• Title/Summary/Keyword: Overhead Transmission Wire

Search Result 37, Processing Time 0.028 seconds

Analysis of the inductive interference on the conductor around power system (송전선로 주위의 도체에 미치는 유도장해 해석)

  • Choi, Se-Yong;Nah, Wan-Soo;Choi, Myung-Jun;Lee, Se-Hee;Kim, Dong-Hun;Park, Il-Han;Shin, Myung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1034-1037
    • /
    • 1999
  • In this paper, we analyze the inductive interference in conductive material around power transmission line. To compute induced eddy currents as well as electromagnetic fields, finite element method(FEM) is used for numerical calculation. The characteristics of conductive material such as gas pipeline, overhead guide wires, conducting earth and so on are taken account of FEM analysis. This research also shows that mitigation wire reduces amount of eddy current in buried gas pipe line.

  • PDF

A Study on Lightning Surges in Underground Distribution Systems

  • Jung Chae-Kyun;Kim Sang-Kuk;Lee Jong-Beom
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.171-176
    • /
    • 2005
  • The effects of surge arresters for the protection of transmission systems against direct lightning strokes have already been reviewed by many researchers. However, their studies have not encompassed underground cable systems. Therefore, in this paper we investigate the 22.9kV combined distribution systems that have arresters and ground wires. In addition, we analyze the overvoltages on underground distribution cable sections when direct lightning strokes contact the overhead ground wire using EMTP. Finally, we discuss the effect of lightning strokes according to the change of cable length and installation of arresters. This study provides insulation coordination methods for reasonable system design in 22.9kV underground distribution cable systems.

Anomaly Detection using VGGNet for safety inspection of OPGW (광섬유 복합가공 지선(OPGW) 설비 안전점검을 위한 VGGNet 기반의 이상 탐지)

  • Kang, Gun-Ha;Sohn, Jung-Mo;Son, Do-Hyun;Han, Jeong-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.01a
    • /
    • pp.3-5
    • /
    • 2022
  • 본 연구는 VGGNet을 사용하여 광섬유 복합가공 지선 설비의 양/불량 판별을 수행한다. 광섬유 복합가공 지선이란, 전력선의 보호 및 전력 시설 간 통신을 담당하는 중요 설비로 고장 발생 전, 결함의 조기 발견 및 유지 관리가 중요하다. 현재 한국전력공사에서는 드론에서 촬영된 영상을 점검원이 이상 여부를 점검하는 방식이 주로 사용되고 있으나 이는 점검원의 숙련도, 경험에 따른 정확성 및 비용과 시간 측면에서 한계를 지니고 있다. 본 연구는 드론에서 촬영된 영상으로 VGGNet 기반의 양/불량 판정을 수행했다. 그 결과, 정확도 약 95.15%, 정밀도 약 96%, 재현율 약 95%, f1 score 약 95%의 성능을 확인하였다. 결과 확인 방법으로는 설명 가능한 인공지능(XAI) 알고리즘 중 하나인 Grad-CAM을 적용하였다. 이러한 광섬유 복합가공 지선 설비의 양/불량 판별은 점검원의 단순 작업에 대한 비용 및 점검 시간을 줄이며, 부가가치가 높은 업무에 집중할 수 있게 해준다. 또한, 고장 결함 발견에 있어서 객관적인 점검을 수행하기 때문에 일정한 점검 품질을 유지한다는 점에서 적용 가치가 있다.

  • PDF

Measurement of Transient Current by using the Rogowski Coil (로고우스키코일을 이용한 과도전류의 측정)

  • 이복희;길경석;정승수;정상진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1206-1213
    • /
    • 1994
  • This paper presents the operation principle and design rule of the Rogowski coil which can measure the transient current and describes the calibration and application experimental results for performance evaluation. It is obtained that the response curves of the Robowski coil with the turns of 300 and the passive integrator to sinusoidal input give a good linearity up to the frequency of 500 [kHz] and the current measurement system gaving the Rogowski coil is the frequency bandwidth of 40 [Hz]~700 [kHz]. As an application experiment for the fabricated modeling power transmission line, the impulse current, which limitates the direct lightning return stroke to overhead ground wire, is measured by the Rogowski coil and its fast Fourier transformation is carried out. The equivalent circuit of the Rogowski coil considering the stray capacitances is proposed, and the theoretical analysis is in good agreement with the measurement results. Also, it is found that for high frequency domain the stray capacitance such as a distributed capacitance to the shield and the capacitance between windings of coil should be considered in designing the Rogowski coils since the resonance originates from the stray capacitance and the self-inductance of the Rogowski coil.

  • PDF

Using Genetic Algorithms in Wireless Mesh Network Routing Protocol Design (유전 알고리즘을 이용한 무선 메쉬 네트워크에서의 라우팅 프로토콜 설계)

  • Yoon, Chang-Pyo;Ryou, Hwang-Bin
    • The KIPS Transactions:PartC
    • /
    • v.18C no.3
    • /
    • pp.179-186
    • /
    • 2011
  • Wireless Mesh Network technology refers to the technology which establishes wireless network whose transmission speed is similar to that of the wire system, and provides more enhanced flexibility in the building of network, compared to the existing wired network. In addition, it has the feature of less mobility and less restriction from the energy effect. However, there follow many considerations such as system overhead in the case of setting or the selection of multi-path. Accordingly, the focus is on the design and optimization of network which can reflect this network feature and the technology to establish path. This paper suggests the methods on the programming of path in Wireless Mesh Network routing by applying the evaluation value of node service, making use of the loss rate of data, the hop count of bandwidth and link and the traffic status of node, considering the performance of link and load in the fitness evaluation function, in order to respond to the programming of multi-path effectively.

Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology (전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.505-508
    • /
    • 2016
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace lines with high power impulse injection. Our proposed method uses to trace lines with very small power high frequency signal injection. Simulation models for 3-phase power transformers, 3-phase wire lines, and customer loads are described to investigate the transmission characteristics of high frequency power line carrier. Distribution lines have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires (삼상 다중 접지 배전계통에서 활선로 추적 방법)

  • Zheng, Yan-peng;Byun, Hee-Jung;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.559-562
    • /
    • 2017
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace off-lines with high power impulse injection. Our proposed method use to trace live lines with very small power high frequency signal injection. Typical power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. Two end communication terminals are required to be synchronized between them for determination on electrically same phases. Challenging issue is to achieve synchronization without GPS providing synchronizing time. A novel power transformer and wire identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF