• 제목/요약/키워드: Over and Under Deviation

검색결과 108건 처리시간 0.022초

연료첨가제 주입에 따른 승용차의 규제물질 배출특성 분석 (Characteristic Analysis of Regulated Pollutants Emitted from Passenger Cars according to Fuel Additives)

  • 정성운;손지환;홍희경;성기재;김정수;김정화
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.223-229
    • /
    • 2015
  • This paper was designed to investigate emission characteristics of regulated pollutants (CO, HC, NOx and PM) from 134 diesel and gasoline passenger cars based on emission standards according to fuel additives. The experiments using chassis dynamometer were conducted under NEDC and CVS-75 modes. Comparison for fuel additive management and test between Korea, USA, EU and Japan, Korea was more strict than others. The fuel additives of this study was satisfied within fuel manufacturing standards. For with/without fuel additives according to diesel emission standards, NOx of EURO 4 and EURO 5 showed a relatively similar tendency. In the case of PM reduction rate, EURO 5 was over 20% increased than EURO 4. In the case of standard deviation/average ratio for gasoline vehicles, variation interval was big for LEV 23.3~58% and ULEV 31.6~56.4%. Following the imposition of stricter regulations (EURO 5 and ULEV), difference rate for standard deviation was big. Especially, in the case of diesel vehicles, difference rate for NOx 68% and PM 48% was most big. The results of present study will be of assistance in completing the legislative process and will provide basic data to set up emission standards for fuel additives in Korea.

Forefoot disorders and conservative treatment

  • Park, Chul Hyun;Chang, Min Cheol
    • Journal of Yeungnam Medical Science
    • /
    • 제36권2호
    • /
    • pp.92-98
    • /
    • 2019
  • Forefoot disorders are often seen in clinical practice. Forefoot deformity and pain can deteriorate gait function and decrease quality of life. This review presents common forefoot disorders and conservative treatment using an insole or orthosis. Metatarsalgia is a painful foot condition affecting the metatarsal (MT) region of the foot. A MT pad, MT bar, or forefoot cushion can be used to alleviate MT pain. Hallux valgus is a deformity characterized by medial deviation of the first MT and lateral deviation of the hallux. A toe spreader, valgus splint, and bunion shield are commonly applied to patients with hallux valgus. Hallux limitus and hallux rigidus refer to painful limitations of dorsiflexion of the first metatarsophalangeal joint. A kinetic wedge foot orthosis or rocker sole can help relieve symptoms from hallux limitus or rigidus. Hammer, claw, and mallet toes are sagittal plane deformities of the lesser toes. Toe sleeve or padding can be applied over high-pressure areas in the proximal or distal interphalangeal joints or under the MT heads. An MT off-loading insole can also be used to alleviate symptoms following lesser toe deformities. Morton's neuroma is a benign neuroma of an intermetatarsal plantar nerve that leads to a painful condition affecting the MT area. The MT bar, the plantar pad, or a more cushioned insole would be useful. In addition, patients with any of the above various forefoot disorders should avoid tight-fitting or high-heeled shoes. Applying an insole or orthosis and wearing proper shoes can be beneficial for managing forefoot disorders.

Thermophysical Properties of Acetophenone with Ethylchloroacetate at Temperatures of 303.15, 313.15 and 323.15 K

  • Saravanakumar, K.;Baskaran, R.;Kubendran, T.R.
    • 대한화학회지
    • /
    • 제56권4호
    • /
    • pp.424-430
    • /
    • 2012
  • Densities, viscosities, refractive indices and speed of sounds of the binary mixtures of Acetophenone with Ethylchloroacetate were measured over the entire mole fractions at (303.15, 313.15 and 323.15) K. From these experimental results, excess molar volume $V^E$, viscosity deviation ${\Delta}{\eta}$, refractive index deviation ${\Delta}n_D$, deviations in speed of sound ${\Delta}u$, deviations in isentropic compressibility ${\Delta}k_s$ and excess intermolecular free length ${\Delta}L_f$ were calculated. The viscosity data have been correlated with the equations of Grunberg and Nissan, Hind et al., Tamura and Kurata, Katti and Chaudri, Sedgwick, Krishnan-Laddha and McAllister. The thermo physical properties under study were fit to the Jouyban-Acree model. The excess values were correlated using Redlich-Kister polynomial equation to obtain their coefficients and standard deviations. It was found that in all cases, the data obtained fitted with the values correlated by the corresponding models very well. The results are interpreted in terms of molecular interactions occurring in the solution.

A Study on Pressure Distribution for Uniform Polishing of Sapphire Substrate

  • Park, Chul jin;Jeong, Haedo;Lee, Sangjik;Kim, Doyeon;Kim, Hyoungjae
    • Tribology and Lubricants
    • /
    • 제32권2호
    • /
    • pp.61-66
    • /
    • 2016
  • Total thickness variation (TTV), BOW, and surface roughness are essential characteristics for high quality sapphire substrates. Many researchers have attempted to increase removal rate by controlling the key process parameters like pressure and velocity owing to the high cost of consumables in sapphire chemical mechanical polishing (CMP). In case of the pressure approach, increased pressure owing to higher deviation of pressure over the wafer leads to significant degradation of the TTV. In this study, the authors focused on reducing TTV under the high-pressure conditions. When the production equipment polishes multiple wafers attached on a carrier, higher loads seem to be concentrated around the leading edge of the head; this occurs because of frictional force generated by the combination of table rotation and the height of the gimbal of the polishing head. We believe the skewed pressure distribution during polishing to be the main reason of within-wafer non-uniformity (WIWNU). The insertion of a hub ring between the polishing head and substrate carrier helped reduce the pressure deviation. Adjusting the location of the hub ring enables tuning of the pressure distribution. The results indicated that the position of the hub ring strongly affected the removal profile, which confirmed that the position of the hub ring changes the pressure distribution. Furthermore, we analyzed the deformation of the head via finite element method (FEM) to verify the pressure non-uniformity over the contact area Based on experiment and FEM results, we determined the optimal position of hub ring for achieving uniform polishing of the substrate.

눈의 굴절이상 교정과 사위와의 관계 (A Study of Relationship between Refractive Error Correction and Phoria Amount)

  • 서용원;김대년;강인산
    • 한국안광학회지
    • /
    • 제5권1호
    • /
    • pp.139-146
    • /
    • 2000
  • 눈의 굴정이상을 완전교정한 상태에서 양안시기능 알아보기 위해서 maddox rod를 이용하여 안구 편위량을 측정한 결과, 수평방향의 편위가 없는 정위는 10%, 내사위 55%, 외사위 34%로 나타났으며, 안구의 내측 편위가 외측편위보다 11% 많은 것으로 나타났다. 또한 4 프리즘 이상의 편위량을 갖고 있는 경우도 내사위 23%, 외사위 9%로 나타나 보다 쾌적한 양안시 기능을 유지하기 위해서는 안위이상을 고려한 처방이 되어야 한다. 굴절이상 교정별 안위 이상을 측정한 결과 저교정에서 과교정 상태로 감에 따라 안위의 편위는, 외사위는 감소하고, 내사위는 그 정도가 증가하는 경향을 보였는데 이는 조절의 영향일 것으로 생각된다. 또한, heterophona 법으로 AC/A 비를 측정한 결과, 최저 1.25에서 6.61까지 분포하고 있었으며 굴절이상과는 관련성을 찾아볼 수 없었다.

  • PDF

A Simple Spectrofluorimetric Method for Determination of Mefenamic Acid in Pharmaceutical Preparation and Urine

  • Tabrizi, Ahad Bavili
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권8호
    • /
    • pp.1199-1202
    • /
    • 2006
  • A simple, sensitive and rapid spectrofluorimetric method was developed for determination of mefenamic acid in pharmaceutical preparation and human urine. The procedure is based on the oxidation of mefenamic acid with cerium (IV) to produce cerium (III), and its fluorescence was monitored at 354 nm after excitation at 255 nm. The variables affecting oxidation of drug were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range 0.03-1.5 mg $L^{-1}$. The limit of detection was 0.009 mg $L^{-1}$ and the relative standard deviation for 5 replicate determinations of mefenamic acid at 1.0 mg $L^{-1}$ concentration level was 1.72%. Good recoveries in the range of 102-107 and 102-109% were obtained for pharmaceutical preparation and human urine, respectively. The proposed method was applied to the determination of MF in one pharmaceutical preparation and human urine. The amounts of mefenamic acid found are very similar to those obtained by a standard method.

An Advanced Correlation Algorithm between GTEM and OATS for Radiated Emission Tests

  • Lee, Ae-Kyoung
    • ETRI Journal
    • /
    • 제17권3호
    • /
    • pp.45-63
    • /
    • 1995
  • This paper proposes an algorithm to improve the correlation between giga-hertz transverse electromagnetic (GTEM) cell and open area test site (OATS). It is based on the dipole modeling process of an unknown source object in a GTEM cell and on the evaluation of the approximate far field equations correlated with measured GTEM powers at output port of the GTEM cell. In this algorithm, the relative phase differences between dipole moments play an important part in modeling the test object as a set of dipoles and offer stable calculation of emission values. The radiated emission test using this algorithm requires fifteen orientations of equipment under test, but the increased orientations as compared with the previous method have little effect on the time needed for testing. Radiation from a notebook computer has been tested for statistical analysis of the correlation between GTEM data and OATS data. The emission test results of the notebook computer show that the mean, the standard deviation, and the correlation coefficient are -0.62, 1.99, and +0.85, respectively. These figures indicate that this algorithm provides improved accuracy in the measurement of electromagnetic emissions over the previous method.

  • PDF

탠덤압연설비에서 테이퍼롤 채용에 의한 냉연강판 에지드롭 개선 (Improvement of Edge Drop in Cold Rolled Steel by Tapered Work Roll in Tandem Cold Mill)

  • 한석영;이준정
    • 대한기계학회논문집
    • /
    • 제18권1호
    • /
    • pp.34-43
    • /
    • 1994
  • In order to improve thickness profile of cold rolled steel strip, a computer simulation and actual cold rolling experiments on a 4-high tandem cold mill were carried out. In this study, tapered barrel end at top work roll and incurved barrel body at bottom work roll were examined for reducing edge drop and threading of stripe. Also, the most effective stand of tandem cold mill and magnitude of optimal taper crown at several stand were investigated under a typical rolling condition. From actual rolling experiments, it was verified that thickness deviation over strip width could be improved up to 1.06% by applying tapered and incurved work roll only at the second and up to 0.89% by applying them at both the second and the third stand.

HPLC에 의한 살충제의 동시분리 정량에 관한 연구 -Chlorpyrifos와 Fluvalinate에 대하여- (A study on the Simultaneous Determination of Chlorpyrifos and Fluvalinate by HPLC)

  • 고종명;권문주;이창근;유덕열;허흥덕
    • 환경위생공학
    • /
    • 제7권1호
    • /
    • pp.79-86
    • /
    • 1992
  • Rapid determination of chlorpyrifos and fluvalinate in mixed insecticide was established by using high performance liquid chromatography. Result were as follows : 1. On Lichrosorb${\circledR}$ RP-8(10 ${\mu}m$) Column with on fluent of acetanitrile : water=75 . 25, sufficient separation of Chlorpyrifos and Fluorinate of base was obtained. 2.410td portion the diluted solution was injected in to the cdumn, and the effluent was monitored by on UV-Detector at 270 nm. 3. Relative Standard Deviation were 0.97% (chlorpyrifos) and 0.5% (fluorinate) under analysis conditions. 4. The UV-Detector response at 270 nm were linear (Y=421.8X-2090, $R^2=0.9997$ : Chlorpyrifos, Y= 1062.7X-4017.7, $R^2=0.9998$ : Fluorinate) over a range of 30~500 ${\mu}g/ml$.

  • PDF

간호서비스에 대한 고객만족에 관한 연구;환자의 기대와 성과지각 및 병원 재이용의사 간의 관계 (Customer satisfaction on the nursing services;A relationship among the expectation and the perceived performance and the willingness of reuse of patients on the nursing services)

  • 정원숙;윤숙희
    • 간호행정학회지
    • /
    • 제9권1호
    • /
    • pp.31-40
    • /
    • 2003
  • Purposes : The purpose of this study is to analyze the correlation among Expectations, Performance-Perception, Willingness of reuse of hospital. Methods : The subjects of this study were 120 patients who were admitted in the hospitals over 1 week in Pusan. The data was collected by self-reporting questionnaires from Oct. 16th, to Nov. 5th, 2001. The data were analysed by SPSS/PC package using frequency, percentage, mean, standard deviation, Pearson's correlation coefficient. Results : The results were as follows; 1) The mean score of Expectation was 3 and over. The highest item was 'equal treatment' and the lowest was 'safety in transaction'. 2) The mean score of Performance-Perception was 4 and under. The highest item was 'nurse' attractive appearance' and the lowest was 'equal treatment', 'kindness and etiquette'. 3) The mean score of Willingness of reuse was 3.11. 4) There was a statistical significance of the difference between Expectations and Performance-Perception. The highest difference item was 'equal treatment', and then the lowest difference item was 'working environment arrangement/order'. 5) There were statistically significant positive correlation among Expectations, Performance-Perception, and Willingness of reuse. The highest correlation was 0.89 between Performance-Perception and Willingness of reuse. Conclusions : Nursing managers have to develop nurse training programs for improving of patient's performance perception on nursing service.

  • PDF