• Title/Summary/Keyword: Overload ratio

Search Result 88, Processing Time 0.026 seconds

A Non-Linear Overload Control Scheme for SIP Proxy Queues (SIP 프록시 큐의 비선형적 과부하 제어 방법)

  • Lee, Jong-Min;Jeon, Heung-Jin;Kwon, Oh-Jun
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.4
    • /
    • pp.43-50
    • /
    • 2010
  • Recently, the Internet telephony has been used rather than the traditional telephony by many Internet users, with low cost. Session Initiation Protocol(SIP) is the standard of application layer protocol for establishment and disconnection of the session for Internet telephony. SIP mainly runs over the UDP for transport. So in case of the loss of the INVITE request message, the message is retransmitted by an appropriate timer for reliable transmission of the UDP message. Though the retransmission is useful for ensuring the reliability of SIP messages sent by the users, it may cause the overload traffic in the SIP proxy server. The overload in SIP proxy servers results in the loss of many input messages. This paper presents a non-linear overload control algorithm to resolve the overload condition of the server. we simulate our proposed algorithm using the network simulator ns-2. The simulation results show that the throughput of the server with the proposed algorithm have been improved about 12% compared to the existing linear control algorithm.

Association between Transfusion-Related Iron Overload and Liver Fibrosis in Survivors of Pediatric Leukemia: A Cross-Sectional Study

  • Mahsa Sobhani;Naser Honar;Mohammadreza Fattahi;Sezaneh Haghpanah;Nader Shakibazad;Mohammadreza Bordbar
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.4
    • /
    • pp.215-223
    • /
    • 2024
  • Purpose: Patients who receive frequent blood transfusions are at an elevated risk of developing hepatic fibrosis due to iron overload in the liver. In this study, we evaluated the effectiveness of transient elastography (TE) (FibroScan®) for assessing liver fibrosis in patients with pediatric cancer. Methods: We enrolled 106 consecutive cases of acute leukemia in individuals under 21 years of age. The participants were followed for 2 years. Based on their serum ferritin (SF) levels, the patients were divided into two groups: group 1 (SF≥300 ng/mL) and group 2 (SF<300 ng/mL). A liver FibroScan® was performed, and a p-value of less than 0.05 was considered statistically significant. Results: Among the various parameters in the liver function test (LFT), alkaline phosphatase was significantly higher in a subgroup of patients aged 5-8 years in group 2 compared to those in group 1. The indices of liver fibrosis determined by TE, including the FibroScan score, controlled attenuation parameter score, steatosis percentage, and meta-analysis of histological data in viral hepatitis score, as well as indirect serum markers of liver fibrosis such as the aminotransferase (AST)/alanine aminotransferase (ALT) ratio, Fibrosis 4 score, and AST to platelet ratio index, did not differ significantly between the two groups. The association between the TE results and LFT parameters was only significant for ALT. Conclusion: Transfusion-associated iron overload does not have a significant correlation with severe liver fibrosis. FibroScan® is not a sensitive tool for detecting early stages of fibrosis in survivors of pediatric leukemia.

Crack Growth Behavior of Tensile Overload for Small Load Amplitude (하중진폭이 작은 인장과대 하중의 균열성장 거동)

  • 유헌일
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.2
    • /
    • pp.54-61
    • /
    • 1998
  • This paper examines the crack growth behavior of 7075-T651 aluminum alloy for small tensile overload under high-low block loading condition. The cantilever beam type specimen with a chevron notch is used in this study. The crack growth and closure are investigated by compliance method. The applied initial stress ratios are R=-0.5 R=0.0 and R=0.25 Crack length, effective stress intensity factor range, ratio of effective stress intensity factor range and crack growth rate etc, are inspected with fracture mechanics estimate.

  • PDF

Fatigue Crack Propagation Behaviors under the Controlloed Stress Amplitude (하중진폭제어에 따르는 피로균열전파거동)

  • Kim, Sang-Chul;Ham, Kyoung-Chun;Kang, Dong-Myeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.3
    • /
    • pp.140-148
    • /
    • 1992
  • The effect of mechanical, properties in the plastic zone near the crack-tip was investigated, under various controlled loading conditions, i.e., ${\Delta}K$ increasing, ${\Delta}K$ decreasing, and single overload test. For both ${\Delta}K$ decreasing test and ${\Delta}K$ increasing test with constant stress ratio, it is found that the ratio of material constant m'( ${\Delta}K$ decreasing test) to material constant m( ${\Delta}K$ increasing test) is larger than 1 for n<0.1, and it is equal to 1 for 0.10.2. A modified crack growth rate equation based on Forman's equation which applied stable region of fatigue crack propagation in ${\Delta}K$ decreasing test is proposed. Within the limit of this single overload test, an empirical relation between among the retardation ratio (Nd/ $N^{*}$), the strain hardening exponent (n) and the percent peak load (%PL) has been established.established.

  • PDF

A Study on Utilization Ratio and Operation of Transmission Lines (송전선로의 이용률 평가 및 합리적 운영에 관한 연구)

  • Kim, Dong-Min;Bae, In-Su;Cho, Jong-Man;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.426-432
    • /
    • 2006
  • This paper describes the concepts of Static Line Rating (SLR) and Dynamic Line Rating (DLR) and the computational methods to demonstrate them. Calculation of the line capacity needs the heat balance equation which is also used for computing the reduced tension in terms of line aging. SLR is calculated with the data from the worst condition of weather throughout the year. Even now, the utilization ratio is obtained from this SLR data in Korea. DLR is the improved method compared to SLR. A process for DLR reveals not only improved line ratings but also more accurate allowed line ratings based on line aging and real time conditions of weather. In order to reflect overhead transmission line aging in DLR, this paper proposes the method that considers the amount of decreased tension since the lines have been installed. Therefore, the continuous allowed temperature for remaining life time is newly acquired. In order to forecast DLR, this paper uses weather forecast models, and applies the concept of Thermal Overload Risk Probability (TORP). Then, the new concept of Dynamic Utilization Ratio (DUR) is defined, replacing Static Utilization Ratio (SUR). For the case study, the two main transmission lines which are responsible for the north bound power flow in the Seoul metropolitan area are chosen for computing line rating and utilization ratio. And then line rating and utilization ratio are analyzed for each transmission line, so that comparison of the present and estimated utilization ratios becomes available. Finally, this paper proves the validity of predictive DUR as the objective index, with simulations of emergency state caused by system outages, overload and so on.

Changes in Cytochrome c Oxidase and NO in Rat Lung Mitochondria Following Iron Overload

  • Kim, Min-Sun;Hong, Min-A;Song, Eun-Sook
    • Animal cells and systems
    • /
    • v.13 no.2
    • /
    • pp.105-112
    • /
    • 2009
  • In this study, the effects of iron on cytochrome c oxidase (CcO) in rat lung mitochondria were examined. Similar to liver mitochondria, iron accumulated considerably in lung mitochondria (more than 2-fold). Likewise, the reactive oxygen species and nitric oxide (NO) content of mitochondria were increased by more than 50% and 100%, respectively. NO might be produced by nitric oxide synthase (NOS), eNOS and iNOS type, with particular contribution by NOS in mitochondria. The respiratory control ratio of iron overloaded lung mitochondria dropped to nearly 50% due to increased state 4. Likewise, cytochrome c oxidase activity was lowered significantly to approximately 50% due to excess iron. Real-time PCR revealed that the expression of isoforms 1 and 2 of subunit IV of CeO was enhanced greatly under excess iron conditions. Taken together, these results show that oxidative phosphorylation within lung mitochondria may be influenced by iron overload through changes in cytochrome c oxidase and NO.

Element loss analysis of concentrically braced frames considering structural performance criteria

  • Rezvani, Farshad Hashemi;Asgarian, Behrouz
    • Steel and Composite Structures
    • /
    • v.12 no.3
    • /
    • pp.231-248
    • /
    • 2012
  • This research aims to investigate the structural behavior of concentrically braced frames after element loss by performing nonlinear static and dynamic analyses such as Time History Analysis (THA), Pushdown Analysis (PDA), Vertical Incremental Dynamic Analyses (VIDA) and Performance-Based Analysis (PBA). Such analyses are to assess the potential and capacity of this structural system for occurrence of progressive collapse. Besides, by determining the Failure Overload Factors (FOFs) and associated failure modes, it is possible to relate the results of various types of analysis in order to save the analysis time and effort. Analysis results showed that while VIDA and PBA according to FEMA 356 are mostly similar in detecting failure mode and FOFs, the Pushdown Overload Factors (PDOFs) differ from others at most to the rate of 23%. Furthermore, by sensitivity analysis it was observed that among the investigated structures, the eight-story frame had the most FOF. Finally, in this research the trend of FOF and the FOF to critical member capacity ratio for the plane split-X braced frames were introduced as a function of the number of frame stories.

Development of Power System Health Algorithm (전력계통 건전성 지수 알고리즘 개발)

  • Lim, Jin-Taek;Lee, Sung-Hun;Lee, Yeon-Chan;Choi, Jae-Seok;Choi, Hong-Seok;Joo, Joon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1328-1336
    • /
    • 2014
  • This paper proposes Power System Health Index(PSHI) newly. The paper describes several kind of power system health indices based on two main categories, which are adequacy and security. In adequacy, four kinds of health indices of Frequency, Voltage, Reserve(Operating Reserve Power and Frequency Regulation Reserve Power) and Overload of lines and transformers are proposed. In security, four kinds of health indices of Voltage(154kV, 345kV and 765kV), Overload of lines and transformers, Power flow constraint among areas and SPS are proposed. All indices are mapped with three domains, which are indicated as Health, Margin and Risk, defined with expert interview. While domains of health, margin and risk is defined similar with the conventional well being analysis of power system. The criterion of the domains is proposed using an interview with expert operators and practical reliability codes in Korea. The several kinds of health index functions, which are linear ratio, piecewise linear ration and reverse ratio function etc. are developed in this paper. It will be expected that the developed health indices can help operators to control power system more successfully and also prevent power system from accident as like as black out in future because operator can make a decision immediately based on more easily visual information of system conditions from too much indices acquisition of complex power system.

An Analysis of Driving Pattern and Transportation Efficiency of Commercial Vehicle using On-board Truck scale (자중계 적용을 통한 화물차량 운행패턴 및 운송효율성 분석)

  • Kim, Jong Woo;Jung, Young Woo;Jho, Youn Beom
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.76-95
    • /
    • 2019
  • An on-board truck scale is an essential technical solution for preventing overload, which makes the driver aware of the commercial vehicle weight. This study analyzed the effects of the driving pattern and transportation efficiency by the IoT Platform service for an on-board truck scale. A comparison of before and after installation using the long-term monitored data confirmed the reduction effects both of the overload ratio and overweight value, and their effects on increasing the transportation efficiency. In addition, the analysis result of the driving route showed that the installation of an on-board truck scale could be a more effective way of preventing overload than increasing the weighing checkpoints.

Effect of Low Temperature and Single Overload on Fatigue Crack Growth Behavior of Cr-Mo Steel Weldments (Cr-Mo강 용접부의 피로균열 성장거동에 미치는 저온도와 단일과대하중의 영향)

  • Lim, Jae Kyoo
    • Journal of Welding and Joining
    • /
    • v.14 no.2
    • /
    • pp.79-89
    • /
    • 1996
  • 일정진폭하중과 과대하중비 2.5의 단일 인장과대하중에 의한 4140강 용접부 의 피로균열성장거동을 실온과 -45.deg.C의 저온에서 피로시험과 파면관찰을 통하여 고찰하였다. 이때, 용접부 미시조직의 영향을 평가하기 위해 모재(parent metal), 열영향부(as-welded HAZ), 열처리된 열영향부(PWHT HAZ)로 나누어 응력비 0과 0.5로 CT시험편을 이용하여 피로시험을 실시하였다. 피로균열성장거동은 재료의 미시조직과 온도변화보다는 응력비에 크게 영향을 받았으며, 단일 과대하중에 의한 피로균열성장 지연효과가 모든 재료에서 상당히 크게 나타났다. 전자현미경에 의한 피로파면 관찰 결과, 실온에서는 연성의 스트라이에이숀과 -45.deg.C에서는 의벽개파면과 같은 피로 균열성장거동을 나타내고 있다.

  • PDF