• 제목/요약/키워드: Overhead Transmission Conductor

검색결과 77건 처리시간 0.03초

스페이서댐퍼 클램프의 선로방향 관절부와 서브스판진동과의 관계 실험적 고찰 (Experimental Study on the Relation Between the Longitudinal Articulation Part of a Spacer Damper and Subspan Oscillations)

  • 이형권
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.447-450
    • /
    • 2009
  • In order to protect conductors from oscillations or vibrations due to winds, spacer dampers are installed on overhead transmission lines. Generally the spacer damper clamp can move slightly according to oscillation directions, namely in longitudinal, vertical & horizontal directions. This is for reducing fatigue phenomena of the conductor. But the high longitudinal- displacement of the clamp raises a doubt for its necessity. Then this paper carried out oscillation tests by using 4 bundle test lines, to know the relation between longitudinal displacement and oscillation. and suggests design necessity of the longitudinal articulation part for spacer damper clamps.

시공유형에 따른 가공송전선 접속개소의 열적 특성 분석 연구 (The Study on Thermal Properties of Sleeve with Various Defects)

  • 안상현;김병걸;김상수;손홍관;박인표;김성규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.461-461
    • /
    • 2008
  • According to previous report, aged sleeves for old transmission lines have various defect such as biased installation or corrosion of steel sleeve. These defects occupied almost 50 percent of investigated aged sleeves. The defects have been limited power capacity of transmission line. And it can cause serious problems such as rapid increasing of sag or falling out of overhead conductor from sleeve. This paper study on thermal behavior of sleeve with various defect model. The detailed results were presented in the text.

  • PDF

철도 전차선의 보조전원을 위한 전력선 커플러 연구 (Study on Power Line Coupler for Auxiliary Power to Overhead Line)

  • 이건복;이경표;김명룡;이수길;창상훈
    • 한국전자파학회논문지
    • /
    • 제29권7호
    • /
    • pp.566-569
    • /
    • 2018
  • 철도 전차선 구조에 고주파 전력을 인가할 수 있는 전력선 커플러에 대해 분석하였다. 전차선 구조는 고압의 환경에서 보조전원을 공급하기가 어렵고, 먼 거리까지 전력을 전달하는 방법이 필요하다. 이를 위해 코어를 사용하지 않는 로고스키 코일에 공진을 활용하는 방법을 제안하였다. 조가선, 전차선, 드로퍼로 구성된 간이 전차선 구조를 제작하였고, 여러 사이즈의 커플러를 제작하여 조가선에 연결한 다음 일정 거리만큼 떨어진 두 커플러의 전달 특성을 비교하였다. 가장 성능이 좋은 커플러에 매칭 회로를 적용하여 측정한 결과, 2.5 m 거리에서 53 %의 전달 효율을 나타내었다. 제안하는 방법은 전차선과 같은 특수한 구조물에서 기존의 도선을 활용하여 보조전원을 인가할 수 있음을 보여준다.

HVAC 가공 송전선로 환경친화설계프로그램 TLCALC (Environmentally Friendly Design Program for HVAC Overhead Transmission Lines)

  • 양광호;주문노;명성호;신구용;이성두;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.67-70
    • /
    • 2005
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environment design software, TLCALC 2001 for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient. TLCALC 2001 solved a few problems in use of the existing foreign tools and took several advantages. Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC 2001 is easy and practical, this program will be usefully applied to the environmental friendly design and construction of HVAC transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC 2001.

  • PDF

HVAC 가공 송전선로 환경친화설계프로그램 개발 (Development of an Environmental Friendly Design Program for HVAC Overhead Transmission Lines)

  • 양광호;주문노;명성호;신구용;이성두;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.469-471
    • /
    • 2002
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environment design software, TLCALC 2001 for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient TLCALC 2001 solved a few problems in use of the existing foreign tools and took several advantages. Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC 2001 is easy and practical, this program will be usefully applied to the environmental friendly design and construction of HVAC transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC 2001.

  • PDF

Spectral element method in the analysis of vibrations of overhead transmission line in damping environment

  • Dutkiewicz, Maciej;Machado, Marcela
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.291-303
    • /
    • 2019
  • In the paper the analysis of natural vibrations of the transmission line with use of spectral elements and the laboratory experiments is performed. The purpose of the investigation is to analyze the natural vibrations of the transmission line and compare with the results obtained in the numerical simulations. Particular attention is paid to the hysteretic and aerodynamic damping analysis. Sensitivity of the wave number is performed for changing of the tension force, as well as for the different damping parameters. The numerical model is made using the Spectral Element Method. In the spectral model, for various parameters of stiffness, damping and tension force, the system response is checked and compared with the results of the accelerations obtained in the measurements. A frequency response functions (FRF) are calculated. The credibility of the model is assessed through a validation process carried out by comparing graphical plots of FRF and time history analysis and numerical values expressing differences in acceleration amplitude (MSG), phase angle differences (PSG) and differences in acceleration and phase angle total (CSG) values. The next aspect constituting the purpose of this paper is to present the wide possibilities of modelling and simulation of slender conductors using the Spectral Element Method. The obtained results show good accuracy in the range of both experimental measurements as well as simulation analysis. The paper emphasizes the ease with which the sensitivity of the conductor and its response to changes in density of spectral mesh division, tensile strength or material damping can be studied.

지중송전케이블룡 디지털 거리계전 알고리즘 개선 (An Improvement of Digital Distance Relaying Algorithm on Underground Transmission Cables)

  • 하체웅;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권12호
    • /
    • pp.595-601
    • /
    • 2000
  • This paper describes the improvement method of distance relaying algorithm for the underground transmission cables. Distance relaying algorithms have been mainly developing to protect the overhead transmission lines than the underground cables. If the cable systems are directly protected using distance relaying algorithm developed for overhead line without any improvement, there will be really occurred many misoperation in cable systems, because the cable systems consist of the conductor, the sheath, several grounding method, cable cover protection units(CCPUs), and grounding wire. Accordingly, the complicated phenomena are occurred, if there is a fault in cable systems. Therefore, to develope a correct distance relaying algorithm, such cable characteristics should be taken into account. This paper presents the process to improve distance relaying algorithm which is now used. REal cable system was selected to establish modeling in EMTP and ATP Draw. It was discovered through the detailed simulation during the fault that the large error existed between impedance measured at the relay point and real impedance is due to the resistance of grounding wire in each grounding method. And also compensation factor obtained by the simulation is proposed in this paper. It is proved that the factor proposed can fairly improve the accuracy of impedance at the relay point. It is evaluated that the protective ability will be really much improved, if the algorithm proposed in this paper is applied for cable systems of utility.

  • PDF

적응 뉴로퍼지 추론시스템을 이용한 가공 송전선의 열화등급 진단 (Diagnosis of Deterioration Grades for Overhead Transmission Lines using Adaptive Neuro-Fuzzy Inference System)

  • 김성덕;이상래
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.57-63
    • /
    • 2003
  • 가공 송전선로의 아연도금 강심 알루미늄연선 도체들은 장기간 동안 대기오염에 의해 서서히 열화되었기 때문에, 2천년 대에 이르러 수많은 도체들이 예상된 유효수명을 초과하였다. 대부분의 도체들은 경제적인 운용 측면에서 현재 상태들을 평가하지 않으면 안되므로, 이 논문에서는 경년, 환경지표, 및 도체구조와 같은 중요 파라미터들을 사용하여 노화도체의 현재 상태를 평가하기 위한 방법을 제안하였다. 노화도체의 수명에 대응하는 열화등급을 예측하기 위한 진단 방법을 기술하였으며, 이 시스템은 전문가 지식과 경험을 토대로 적응 뉴로퍼지 추론시스템 (Adaptive Neuro-Fuzzy Inference System)으로 설계하였다. 이 진단시스템을 국내의 송전선로에 적용하여, 이 시스템이 노화 ACSR 도체를 비파괴적으로 진단하고 경제적으로 운용하기 위한 방안으로서 효과적으로 사용될 수 있음을 밝혔다.

산불에 노출된 가공송전선의 열화특성연구

  • 장용호;김병걸;김상수;한세원;이원교
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.282-282
    • /
    • 2009
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very important to maintain transmission line safely. Specimenes for this study were Al conductores of ACSR $410mm^2$, ACSR 480 R and ACSR $240mm^2$. This paper describes the changes of mechanical and electrical properties of same flame exposed Al conductor. The detailed will be given in the text.

  • PDF

지중송전케이블 뇌서지 유도현상 분석 (Analysis of Induced Lightning Surge Phenomena on Underground Power Cables)

  • 정채균;강연욱;강지원;김두진;김재승;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.578-579
    • /
    • 2011
  • This paper describes the analysis of induced lightning surge phenomena at underground power cables under construction when the lightning surge strikes at phase conductor of grounding wire of overhead line in service. Therefore, This paper proposes the optimal protection methods establishment against lightning surge induced from operating transmission.

  • PDF