the government to develop plans for professional training for DP operators. In study, job classifications, competency standards and career development paths for DP operators have been proposed along with joint use of DP training vessels, to train specialized DP instructors. An NCS export model led by the government to activate professional training for DP operators is also presented.

Spotlighting Engineering Service Business in Korea (각광받는 한국의 기술용역업)

  • Cho Kyu Shim
    • Proceedings of the Korean Professional Engineer Association Conference
    • /
    • 1987.12a
    • /
    • pp.65-71
    • /
    • 1987
  • All Korean professional engineer′s great joy Is to welcome the Japanese professional engineers and relevant guests to the 1987 Japan-Korea Professional Engineers Joint Convention organized by the Korean Professional Engineers Association. As there exists an effort of blood, sweat and tear behind a succeeded theatrical stage, so an exquisite devotion with drawing up a master plan, investigation, supervision and etc by engineering firms is soaked through every part of huge construction projects and large unit factory buildings. It is over 14 years that the Engineering Service Promotion Law has been enacted by the Ministry of Science and Technology. In the meantime, the domestic engineering (engineering service) have reached a remarkable higher level while the number of engineering firms participating in overseas market has gradually been increasing. From a small scale of under water investigation to a large scale planning of atomic reactor or petrochemical plant, engineering service business can be said "The Software of Total Industry." Engineering service is what is called a higher business which offers specialized engineering know-how and experience. Engineering service compaines offer Its specialized knowledge and experience to government, industry and commerce. Whether the task is to modernize plant equipment, to design a building or to manage construction, an engineering company will develop and implement the most appropriate and cost effective solution. Clients use the engineering service of firm knowing that the engineer′s professional judgement is not influenced or biased by other commercial affiliations. While benefiting from the diverse experience that professional engineers can apply to a specific problem, government and industry also reduce the need for permanent in-house engineering staff. Engineering firms may be specialized or multi-disciplinary.

  • PDF

Introduction of Vibration Evaluation for APR 1400 Reactor Coolant Pump Shaft (APR 1400급 원자로냉각재펌프의 회전체 진동평가에 관한 고찰)

  • Kim, Ik Joong;Lim, Do Hyun;Kim, Min Chul;Bang, Sang Youn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.110-115
    • /
    • 2014
  • The nuclear power plant was launched by Kori unit 1 in 1978 years. Currently, 23 nuclear power plants have been operating in Korea since 1978 years. The localization was completed for most of the reactor facility from Hanbit(Youngkwang) unit 3&4. However, RCP(Reactor Coolant Pump) and MMIS(Man Machine Interface System) is an important technology that has been excluded from the scope of the technical transfer has been dependent on a specific overseas vendor. Recent success in RCP development through co-operation with government and industries. Developed RCP will be applied to Shin-Hanul unit 1&2 nuclear power plants. The RCP operates in high speed and high pressure condition and only rotating component in the NSSS(Nuclear Steam Supply System). Therefore, the problem of vibration has arisen caused by the hydraulic forces of the working fluid. These forces can influence on the stability characteristics for entire RCS(Reactor Coolant System) loop, and can act as significant destabilizing forces. In this study, vibration evaluation of the pump shaft of development RCP estimated under normal operation and over speed conditions. In order to predict the vibration characteristics and dynamic behavior, modal analysis, critical speed analysis and unbalance response spectrum analysis were performed.

  • PDF

A Study on the Effect of. Oil Leakage for Soil Contamination, Plants and Groundwater (오일의 누출이 토양오염, 식생 및 지하수에 주는 영향에 관한 연구)

  • 진성기;도덕현;최규홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.1
    • /
    • pp.141-152
    • /
    • 1994
  • Our experiment investigated the degree of soil contaimination caused by oil leakage. Each soil sample was taken by boring 5, 8m below the test areas, located 5 to 30m from storage tanks at oil stations. According to the results from a series of laboratory tests(both soxhiet extract test and gas chromatograph test), Traces of a light oil were found in all samples except in Dj8, rocky soil and gasoline and petroleum were not detected. We concluded that soil contamination was caused by the corrosion of storage tanks or alternatively by oil overflow caused during the flooding of underground water seeping into the tank during heavy rain fall or the spillage caused by carelessness during lubrication. Old stations without a concrete box enclosing their metal tanks run a greater risk of oil leakage. To research the effect of oil leakage on plant growth and underground water, We examined the results of research conducted overseas. According to these results, when oil leakage occurs, plant growth is repressed and agricultural crops experience low productivity levels. Also, the contamination of underground water can be serious when oil spreads to the aquifer layer. As a result of these problems, to prevent oil leakage and minimize its contaminating effects at oil stations, it is necessary to improve facilities of storage tanks and have the monitoring system of oil leakage.

  • PDF

Full System Chemical Decontamination Concept for Kori Unit 1 Decommissioning (고리1호기 해체시 전계통 화학제염 운전개념)

  • Lee, Doo Ho;Kwon, Hyuk Chul;Kim, Deok Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.289-295
    • /
    • 2016
  • Kori Unit 1, the first PWR (Pressurized Water Reactor) plant in Korea, began its commercial operation in 1978 and will permanently shut down on June 18, 2017. After moving the spent fuels to SFP (Spent Fuel Pool) system, Kori Unit 1 will perform a full system chemical decontamination to reduce radiation levels inside the various plant systems. This paper will describe the operation concept of the full system chemical decontamination for Kori Unit 1 based on experiences overseas.

A Study on Architectural Form of Waste to Energy Plants in accordance with Law - Focus on Seoul and Tokyo - (법규에 따른 자원회수시설의 건축적 형태에 관한 연구 - 서울과 도쿄를 중심으로 -)

  • Jung, Seung-won;Lee, Kang-jun
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2022
  • Waste to Energy Plant were recognized as hateful facilities, and there were many conflicts in the location due to social problems such as the NIMBY phenomenon due to problems such as damage to property in the surrounding area, odor, and image loss. Problems such as air pollution and odor are solved by the development of advanced prevention facilities such as electric dust collectors, wet cleaning systems, semi-dry reaction towers, bag filters, and catalyst towers (SCR: Selective Catalytic Reduction), and air recycling facilities in waste storage tanks. However, it is being avoided because of the perception that it is an incinerator. To resolve these conflicts, the government installs and operates resident convenience facilities to compensate residents near resource recovery facilities, provides green space and improves the environment, and supports heating expenses in accordance with the 「Waste Treatment Facility Support Act」. The purpose of this study is to derive implications through the analysis of domestic and overseas case studies for resident convenience facilities and environment improvement for the promotion of local communities in resource recovery facilities and use them as basic data for community promotion and environmental improvement when installing resource recovery facilities in the future.