• Title/Summary/Keyword: Over-load

Search Result 2,147, Processing Time 0.029 seconds

An Antenna-Integrated Oscillator Design Providing Convenient Control over the Operating Frequency and Output Power (동작주파수 및 출력파워 조절이 용이한 신호생성용 안테나 설계)

  • Lee, Dong-Ho;Lee, Jong-In;Kim, Mun-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • A new design for easily controlling operating frequency of an antenna-integrated planar oscillator is introduced. The oscillator circuit of a broadband negative-resistance active part and a passive load including a patch antenna. The patch resonance is used for determining the oscillation frequency. This design reduces the possibility of mismatch between antenna radiation and oscillation frequencies. To achieve optimum output power, load-pull simulation for the negative-resistance circuit is used. The load-pull simulation shows the feed point and the delay of feed line can affect the oscillation power. Two negative-resistance circuits capable of supporting oscillation over full C-band and X-band are fabricated. The oscillation frequency, output power and phase noise for different patch antennas are measured.

  • PDF

Settlement Behavior of Strip Foundation on Geogrid Reinforced Clay under Cyclic Loading (Geogrid로 보강된 점토지반에 축조된 대상기초의 반복하중하에서의 침하거동)

  • 신은철;다스브라지앰
    • Geotechnical Engineering
    • /
    • v.11 no.3
    • /
    • pp.27-36
    • /
    • 1995
  • Laboratory model tests to determine the permanent settlement of a surface strip foundati on supported by geogrid -reinforced saturated clay and subjected to a low -frequency cyclic load were performed. In conducting the test, the foundation was initially subjected to an allowable static load. The cyclic load was then super -imposed over the static load. The variation of the maximum permanent settlement with the intensity of the static load and the intensity of the amplitude of the cyclic load are also presented.

  • PDF

A Configuration of DLC(Direct Load Control) Using TCP/Ethernet Module And Load Control Method ( I ) (TCP/Ethernet방식을 이용한 DLC(Direct Load Control)의 구성 및 부하제어기법 ( I ))

  • Kim, Hyong-Joong;Kim, In-Soo;Park, Kyu-Hyu;Cha, Yang-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.570-572
    • /
    • 2000
  • In this paper, we present the configuration of Direct Load Control System using TCP/Ethernet Module for the Load Management Europe and America has operated the DLC system by many communication system, and Taiwan, Japan has controlled the cooling load at peak hours of power system. Up to now, Many Researches for the DLC of communication method, so called, pager, power line carrier, ripple control, etc. has advanced. Now, we present new communication method for the DLC using TCP/Ethernet module which is widespread all over the world.

  • PDF

Design of VML-based Game System for Dynamic Load Balancing (동적 부하 분산을 위한 VML 기반 게임 시스템 설계)

  • Lee, Jeong-Jin;Won, Dong-Kee;Hwang, Ho-Jeon;Doo, Gil-Su;Kim, Beob-Kyun;An, Dong-Un;Chung, Seung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.303-305
    • /
    • 2005
  • In MMORPG, gamers can engage in a variety of activities with other players from all over the world. So, this kind of games has unprecedented heavy load. There are so many kind of method to balance the load of MMORPG. But. many of them are not adaptable to dynamic load variation. In this paper, we propose a dynamic map-partition method based on VML. By use of dynamic map-partition based on VML, we can easily adapt to dynamic load variation. And by changing VML. we can manage field servers within game system.

  • PDF

Observer Based Estimation of Driving Resistance Load for Vehicle Longitudinal Motion Control

  • Kim, Duk-Ho;Shin, Byung-Kwan;Kyongsu Yi;Lee, Kyo-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.185-188
    • /
    • 1999
  • An estimation algorithm for vehicle driving load has been proposed in this paper. Driving load is an important factor in a vehicle's longitudinal motion control. An approach using an observer is introduced to estimate driving load based on inexpensive RPM sensors currently being used in production vehicles. Also, a torque estimation technique using nonlinear characteristic functions has been incorporated in this estimation algorithm. Using a nonlinear full vehicle simulation model, we study the effect of the driving load on longitudinal vehicle motion, and the performance of the estimation algorithm has been evaluated. The proposed estimation algorithm has good performance and robustness over uncertainties in the system parameters. An accurate estimate of the driving load can be very helpful in the development of advance vehicle control systems such as intelligent cruise control systems, CW/CA systems and smooth shift control systems.

  • PDF

Digital Positioning Control of Pneumatic Cylinder System with Elastic and Viscous Load (탄성 및 점성 부하시 공기압 실린더 시스템의 디지털 위치 제어)

  • 박명관;문영진;편창관
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.137-144
    • /
    • 1998
  • For a model system consisted of four pneumatic cylinders with strokes of 10, 20, 40 and 80 mm, investigation was carried out experimentally and numerically about the reliability of system with elastic and viscous load. The elastic load affects the performance of each cylinder in cylinder series, and changes the time lag and the velocity of the piston which makes the positioning control rather difficult. Taking the effects of the elastic load into consideration, positioning can be carried out comparatively smoothly by only adjusting the driving timing. The effect of a viscous load reduces the vibration of each moving body in the cylinder series and also reduces the over-travelled distance which happens when several cylinders move at the same time. For reasons, a positioning with a viscous load can be relatively smoothly carried out even without the timing control.

  • PDF

Stochastic Analysis of the Uncertain Hourly Load Demand Applying to Unit Commitment Problem (발전기 기동정지 계획에 적용되는 불확실한 부하곡선에 대한 통계적 분석)

  • Jung, Choon-Sik;Park, Jeong-Do;Kook, Hyun-Jong;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.337-340
    • /
    • 2000
  • In this paper, the effects of the uncertain hourly load demand are stochastically analyzed especially by the consideration of the average over generation of the Unit Commitment(UC) results. In order to minimize the effects of the actual load profile change, a new UC algorithm is proposed. The proposed algorithm calculates the UC results with the lower load level than the one generated by the conventional load forecast. In case of the worse load forecast, the deviation of the conventional UC solution can be overcome with the lower load level and the more hourly reserve requirements. The proposed method is tested with sample systems, which shows that the proposed method can be used as the basic guideline for selecting the potimal load forecast applying to UC problem.

  • PDF

Validity Examination on Evaluation of J-R Curve in the Nuclear Reactor Pressure Vessel Steels and Aluminum Alloys by Load Ratio Analysis (원자로 압력용기강 및 Al 합금재의 J-R곡선평가시 Load Ratio 해석의 유효성 검토)

  • Yoon, H.K.;Woo, D.H.;Kim, Y.K.;Cha, G.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.80-90
    • /
    • 1997
  • The purpose of this study is to evaluate the validity examination of the J-R curve characteristics for the nuclear reactor pressure vessel steels and Al alloys by the load ratio analysis. The results of the load ratio analysis are compared with those of the J-R curve which are obtained by the ASTM unloading compliance method. The crack length calculated by the load ratio analysis is agree well with the measured final crack length. The slope of the exponential J-R curve estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method. The J-R curve obtained by the ASTM unloading compliance method is over-predicted and should be offsetted due to the initial negative crack. On the other hand, the load ratio analysis method can evaluate the J-R curve by only load-displacement curve without particular crack measurement equipment.

  • PDF

대구경 소켓경사반력말뚝의 인발거동에 관한 연구

  • 최용규;김상옥;정창규;정성기;김상일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.277-284
    • /
    • 2000
  • Using the large diameter (D = 2,500mm, L = 40m) batter steel pipe piles, designed as compression piles but used as reaction piles during the static compression load test of socketed test piles (D = 1,000mm, L = 40m), static pile load tests for large diameter instrumented rock-socketed piles were performed. The reaction steel pipe piles were driven 20m into the marine deposit and weathered rock layer and then l0m socketed with reinforced concrete through the weathered rock layer and into hard rock layer. Steel pipe and concrete in the steel pile part, and concrete and rebars in the socketed parts were instrumented to measure strains in each part. The pullout amounts of reaction pile heads were also measured with LVDT. During the static pile load test, total compressional load of about 20MN was loaded on the head of test piles, but load above 20MN was not loaded due to lack of loading capacity of loading system. Over the course of the study, maximum pullout amount up to 7mm was measured in the heads of reaction piles when loaded op to 10MN and 1mm of pullout amount was measured. More than 85% of pullout load was transfered in the residual weathered rock layer and about 10% in the soft rock layer, which was somewhat different transfer mechanism in the static compressional load tests.

  • PDF

The Analysis of Low Back Loading and Muscle Fatigue while Lifting an Asymmetric Load (비대칭무게중심을 지닌 물체 들기 작업시 허리부위 등근육 부하 및 피로 분석)

  • Han, Seung-Jo;Kim, Sun-Uk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.30-36
    • /
    • 2012
  • This study is aimed to show that an asymmetric load in the frontal plane leads to an increase in low back loading and fatigue in comparison with a symmetric load when workers lift an external weight by investigating previous studies and verifying the phenomenon with an experiment. Ten male subjects are required to lift and hold an given external load at 70cm height during 50sec, then the EMG amplitude and median frequency on bilateral low back muscle groups (Longissimus, Iliocostalis, and Multifidus) are recorded and analyzed. Independent variables are two-level load weight (13kg, 20kg) and three-level LCG (Center, 6.5cm to the right, and 13cm to the right), and dependent variables are EMG amplitude average, difference, and Fatigue Index (FI). Results show that load weight increases significantly amplitude average and FI, but LCG does significantly amplitude difference and FI significantly (P-value < 0.05). Also the correlation coefficient between amplitude difference and FI is over 0.99. These implies that trunk loading should be explained by not EMG amplitude but muscle fatigue aspect since the association between an external load and amplitude is linear, but the relationship between an external load and median frequency as muscle fatigue index is almost exponential.