• Title/Summary/Keyword: Over Load

Search Result 2,146, Processing Time 0.034 seconds

Calculation of Outdoor Air Fraction through Economizer Control Types during Intermediate Season

  • Hong, Goopyo;Hong, Jun;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose: In this study, we examined outdoor air fraction using historical data of actual Air Handling Unit (AHU) in the existing building during intermediate season and analyzed optimal outdoor air fraction by control types for economizer. Method: Control types for economizer which was used in analysis are No Economizer(NE), Differential Dry-bulb Temperature(DT), Diffrential Enthalpy(DE), Differential Dry-bulb Temperature+Differential Enthalpy(DTDE), and Differential Enthalpy+Differential Dry-bulb Temperature (DEDT). In addition, the system heating and cooling load were analyzed by calculating the outdoor air fraction through existing AHU operating method and control types for economizer. Result: Optimized outdoor air fraction through control types was the lowest in March and distribution over 50% was shown in May. In case of DE control type, outdoor air fraction was the highest of other control types and the value was average 63% in May. System heating load was shown the lowest value in NE, however, system cooling load was shown 1.7 times higher than DT control type and 5 times higher than DE control type. For system heating load, DT and DTDE is similar during intermediate season. However, system cooling load was shown 3 times higher than DE and DEDT. Accordingly, it was found as the method to save cooling energy most efficiently with DE control considering enthalpy of outdoor air and return air in intermediate season.

Experimental studies on the estimation of wind-load of a container crane and its development (풍동시험에 의한 콘테이너 크레인의 풍하중 예측 및 개량에 관한 연구)

  • Kang, S.H.;Lee, D. H.;Cho, K.J.;Choa, S.H.;Huh, J.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.892-899
    • /
    • 1988
  • A container crane model was tested to investigate wind-load characteristics in uniform flows and ground boundary layers. Drag coefficients and moment coefficients show their minimum values at 0, 90, 180 degrees wind directions and maximum values at 60 and 120 degrees. Strong interactions among structure elements produce such variations of the wind-load with wind directions. The BS-2573 code is shown to over-estimation can be reflected in the design stage of cranes by refining the rule of the designer. Some roundings of coners of the engine room and the machinery room reduce the wind-load by 10 percents. Considerable reductions of the wind-load would be expected if further integrated development of the crane structure are executed.

The Dynamic load Balancing Algorithm Method for Heterogeneous Distributed Systems (이종 분산 시스템을 위한 동적 부하균등 알고리즘기법)

  • 장순주
    • Journal of Internet Computing and Services
    • /
    • v.3 no.6
    • /
    • pp.53-61
    • /
    • 2002
  • This paper propose an dynamic load balancing algorithm for heterogeneous distributed systems. The algorithm allows this tasks to be relocated. The key of the algorithm is to transfer a suitable amount of processing demand from senders to receivers. This amount is determined dynamically during sender-receiver negotiations. Factors considered when this amount is determined include processing speeds of different nodes, the current load state of both sender and receiver, and the processing demands of tasks eligible for relocation. This paper also propose a load state measurement scheme which is designed particularly for heterogeneous systems. This results of the study show that the proposed algorithm outperforms the existing algorithms and is stable over a range of system attributes.

  • PDF

Study on the Mechanical Properties of the Rice Plants Subjected to Radial Load -Analysis of Relaxation Behavior- (측방향하중(側方向荷重)에 의한 벼줄기의 역학적특성(力學的特性)에 관한 연구(I) -이완거동 분석-)

  • Huh, Y.K.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.4
    • /
    • pp.402-409
    • /
    • 1993
  • During all mechanical processes rice plants are subjected to verious forces such as natural load of wind and mechanical load of agricultural machines. A force is always accompanied by deformation, which must be either sufficiently great for pressing or sufficiently slight in order to avoid damage. The mechanical behavior of the rice plants is determined by three variables : force, deformation and time. And they must be studied using rheological methods to determine their viscoelastic properties. This study is conducted to experimentally determine the mechanical and rheological properties of the rice stalks subjected to radial load. The force relaxation tests are performed under constant deformation, during which the reduction of forces over time is measured. The mechanical models were developed from the abtained data. The results were as follows : 1. The relaxation behavior of a rice stalk in radial compession may be described by a generalized Maxwell model consisting of 3 Maxwell elements in parallel. 2. Relaxatiom intensity always decreased with increased time of relaxation. 3. The rate of deformation has a significant effect on the relaxation behavior. having increasing pattern with an increase in rate of deformation. 4. The relaxation intensity and residual deformation increased with increased initial load. 5. The relaxtion of the intermediate portion of stalk was bigger tham that of the upper and lower portions.

  • PDF

Estimation of Nonpoint Discharge Coefficient for the Management of Total Maximum Daily Load - Rainfall Discharge Ratio on the Specific Design Flow (수질오염총량관리를 위한 비점배출계수 산정 - 특정 기준유량 시기의 강우배출비)

  • Park, Jundae;Park, Juhyun;Rhew, Doughee;Jeong, Dongil
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.452-457
    • /
    • 2008
  • Nonpoint source (NPS) pollution is caused by rainfall moving over and through the ground. As the runoff moves, it picks up and carries away various pollutants from NPS. The discharge pattern of NPS pollutant loads is affected by the distribution of the rainfall during the year. This study analysed relationship between the rainfall event and the stream flow rate, and estimated the rainfall discharge ratio on the specific design flow which can be used as nonpoint discharge coefficient for the estimation of NPS pollution load. It is considered that nonpoint discharge coefficient can be effectively used for the calculation of NPS pollution load at the time of water quality modelling for the management of Total maximum daily load (TMDL).

Load Balancing for Zone Routing Protocol to Support QoS in Ad Hoc Network

  • Chimmanee, Sanon;Wipusitwarakun, Komwut;Runggeratigul, Suwan
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1685-1688
    • /
    • 2002
  • Application Routing Load Balancing (ARLB) is a novel load balancing mode that combines QoS routing and load balancing in per application to support QoS far real-time application based on wired network. Zone Routing Protocol (ZRP) is a recent hybrid proactive/reactive routing approach in an attempt to achieve scalability of ad-hoc network. This routing approach has the potential to be efficient in the generation of control traffic than traditional routing schemes. Up to now, without proper load balancing tools, the ZRP can actually guarantee QoS for delay-sensitive applications when congestion occurred in ad-hoc network. In this paper, we propose the ARLB to improve QoS fur delay-sensitive applications based on ZRP in ad-hoc network when congestion occurred and to be forwarding mechanism fur route coupling to support QoS for real-time applications. The critical point is that the routing metric of ARLB is originally designed for wired network environment. Therefore, we study and present an appropriate metric or cost computation routing of ARLB for recently proposed ZRP over ad-hoc network environment.

  • PDF

Comparison of Pollutant Control in Combined Sewer Overflows and Separated Sewer Overflows using the Separation Wall (우오수분리벽을 이용한 합류식 하수관거와 분류식 우수관거의 월류수 제어효과 비교)

  • Lim, Bong-Su;Kim, Do-Young;Lee, Kuang-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.458-466
    • /
    • 2007
  • This study is to evaluate control effects of separation wall by surveying water quality and sewer overflows during dry and wet periods in combined sewer and separated sewer systems. Ravine water from the combined Seokgyo outfall with the separation wall was separated about four times larger than sewage flow during dry periods. The water quality of the combined Seokgyo outfall with separation wall during dry periods is flow weighed average BOD 61 mg/L, the combined Cheonseokgyo outfall without the separation wall is average BOD 71 mg/L, and the separated Pyeongsong center outfall is average BOD 41 mg/L. The BOD concentration in separated outfall form about 57% of the combined outfall, and this means the separated outfall (i.e. storm sewer) is polluted by inflow of sewage. The overflow load of the separated outfall is ten times higher than the combined outfall and its overflow load per rainfall is three times than combined outfall during the wet periods. Therefore, the control plan of overflow load is required in storm sewer. The control effects of the overflow load increased 79% by setting the separation wall in the combined sewer, and showed 27% increase without the separation wall in separated sewer, but forecasted over 80% increase of effects if the separation wall was set.

A New Dual-Active Soft-Switching Converter for an MTEM Electromagnetic Transmitter

  • Wang, Xuhong;Zhang, Yiming;Liu, Wei
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1454-1468
    • /
    • 2017
  • In this study, a new dual-active soft-switching converter is proposed to improve conversion efficiency and extend the load range for an MTEM electromagnetic transmitter in geological exploration. Unlike a conventional DC/DC converter, the proposed converter can operate in passive soft-switching, single-active soft-switching, or dual-active soft-switching modes depending on the change in load power. The main switches and lagging auxiliary switches of the converter can attain soft-switching over the entire load range. The conduction and switching losses are greatly reduced compared with those of ordinary converters under the action of the cut-off diodes and auxiliary windings coupled to the main transformer in the auxiliary circuits. The conversion efficiency of the proposed converter is significantly improved, especially under light-load conditions. First, the working principle of the proposed converter is analyzed in detail. Second, the relationship between the different operating modes and the load power is given and the design principle of the auxiliary circuit is presented. Finally, the Saber simulation and experimental results verify the feasibility and validity of the converter and a 50 kW prototype is implemented.

Changes in Mechanical Properties of Wood Due to 1 Year Outdoor Exposure

  • KIM, Gwang-Chul;KIM, Jun-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.12-21
    • /
    • 2020
  • For quantitative evaluation of wooden structures, the mechanical performance of members has undergone outdoor exposure tests. A year-long monitoring was conducted using an SPF species. Test groups were divided into twelve (each month) to measure the moisture content, density and ultimate load. Starting from May when moisture content of the test group was at the lowest, simple failure modes were observed more frequently during the first half of the experiment, whereas complex failure modes took over during the second half. Starting from June when moisture content of the test group was the highest, ultimate load decreased by 30% in the second half compared to the first half. A multiple regression analysis confirmed that moisture content of the test group was the variable with most effect on ultimate load of various outdoor variables, and an estimation equation of a simple regression analysis revealed that moisture content and ultimate load formed an inversely proportionate relationship. It is thought that correlational relationships of variables other than moisture content could be applied with the increase in added data amount by longer periods of outdoor exposure tests.

Characteristics of Short-Circuit Protector in Pad-Mounted Transformer (지상변압기의 단락보호장치 특성연구)

  • Kim, K.H.;Lee, W.Y.;Sun, C.H.;Kim, D.M.;Kim, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1350-1352
    • /
    • 1995
  • This paper discribed the characteristic of I-t cross-over-point between current limited-fuse and explusion fuse(Bay-O-Net Fuse) and fuse protection in pad-mounted transformer that was generated internal faults and the short circuit of secondary side(load side). In the I-t cross-over-point, current limited fuse was melted when transient recovery voltage was raised rapidly.

  • PDF