• 제목/요약/키워드: Over load test

검색결과 470건 처리시간 0.025초

건축물에너지 효율을 위한 조적조 열교 차단 브라켓의 성능 평가 연구 (A Study on Performance Evaluation of Masonry Thermal Bridge Blocking Brackets for Building Energy Efficiency)

  • 김웅회;김형규;이태규;이재현;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2023
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware(connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. As a result of the evaluation, it was confirmed that the performance was improved compared to the existing bracket, and we plan to carry out a real-life test and long-term performance review of the building using the bracket in the future.

  • PDF

Experimental and analytical study on improvement of flexural strength of polymer concrete filled GFRP box hybrid members

  • Ali Saribiyik;Ozlem Ozturk;Ferhat Aydin;Yasin Onuralp Ozkilic;Emrah Madenci
    • Steel and Composite Structures
    • /
    • 제50권4호
    • /
    • pp.475-487
    • /
    • 2024
  • The usage of fiber-reinforced polymer materials increases in the construction sector due to their advantages in terms of high mechanical strength, lightness, corrosion resistance, low density and high strength/density ratio, low maintenance and painting needs, and high workability. In this study, it is aimed to improve mechanical properties of GFRP box profiles, produced by pultrusion method, by filling the polymer concrete into them. Within the scope of study, hybrid use of polymer concrete produced with GFRP box profiles was investigated. Hybrid pressure and bending specimens were produced by filling polymer concrete (polyester resin manufactured with natural sand and stone chips) into GFRP box profiles having different cross-sections and dimensions. Behavior of the produced hybrid members was investigated under bending and compression tests. Hollow GFRPxx profiles, polymer-filled hybrid members, and nominative polymeric concrete specimens were tested as well. The behavior of the specimens under pressure and bending tests, and their load bearing capacities, deformations and changes in toughness were observed. According to the test results; It was deduced that hybrid design has many advantages over its component materials as well as superior physical and mechanical properties.

상태지수의 경향성 분류에 기반한 풍력발전기 베어링 잔여수명 추정 (Estimation of Remaining Useful Life for Bearing of Wind Turbine based on Classification of Trend)

  • 서윤호;김상렬;마평식;우정한;김동준
    • 풍력에너지저널
    • /
    • 제14권3호
    • /
    • pp.34-42
    • /
    • 2023
  • The reduction of operation and maintenance (O&M) costs is a critical factor in determining the competitiveness of wind energy. Predictive maintenance based on the estimation of remaining useful life (RUL) is a key technology to reduce logistic costs and increase the availability of wind turbines. Although a mechanical component usually has sudden changes during operation, most RUL estimation methods use the trend of a state index over the whole operation period. Therefore, overestimation of RUL causes confusion in O&M plans and reduces the effect of predictive maintenance. In this paper, two RUL estimation methods (load based and data driven) are proposed for the bearings of a wind turbine with the results of trend classification, which differentiates constant and increasing states of the state index. The proposed estimation method is applied to a bearing degradation test, which shows a conservative estimation of RUL.

A Study on Hydrodynamic Stiffness Characteristics of Air Bearing for High Speed Spindle

  • Lee, J.Y.;Lee, D.W.;Seong, S.H.;Lee, Y.C.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.115-116
    • /
    • 2002
  • This study was carried out as one of efforts to overcome difficulties in air bearing design due to low stiffness and low damping. Hydrodynamic effects on hydrodynamic stiffness of a fluid film in a high speed air bearing with tow-row air sources are investigated. The hydrodynamic effects by the high speed over DN 1,000,000 and eccentricity of a proceeding which are not considered in conventional design of an air bearing need to be reconsidered. The hydrodynamic effects, which dominantly influence on the load capacity of air bearing, are caused mainly by proceeding speed, eccentricity, and the source positions. The two-row source arrangement in the air bearing produces quite unique hydrodynamic effects with respect to pressure distribution of the air film. Optimal arrangement of the two-row sources improves performance of an air bearing in film reaction force and loading capacity of high speed spindles. This study compares the pressure distribution by numerical simulation as a function of eccentricity of proceeding and the source positions. The air source position 1/7L form one end of an air bearing was found to be superior to source position of 1/4L. The dynamic stiffness were obtained using a two-dimensional cutting method which can directly measure the cutting reaction forces and the displacements of the spindle in two directions using a tool dynamometer and transducer sensors. Heat generation in the air film can not be negligible over the speed of DN 2,000,000. In order to analysis effects of heat generation on the characteristics of air bearing, high cooling bearing spindle and low cooling bearing spindle were tested and compared. Characteristics of the frequency response of shaft and motion of run out errors were different for the spindle. The test results show that, in the case of low cooling bearing spindle, the stiffness became smaller due to heat generation. The results, which were obtained for high speed region, may be used as a design information for spindle which can be applied to precision devices such as ultra precision grinding and ultra high speed milling.

  • PDF

접촉 불량에 의한 불꽃 및 직렬아크의 검출 기법에 관한 연구 (A Study on the Detection Technique of the Flame and Series arc by Poor Contact)

  • 김현우;백동현
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.24-30
    • /
    • 2012
  • 본 연구는 저압 선로의 접촉 부분에서 발생할 수 있는 접촉 불량과 그 부분의 진동이 결합될 경우 발생될 수 있는 불꽃 및 직렬 아크를 검출할 수 있는 방법에 대한 것이다. 일반적으로 전기화재의 원인은 과전류, 단락, 접촉불량 등 여러 가지가 있을 수 있다. 이 중 과전류 및 단락 등은 선로에 흐르는 순간 전류량을 검출하여 감지할 수 있으나, 접촉불량은 전압, 전류값의 초과분 및 파형의 왜곡으로는 검출하기가 어려운 점이 있다. 따라서 본 논문에서는 퍼지논리 및 다차원 기법을 이용하여 최적의 아크 판단 기법을 연구하고, 아크 검출 및 검증을 위한 모의실험과 제어기 실험 및 부하실험을 실시하였다. 그 결과 제어기 및 검출 알고리즘이 여러 가지 부하와 상관없이 정상적인 부하의 파형과 아크 발생시의 파형을 구분하여 성공적으로 직렬아크를 검출하였다.

Relationship of Oral Bacterial Load Over One Year of Smoking Cessation

  • Kim, Sunghyun;Seo, Min-Seock;Hwang, Soo-Jeong
    • 치위생과학회지
    • /
    • 제19권4호
    • /
    • pp.213-219
    • /
    • 2019
  • Background: Smoking exerts an adverse effect on the periodontal tissue by reorganizing the ecosystem of oral microorganisms and is considered to be an important factor in the development of periodontal disease. Although cross-sectional studies on smokers and non-smokers have been attempted to investigate the microbial differences in periodontal oral cavity, only few studies have been conducted to investigate the changes in oral microorganisms during smoking cessation. The purpose of this study was to investigate the changes of bacteria in saliva and gingival crevicular fluid (GCF) over a period of one year among 11 smokers trying to quit smoking. Methods: Eleven smokers trying to quit smoking visited the clinic at baseline, two weeks, two months, four months, six months, and 12 months to give saliva and GCF samples. The amounts of 16S rRNA, Porphyromonas gingivalis, Treponema denticola, Prevotella intermedia, Fusobacterium nucleatum subsp. nucleatum, Streptococcus mutans, and Streptococcus sobrinus in saliva and GCF were quantified using real-time polymerase chain reaction TaqMan probe assay. The results were analyzed by nonparametric statistical analysis using Friedman test and Spearman correlation coefficient. Results: After cessation of smoking, the amounts of 16S rRNA corresponding to P. gingivalis, F. nucleatum, P. intermedia, and T. denticola in saliva decreased and then again increased significantly. The amount of F. nucleatum 16S rRNA in GCF decreased significantly after smoking cessation. Positive correlations were observed between 16S rRNA and F. nucleatum and between F. nucleatum and T. denticola in saliva and GCF. Conclusion: Even if the number of subjects in this study was small, we suggest that smoking cessation may reduce the total bacterial amount and F. nucleatum in GCF. However, the results regarding changes in the microbial ecosystem due to smoking or smoking cessation were inconsistent. Therefore, further in-depth studies need to be carried out.

초기재령에서 콘크리트 인장균열에 대한 쌍선형 응력-균열 개구 관계의 변화 (Variation of Bilinear Stress-Crack Opening Relation for Tensile Cracking of Concrete at Early Ages)

  • 권승희;최강;이윤;박홍용
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.427-435
    • /
    • 2010
  • 인장 균열은 콘크리트의 가장 취약한 특성으로 수화열 및 건조수축 등으로 인해 초기재령에서 발생되는 경우가 많다. 초기의 균열을 정확히 예측하기 위해서는 응력-균열 개구 관계가 시간에 따라 어떻게 변화하는 지를 파악해야 한다. 이 연구에서는 기존에 수행되었던 쐐기형 쪼갬 실험결과에 대한 역해석을 수행하였으며, 측정된 하중-균열 개구 변위를 최적으로 모사하는 응력-균열 개구 관계에 대한 쌍선형 연화곡선을 구하였다. 파괴에너지의 시간에 따른 변화에 관한 분석이 이루어졌으며, 분석 결과를 바탕으로 초기재령에서의 응력-균열 개구 관계에 대한 모델을 제안하였다. 최대 하중, 최대 하중에서의 균열 개구 변위, 파괴에너지에 대하여 실험 측정값, 역해석 결과, 모델로부터 계산된 결과들을 비교해 보았으며, 이를 통해 제안된 모델을 검증하였다.

DEVELOPMENT OF 230 GHZ RADIO RECEIVER SYSTEM FOR SRAO

  • Lee, Jung-Won;Kim, Chang-Hee;Kang, Hyunwoo;Lee, Bangwon;Han, Junghwan;Lee, Seok-Ho;Jeong, Il-Gyo;Koo, Bon-Chul;Park, Yong-Sun
    • 천문학회지
    • /
    • 제46권6호
    • /
    • pp.225-234
    • /
    • 2013
  • We develop a radio receiver system operating at ${\lambda}{\sim}1.3$ mm for the 6 m telescope of Seoul Radio Astronomy Observatory. It consists of a dual polarization receiver, a couple of IF processing units, two FFT spectrometers, and associated software. By adopting sideband-separating superconductor mixers with image band terminated to waveguide load at 4.2 K, we achieve $T_{RX}{\leq}100$ K and $T_{sys}$ less than 150 K at best weather condition over 210-250 GHz frequency range. The intermediate frequency signal of 3.5-4.5 GHz is down converted to 0-1 GHz and fed into the FFT spectrometers. The spectrometer covers 1 GHz bandwidth with a spectral resolution of 61 KHz. Test observations are conducted toward several radio sources to evaluate the performance of the system. Aperture and beam efficiencies measured by observing planets are found to be typically 44 ~ 59% and 47 ~ 61%, respectively over the RF band, which are consistent with those measured at 3 mm band previously.

독립형 태양광 발전소의 연 축전지 모니터링장치 개발 (A Monitoring Unit for Lead Storage Batteries in Stand Alone PV Generation Systems)

  • 문채주;김태곤;장영학;김의선;임정민
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.1-7
    • /
    • 2009
  • Use of the PV(photovoltaic) generation system is increased in such areas as remote mountain places or islands at which electrical energy is not serviced. The stand alone PV system is required the power storage products such as battery, fly wheel and super capacitor. Several lead storage batteries are connected in series to get high voltages. The life of lead storage battery is shortened when over charge or over discharge takes place. So, it is needed to control batteries not to be overcharged or be discharged deeply. Voltage of each battery was ignored in former control methods in which overall voltage was used to control charge or discharge battery. In this study, the charging and discharging voltage variations of sealed lead storage batteries with l2V/l.2A were investigated step by step experiments. The results of the test show that one should consider and specify the state of each battery to prevent overcharge or deep discharge. With the basis of the experiments, we designed a monitoring unit to monitor battery voltages simultaneously using micro-controller. The unit measures voltage of 20 batteries simultaneously and displays data on the color LCD monitor with curved line graph. It also sends data to PC using the RS232C communication port. The designed unit was adapted to stand alone PV system with 1kW capacity and lead storage batteries are connected to the PV generation system. The number of lead storage batteries was 10 in series and 12V/250Ah each. Resistive load with 3kW was used for discharging.

A GMDH-based estimation model for axial load capacity of GFRP-RC circular columns

  • Mohammed Berradia;El Hadj Meziane;Ali Raza;Mohamed Hechmi El Ouni;Faisal Shabbir
    • Steel and Composite Structures
    • /
    • 제49권2호
    • /
    • pp.161-180
    • /
    • 2023
  • In the previous research, the axial compressive capacity models for the glass fiber-reinforced polymer (GFRP)-reinforced circular concrete compression elements restrained with GFRP helix were put forward based on small and noisy datasets by considering a limited number of parameters portraying less accuracy. Consequently, it is important to recommend an accurate model based on a refined and large testing dataset that considers various parameters of such components. The core objective and novelty of the current research is to suggest a deep learning model for the axial compressive capacity of GFRP-reinforced circular concrete columns restrained with a GFRP helix utilizing various parameters of a large experimental dataset to give the maximum precision of the estimates. To achieve this aim, a test dataset of 61 GFRP-reinforced circular concrete columns restrained with a GFRP helix has been created from prior studies. An assessment of 15 diverse theoretical models is carried out utilizing different statistical coefficients over the created dataset. A novel model utilizing the group method of data handling (GMDH) has been put forward. The recommended model depicted good effectiveness over the created dataset by assuming the axial involvement of GFRP main bars and the confining effectiveness of transverse GFRP helix and depicted the maximum precision with MAE = 195.67, RMSE = 255.41, and R2 = 0.94 as associated with the previously recommended equations. The GMDH model also depicted good effectiveness for the normal distribution of estimates with only a 2.5% discrepancy from unity. The recommended model can accurately calculate the axial compressive capacity of FRP-reinforced concrete compression elements that can be considered for further analysis and design of such components in the field of structural engineering.