• Title/Summary/Keyword: Over Load

검색결과 2,146건 처리시간 0.031초

규사광산 지역의 강우시 비점오염원의 유출분석 (Analysis of NPS Pollution Loads over Rainfall-Runoff Events from the Silica Mine Site)

  • 최용훈;원철희;서지연;신민환;양희정;최중대
    • 한국물환경학회지
    • /
    • 제26권3호
    • /
    • pp.413-419
    • /
    • 2010
  • A silica mine monitoring was conducted from March to December in 2008 to measure rainfall, runoff amounts and pollution loads. A total of 13 rainfall-runoff events were measured and analyzed with respect to runoff ratio, pollutant concentration and load, and initial flush. Over rainfall-runoff events, 95% confidence range of SS concentration was 942.5~2,056.2 mg/L. Other measured water quality indices also showed relatively large variation. This wide concentration variation was thought to be caused by the bare working ground of the mine that was used to store, process and transport the mined silica. Total pollution load of the 13 rainfall-runoff events was SS 17,901 kg/ha, $COD_{Cr}$ 160.9 kg/ha, $COD_{Mn}$ 111.24 kg/ha, BOD 79.6 kg/ha, T-N 13.8 kg/ha, T-P 3.5 kg/ha, and TOC 39.3 kg/ha. Initial flush was not well observed except SS. Very high SS concentration and load was occurred when rainfall was large. Therefore, it was recommended to manage the bare ground not to discharge excessive pollutants during wet days by covering the ground or constructing runoff treatment systems such as a sediment basin.

개량형 가동보에 적용하기 위한 패널형 유리섬유보강 폴리머 복합재료 클램핑 플레이트의 환경노출 성능 (Environmental Exposure Performance of a Panel-Type Glass-Fiber-Reinforced Polymer Composite Clamping Plate for an Improved Moveable Weir)

  • 유성열;전종찬;신형진;박찬기
    • 한국농공학회논문집
    • /
    • 제59권5호
    • /
    • pp.73-81
    • /
    • 2017
  • The improved movable weir supplements the advantages and disadvantages of the rubber weir and the conduction gate. It consists of a stainless steel gate, air bags, and a steel clamping plate. The stainless steel gate is the main body of the weir, and the inflatable rubber sheet serves to support the steel gate. The steel clamping plate is typically in direct continuous contact with water, but this leads to corrosion issues that can reduce the life of the entire movable weir. In this study, a panel-type glass-fiber-reinforced polymer (GFRP) clamping plate was designed and fabricated. The test results showed that the flexural load of the panel-type GFRP composite clamping plate was over twice that of the wings type GFRP clamping plate. The lowest moisture absorption value was obtained upon exposure to tap water, and exposure to other solutions showed similar values. Additionally, flexural load testing after exposure to an accelerated environment found the lowest residual loads of 80.51 % and 78.50 % at 50 and 100 days, respectively, for exposure to a $CaCl_2$ solution, while exposure to other environments showed residual failure loads of over 80 % at both 50 and 100 days.

와이어 로프의 파단특성에 관한 실험적 연구 (An Experimental Study on the Fracture Characteristics of Wire Ropes)

  • 김종현;이근오;태순호
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.3-10
    • /
    • 1994
  • This study examines fracture characteristics of wire rope of 6$\times$37+FC 14mm B degree, Which has been widely used for the strength support for machinery, cranes and shipping. The examination Is based on the fellowing experimental conditions. Firstly, this study analyzes the effect of the strength of wlre rope. When number of broken wires is occuring at the level of 5%, 10% and 15% degree respectively in the following two cases:1) Case of broken down to each strand equally. 2) Case of broken down to one strand only. Secondly, this study analyzes the effect of corrosion on the strength of wire rope. Corrosion times are 72hours, 144hours and 216hours corrosion respectively under following conditions. 1) Case of only a corrosion without wire breaking. 2) Case of corrosion after 5% degree wire breaking to each strand equally. Some outcomes of these experiment are as follows. 1) From the of tension test, We can find that the ratio of strength reduction case of wire broke down to one strand concentrically is greater than that ratio case of broke down to each strand equally. 2) From the corrosion test, We can also find that the ratio of strength reduction case of corroded after 5% degree wire breaking to each strand equally Is greater than that ratio case of corroded without wire breaking. 3) After comparing theoretical fracture load of wires with experimental fracture load of wires, we can find the fracture load of the case of broken down to each strand equally is most similar to theoretical fracture load. 4) It is proposed that safety rules on wire rope in the Industrial safety and healthy labor of law have to change “breaking over 10% of number of wires in one strand of wire rope(excluded filler wire )”has to be replaced by“breaking over 10% of number of all wires in all strand of wire rope(excluded filler wire)”

  • PDF

Distributing Network Loads in Tree-based Content Distribution System

  • Han, Seung Chul;Chung, Sungwook;Lee, Kwang-Sik;Park, Hyunmin;Shin, Minho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권1호
    • /
    • pp.22-37
    • /
    • 2013
  • Content distribution to a large number of concurrent clients stresses both server and network. While the server limitation can be circumvented by deploying server clusters, the network limitation is far less easy to cope with, due to the difficulty in measuring and balancing network load. In this paper, we use two useful network load metrics, the worst link stress (WLS) and the degree of interference (DOI), and formulate the problem as partitioning the clients into disjoint subsets subject to the server capacity constraint so that the WLS and the DOI are reduced for each session and also well balanced across the sessions. We present a network load-aware partition algorithm, which is practicable and effective in achieving the design goals. Through experiments on PlanetLab, we show that the proposed scheme has the remarkable advantages over existing schemes in reducing and balancing the network load. We expect the algorithm and performance metrics can be easily applied to various Internet applications, such as media streaming, multicast group member selection.

수질오염총량관리제 대상 오염심화 하천에 대한 오염부하량 할당방법 (Waste Load Allocation Method for Total Maximum Daily Load Program of a Polluted River)

  • 조재현
    • 환경영향평가
    • /
    • 제22권2호
    • /
    • pp.157-170
    • /
    • 2013
  • 수질오염총량관리제 시행 하천에 대해서는 객관적이고 과학적 방법으로 유역내 각 지역의 오염부하량을 할당할 필요가 있다. 본 연구에서는 대도시에서 배출되는 오염부하의 영향을 크게 받는 영산강수계의 중상류부를 대상으로 오염부하량 할당 방법에 대해 검토하였다. 오염부하량 할당을 위한 수질모델링은, 수질관리에 흔히 적용되어온 QUAL2E의 최근 판인, QUAL2Kw를 이용해서 수행하였다. 모델 적용 대상 지역의 각 reach의 수질매개변수는 QUAL2Kw의 자동보정 기능을 이용해서 추정하였다. 오염부하량 할당의 최적화는 유전알고리즘(genetic algorithm)을 이용하였고, 최소부하량 삭감법(least waste load removal allocation), 일정 부하량 이상 최소부하량 삭감법(least waste load removal over a certain value), 동일삭감률 할당법(equal removal rate)의 세가지 방법을 적용하고 비교 검토하였다. 동일삭감률 할당법은 다른 방법보다 유역 전체 부하량 삭감량이 훨씬 크기 때문에 효과적이지 않았고, 이 방법을 쓰기 위해서는 부하량 삭감대상인 각 소유역과 하수처리장을 그 규모와 특성에 따라 세분화할 필요가 있다. 동일삭감률 할당법의 적용시 세가지 범주로 나누어서 삭감률을 적용하였다. 오염부하량 삭감의 효율성을 감안할 때 최소 부하량 삭감법보다 일정 부하량 이상 최소부하량 삭감법이 더 적절한 것으로 검토되었다.

Using XFEM technique to predict the damage of unidirectional CFRP composite notched under tensile load

  • Benzaama, A.;Mokhtari, M.;Benzaama, H.;Gouasmi, S.;Tamine, T.
    • Advances in aircraft and spacecraft science
    • /
    • 제5권1호
    • /
    • pp.129-139
    • /
    • 2018
  • The composite materials are widely used in aircraft structures. Their relative rigidity/weight gives them an important advantage over the metal structures. The objective of this work is to analyze by the finite element method the mechanical behavior of composite plate type notched with various forms under tensile load. Two basic parameters were taken into consideration. The first, the form of the notch in order to see its effect on the stress and the failure load. The second, we studied the influence of the locale orientation of fiber around the plate's notch. These parameters are studied in order to see their effects on the distribution stress and failure load of the plate. The calculation of the failure load is determined numerically with the numerical code ABAQUS using the XFEM (extended Finite Element Modeling) based on the fracture mechanics. The result shows clearly that it is important to optimize the effect of fiber orientation around the notch.

고성능 선형전동기 위치제어 시스템에 대한 최소차원 부하관측기의 실제적 구현 및 이를 이용한 실시간 관성추정기의 구현 (A Study on The Actual Application of the Least Order Load Observer and Effective Online Inertia Identification Algorithm for High Performance Linear Motor Positioning System)

  • 김준석
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.730-738
    • /
    • 2007
  • As well known when the linear machine is operated between two points repeatedly under positioning control, there are various positioning error at the moment of zero speed owing to the non-linear disturbance like as unpredictable friction force. To remove this positioning error, a simple least order disturbance observer is introduced and is actually implemented in this study. Due to this simple algorithm the over-all machine system can be modified to simple arbitrary given one-mass load without any disturbance. So, the total construction process for positioning control system is much easier than old one. Moreover, to generate a proper effective position profile with the limited actual machine force, a very powerful on-line mass identification algorithm using the load force estimator is presented. In the proposed mass identification algorithm, the exact load mass can be calculated during only one moving stage under a normally generated position profile. All presented algorithm is verified with experimental result with commercial linear servo machine system.

Effects of Transverse Reinforcement on Strength and Ductility of High-Strength Concrete Columns

  • Hwang, Sun Kyoung;Lim, Byung Hoon;Kim, Chang Gyo;Yun, Hyun Do;Park, Wan Shin
    • Architectural research
    • /
    • 제7권1호
    • /
    • pp.39-48
    • /
    • 2005
  • Main objective of this research is to evaluate performance of high-strength concrete (HSC) columns for ductility and strength. Eight one-third scale columns with compressive strength of 69 MPa were subjected to a constant axial load corresponding to 30 % of the column axial load capacity and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement (${\rho}_s=1.58$, 2.25 %), tie configuration (Type H, Type C and Type D) and tie yield strength ($f_{yh}=549$ and 779 MPa). Test results show that the flexural strength of every column exceeds the calculated flexural capacity based on the equivalent concrete stress block used in the current design code. Columns with 42 % higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behaviour, showing a displacement ductility factor (${\mu}_{{\Delta}u}$) of 3.69 to 4.85, and a curvature ductility factor (${\mu}_{{\varphi}u}$) of over 10.0. With an axial load of 30 % of the axial load capacity, it is recommended that the yield strength of transverse reinforcement be held equal to or below 549 MPa.

금강에 대한 대장균 부하 지속곡선의 개발 및 적용 (Development and Application of Coliform Load Duration Curve for the Geum River)

  • 김건하;윤재영
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.516-519
    • /
    • 2005
  • An useful protocol coiled load duration curve methodology to estimate contaminant loading to a river on an exceedance probability scale was developed in this research. The technique was further applied to estimate total coliform loading to the Geum River, using the daily mean flow rate and total coliform concentration data during January, 1996 and July, 2004 for the Gongju where an automated monitoring station is located. Drought flow of the Gongju (=50.3 cms) was equivalent to 40% on an exceedance probability scale. Load duration curve for total coliform loading at the Gongju was constructed. Standard duration curve was constructed with the water quality criteria for the class 2 (total coliform concentration = 1000 MPN/100 mL). By plotting load duration curve with standard duration curve, it could be revealed that water quality do not meet the desired water quality for 47% on an exceedance probability scale. If linearity between flow rate and coliform concentration is assumed, it can be interpretated that water quality exceeds desired criteria when average mean flow rate is over 51 cms.

공벽유지용 유체에 따른 대구경 현장타설말뚝의 하중전이특성 (Load Transfer Characteristics on Drilled Shafts by Hole Stability Fluids)

  • 임대성;박성완;박정환;오세훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1100-1105
    • /
    • 2008
  • In most drilled shafts construction sites, it is common, depending on the site condition, to use either water or slurry as fluids for maintaining stability of the holes, however, there are yet no design manuals by hole stability fluids. In this paper, in order to evaluate load transfer characteristics of the drilled shafts by hole stability fluids, two test piles are constructed over the soft ground of the lower Busan Bay based on the Bi-directional Pile Load Test. The test results showed that no ultimate states has found under the condition of applied loads with fresh water and slurry as hole fluids for drilled shafts. Then, the load transfer behavior were estimated with the data measured in fields and the effect of hole stability fluids were compared. All these results are presented in the paper.

  • PDF