• Title/Summary/Keyword: Overdentures

Search Result 80, Processing Time 0.03 seconds

Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading

  • Tavakolizadeh, Sara;Vafaee, Fariborz;Khoshhal, Masume;Ebrahimzadeh, Zahra
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.191-198
    • /
    • 2015
  • PURPOSE. The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures. MATERIALS AND METHODS. Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch's category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups. RESULTS. All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was $0.6{\pm}0.67$ mm in the first group and $0.6{\pm}0.51$ mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups. CONCLUSION. This preliminary one-year result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.

Comparison of changes in retentive force of three stud attachments for implant overdentures

  • Kim, Su-Min;Choi, Jae-Won;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.303-311
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS. Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting. Five pairs of each attachment system were tested. A universal testing machine was used to measure the retentive force during 2500 insertion and removal cycles. Surface changes on the components were evaluated by scanning electron microscopy (SEM). A Kruskal-Wallis test, followed by Pairwise comparison, was used to compare the retentive force between the groups, and to determine groups that were significantly different (${\alpha}$<.05). RESULTS. A comparison of the initial retentive force revealed the highest value for Kerator, followed by the O-ring and EZ lock attachments. However, no significant difference was detected between Kerator and O-ring (P>.05). After 2500 insertion and removal cycles, the highest retention loss was recorded for O-ring, and no significant difference between Kerator and EZ lock (P>.05). Also, Kerator showed the highest retentive force, followed by EZ lock and O-ring, after 2500 cycles (P<.05). Based on SEM analysis, the polymeric components in O-ring and Kerator were observed to exhibit surface wear and deformation. CONCLUSION. After 2500 insertion and removal cycles, all attachments exhibited significant loss in retention. Mechanism of retention loss can only be partially explained by surface changes.

Retreatment of implant overdenture using Milled Bar and Attachment in a patient using a unilateral prosthetic arm: A case report (편측 의수 사용 환자에서 Milled Bar와 Attachment를 이용한 임플란트 피개의치 재수복 증례)

  • Park, So-Hyung;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, So-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.187-194
    • /
    • 2022
  • The use of implants could improve the support, retention, and stability of removable prosthetic restoration for fully edentulous patients with severe alveolar bone resorption. When the prosthesis is manufactured without accurate diagnosis and evaluation, this may lead to unfavorable treatment result. The patient in this case had the treatment of implant overdentures at a private dental clinic, but visited the hospital for retreatment due to soft tissue pain and decreasing retention of existing dentures. The vertical dimension was raised compared to the existing dentures, and overdentures were manufactured using milled bars and additional attachments. The clinical results were satisfactory in the aspect of improved oral hygiene maintenance, function and esthetics.

Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures

  • Esra Nur Avukat;Canan Akay;Emre Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.214-226
    • /
    • 2023
  • PURPOSE. This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. MATERIALS AND METHODS. A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. RESULTS. It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. CONCLUSION. Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction.

Detachable zirconia prosthesis using Milled bar and ADD-TOC attachment in partial edentulous mandible: A case report (하악 부분 무치악 환자에서 Milled-bar와 ADD-TOC 부착 장치를 이용한 탈착 가능한 지르코니아 보철물 수복 증례)

  • Min-Sung Sohn;Jung-Bo Huh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.90-99
    • /
    • 2023
  • Implant overdentures are widely used as a treatment method to restore oral function in completely edentulous or partially edentulous patients with severe bone resorption. Using a milled bar, it is mechanically advantageous as the implant fixtures are splinted. Applying additional attachments to the bar has the advantage of dispersing the stress applied to the implant. In this case, a patient who used implant overdentures using 4 implants wanted to fabricate a new prosthesis due to repeated fractures of the denture and weakened retention. Milled bar with ADD-TOC attachment and zirconia prosthesis were fabricated by CAD-CAM method and mechanically and aesthetically satisfactory results were obtained.

OVERDENTURES AND OSSEOINTEGRATED IMPANTS (오버덴춰와 골융합성 임프란트)

  • Shin Sang-Wan;Suh Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.197-203
    • /
    • 1991
  • 저작압을 골에 직접 분산시키고 의치를 직접 골에 부착시켜 의치의 안정성을 증진시키는 가능성을 실현하는 것이 오랫동안 보철과의사들의 목표였다. 수십년 동안 골과 티타늄 임프란트가 결합(적합)되는 골융합성 술식이 발전되어 왔으며 이 임프란트의 상부구조물로 고정식 보철물이 받아들여져 왔다. 현재까지 가장 흔한 상부구조는 고정식 보철물이다. 요즈음 골융합성 임프란트에 지지를 받는 오버 덴춰의 술식이 고정식 보철물과 다른 하나의 방법으로 간주되어질 수 있게 되었다. 오버덴춰 술식이 심미적 경제적 이유 그리고 다양하게 적용할 수 있기 때문에 최근에 확대되는 경향이 있다. 골융합성 임프란트에 의한 고정식 보철물에 대한 광범위한 장기 결과들이 있는데 반하여 여러 어태치먼트를 이용한 오버덴춰 술식은 임상결과나 적용에 과한 지식들이 거의 발표되지 않았으며, 현재까지 임프란트 오버덴춰를 가진 환자의 구강기능에 대한 단지 몇개의 연구들만이 발표되었다. 우리는 장기 임상평가에 의해서 임프란트 오버덴춰를 아주 조심스럽게 평가해야 한다.

  • PDF

CASE REPORTS ON THE MAGNETIC RETAINED OVERDENTURES (자석 유지장치를 이용한 Overdenture 수복에 관한 임상적 연구)

  • Vang Mong-Sook;Choi Chang-Hwan;Kim Young-Yi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.88-97
    • /
    • 2002
  • The purpose of this study was to evaluate a cases which was treated with magnetic attachments on the patients in edentulous mandible and maxilla. Author made magnetic overdenture for two patients and then clinical examination were used for evaluation of the function and change in retention during 30months. Patients showed difficulty in oral hygiene care at the beginning but they go used to it soon. It was effective in promotion of denture retention and stability and also gave patient emotionally uplifting psychologic state. This study suggest that magnetic attachment was effective for the treatment of patients presenting a few remaining teeth or teeth under severe caries or mobility.

Prosthetic management of a growing patient with Russell-Silver syndrome: a clinical report

  • Kim, Kanghyun;Noh, Kwantae;Paek, Janghyun;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.406-410
    • /
    • 2015
  • Russell-Silver syndrome (RSS) is a congenital disease characterized by short stature due to growth hormone deficiency, physical asymmetry, inverted triangular face, micrognathia, prominent forehead, and hypodontia. This case report presents a prosthetic management of a 6-year-old patient with Russell-Silver syndrome treated with overdentures on the maxilla and the mandible using the remaining primary teeth. Subsequent and comprehensive dental management considering the growth and development of a young patient will be necessary.

Mandibular Mini-Implants Supported Overdentures: A Case Report (미니 임플란트를 이용한 하악의 임플란트 지지 피개의치: 증례보고)

  • Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • Implantology
    • /
    • v.19 no.3
    • /
    • pp.146-152
    • /
    • 2015
  • Mini-dental implants for overdenture applications are increasingly popular due to their ease in placement with simplified, less traumatic surgical protocols in limited-width alveolar ridges. However, the clinical decisions including implant number, position, and loading protocol must be based on a thorough evaluation and evidence-based diagnosis. Herein, we reported a case treated with the current method of mandibular mini-implant supported overdenture.

A FEM study on stress distribution of tooth-supported and implant-supported overdentures retained by telescopic crowns (텔레스코픽 크라운 임플란트 지지 피개의치와 치아 지지 피개의치의 하악골내 응력분포에 관한 유한요소분석)

  • Paek, Jang-Hyun;Lee, Chang-Gyu;Kim, Tae-Hun;Kim, Min-Jung;Kim, Hyeong-Seob;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.10-20
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress distribution in mandibular implant-supported overdentures and tooth-supported overdentures with telescopic crowns. Materials and methods: The assumption of this study was that there were 2, 3, 4 natural teeth and implants which are located in the second premolar and canine regions in various distributed conditions. The mandible, teeth (or implants and abutments), and connectors are modeled, and analyzed with the commercial software, ANSYS Version 10.1. Stress distribution was evaluated under 150 N vertical load bilaterally on 3 experimental conditions - between canine areas, canine and $2^{nd}$ premolars, 10 mm posterior to $2^{nd}$ premolars. Results: Overall, the case of the implant group showed more stress than the case of the teeth group in stress distribution to bone. In stress distribution to superstructures of tooth and implants, there was no significant difference between TH group and IM group and the highest stress appeared in TH-IV and IM-IV. The stress caused from bar was much higher than those of implant and tooth. TH group showed less stress than IM group in stress distribution to abutment teeth and implant. Conclusion: The results shows that it is crucial to make sure that distance between impact loading point and abutment tooth does not get too far apart, and if it does, it is at best to set abutment tooth on premolar tooth region. It will be necessary to conduct more experiments on effects on implants, natural teeth and bone, in order to apply these results to a clinical treatment.