• Title/Summary/Keyword: Over Load

Search Result 2,150, Processing Time 0.032 seconds

Evaluating the impacts of using piles and geosynthetics in reducing the settlement of fine-grained soils under static load

  • Shariati, Mahdi;Azar, Sadaf Mahmoudi;Arjomand, Mohammad-Ali;Tehrani, Hesam Salmani;Daei, Mojtaba;Safa, Maryam
    • Geomechanics and Engineering
    • /
    • v.20 no.2
    • /
    • pp.87-101
    • /
    • 2020
  • The construction of combined pile-raft foundations is considered as the main option in designing foundations in high-rise buildings, especially in soils close to the ground surface which do not have sufficient bearing capacity to withstand building loads. This paper deals with the geotechnical report of the Northern Fereshteh area of Tabriz, Iran, and compares the characteristics of the single pile foundation with the two foundations of pile group and geogrid. Besides, we investigate the effects of five principal parameters including pile diameter and length, the number of geogrid layers, the depth of groundwater level, and pore water pressure on vertical consolidation settlement and pore water pressure changes over a year. This study assessed the mechanism of the failure of the soil under the foundation using numerical analysis as well. Numerical analysis was performed using the two-dimensional finite element PLAXIS software. The results of fifty-four models indicate that the diameter of the pile tip, either as a pile group or as a single pile, did not have a significant effect on the reduction of the consolidation settlement in the soil in the Northern Fereshteh Street region. The optimum length for the pile in the Northern Fereshteh area is 12 meters, which is economically feasible. In addition, the construction of four-layered ten-meter-long geogrids at intervals of 1 meter beneath the deep foundation had a significant preventive impact on the consolidation settlement in clayey soils.

Wireless structural health monitoring of bridges: present and future

  • Hoult, Neil A.;Fidler, Paul R.A.;Hill, Peter G.;Middleton, Campbell R.
    • Smart Structures and Systems
    • /
    • v.6 no.3
    • /
    • pp.277-290
    • /
    • 2010
  • Internationally the load carrying capacity of bridges is decreasing due to material deterioration while at the same time increasing live loads mean that they are often exposed to stresses for which they were not designed. However there are limited resources available to ensure that these bridges are fit for purpose, meaning that new approaches to bridge maintenance are required that optimize both their service lives as well as maintenance costs. Wireless sensor networks (WSNs) provide a tool that could support such an optimized maintenance program. In many situations WSNs have advantages over conventional wired monitoring systems in terms of installation time and cost. In order to evaluate the potential of these systems two WSNs were installed starting in July 2007 on the Humber Bridge and on a nearby approach bridge. As part of a corrosion prevention strategy, a relative humidity and temperature monitoring system was installed in the north anchorage chambers of the main suspension bridge where the main cables of the bridge are anchored into the foundation. This system allows the Bridgemaster to check whether the maximum relative humidity threshold, above which corrosion of the steel wires might occur, is not crossed. A second WSN which monitors aspects of deterioration on a reinforced concrete bridge located on the approach to the main suspension bridge was also installed. Though both systems have provided useful data to the owners, there are still challenges that must be overcome in terms of monitoring corrosion of steel, measuring live loading and data management before WSNs can become an effective tool for bridge managers.

Design and Performance Evaluation of Superstructure Modification for Air Drag Reduction of a Container Ship (공기저항 저감을 위한 컨테이너선 상부구조물 형상설계 및 성능평가)

  • Kim, Yoonsik;Kim, Kwang-Soo;Jeong, Seong-Wook;Jeong, Seung-Gyu;Van, Suak-Ho;Kim, Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.1
    • /
    • pp.8-18
    • /
    • 2015
  • Reduction of the fuel oil consumption and corresponding greenhouse gas exhausted from ships is an important issue for today's ship design and shipping. Several concepts and devices on the superstructure of a container ship were suggested and tested in the wind tunnel to estimate the air drag reduction. As a preliminary performance evaluation, air drag contributions of each part of the superstructure and containers were estimated based on RANS simulation respectively. Air drag reduction efficiency of shape modification and add-on devices on the superstructure and containers was also estimated. Gap-protectors between containers and a visor in front of upper deck were found to be most effective for drag reduction. Wind tunnel tests had been carried out to confirm the drag reduction performance between the baseline(without any modification) configuration and two modified superstructure configurations which were designed and chosen based on the computation results. The test results with the modified configurations show considerable aerodynamic drag reduction, especially the gap-protectors between containers show the largest reduction for the wide range of heading angles. RANS computations for three configurations were performed and compared with the wind tunnel tests. Computation result shows the similar drag reduction trend with experiment for small heading angles. However, the computation result becomes less accurate as heading angle is increasing where the massively separated flow is spread over the leeward side.

A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage (하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Chang, Ki-Chang;Ra, Ho-sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF

Thrust Force Characteristics Analysis of Linear Induction Motor Considering Airgap variation for Railway Transit (공극변화를 고려한 철도차량용 선형 유도전동기 특성 연구)

  • Lee, Byung-Song
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1903-1908
    • /
    • 2008
  • This paper presents a characteristics of linear induction motor considering airgap variation for railway transit in order to achieve high performance of the vehicle. The operating principle of a LIM(Linear induction motor) is identical to a rotary induction motor. Space-time variant magnetic fields are generated by the primary part across the airgap and induce the electro-motive force(EMF) in the secondary part, a conducting sheet. This EMF generates the eddy currents, which interact with the airgap flux and so produce the thrust force known as Loren's force. Even though the operating principal is exactly same as a rotary motor, the linear motor has a finite length of the primary or secondary parts and it causes static and dynamic end-effect which is the discontinuous airgap flux phenomenon. This end-effect causes the deterioration of the system performance, especially in high-speed operation. Another problem is that construction tolerance restricts the minimum airgap in order to prevent a collision between the primary part and the secondary reaction plate. More over, as the airgap length is getting smaller, the attraction force between the primary part and secondary parts is getting larger dramatically and the attraction force would be another friction against propulsion. Therefore, it is necessary to figure out the characteristics of linear induction motor considering airgap variation in order to achieve high performance of the vehicle. The dynamic model of LIM taking into account end-effects is derived. Then the modified mechanical load equation considering the effect of the attraction and thrust force according to the airgap variation is analyzed. The simulation results are presented to show the effect of the LIM according to the airgap variation.

  • PDF

Development of TASS Code for Non-LOCA Safety Analysis Licensing Application (Non-LOCA 인허가 해석용 TASS 코드의 개발)

  • Yoon, Han-Young;Auh, Geun-Sun;Kim, Hee-Cheol;Kim, Joon-Sung;Park, Jae-Don
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.53-66
    • /
    • 1995
  • Since the current licensed system codes for Non-LOCA safety analysis are applicable only for a specific type PWR, it is necessary to develope a new system analysis code applicable for all apes of PWRs. As a R&D program, KAERI is developing TASS code as an interactive and faster-than-real-time code for the NSSS transient simulation of both CE and Westinghouse plane. It is flexible tool for PWR analysis which gives the user complete control over the simulation through convenient input and output options. In this paper the code applicability to Westinghouse ape plants was verified by comparing the TASS prediction to plant data of loss of AC power and loss of load transients, and comparing to the prediction of RELAP5/MOD3 for feedline break, locked rotor, steam generator tube rupture and steam line break accidents.

  • PDF

A Study on Exhaust Gas Characteristics and Engine Performance of EGR Valve Installed Engine for Development of EGR Valve Test System (EGR 밸브 평가 장치 개발을 위한 EGR 장착 엔진 성능 및 배출 가스 특성 연구)

  • Na, D.H.;Ko, C.S.;Seo, H.J.;Lee, C.E.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.52-57
    • /
    • 2012
  • In this study, in order to understand contents and ranges of design for the EGR Valve test system for improving quality and performance of EGR Valve, engine performance and exhaust gas characteristic of 3L-class diesel engine was analyzed. Experimental operation of engine performance test was performed with 50% engine load and 20% and 100% opening ratio of EGR Valve. From test of performance and exhaust gas characteristic of engine, torque output of engine and temperature and pressure of inlet and outlet of EGR Valve were measured. As a result, for design of EGR Valve test system, input fluid flow of EGR Valve must be set the same amount with exhaust gas flow that was below of engine speed of 2,500 rpm, and temperature of inlet of EGR Valve must be set under about $510^{\circ}C$. And the difference of temperature between inlet and outlet of EGR Valve must be over than about $200^{\circ}C$. Exhaust gas of inlet and outlet of EGR Valve were under 1 bar that was not considerable, and the difference of pressure between inlet and outlet of EGR Valve were under 1 bar that could not effect on mechanical operation of EGR Valve.

(Development of A Digital Controller of The Electronic Ballast using High Frequency Modulation Method for The Metal Halide Lamp) (메탈 할라이드 램프용 고주파 변조 방식 전자식 안정기의 디지털 제어기 개발)

  • O, Deok-Jin;Kim, Hui-Jun;Jo, Gyu-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.3
    • /
    • pp.228-238
    • /
    • 2002
  • This paper presents a digital controller of the electronic ballast using high frequency modulation method for the metal halide lamp. The proposed controller includes the control algorithm for soft starting, no load protection, over current protection and power control. The proposed digital controller, moreover, has the high frequency modulation scheme and the tracking algorithm to avoid acoustic resonance phenomena. For the math production with the low cost using the ASICs (Application Specific Integrated Circuit), the proposed digital controller has been designed with the FPGAs(Field Programmable Gate array) only, without any microprocessor. In this paper, the detail digital control algorithms are described and the experimental results of prototype 150w metal halide electronic ballast are presented.

The Effect of the Weight of a Backpack on Craniovertebral Angle and Neck Muscle Activities on Some University Students (백팩 무게가 일부 대학생의 머리척추각과 목 근활성도에 미치는 영향)

  • Park, Cheon-jun;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Background: A backpack is available equipment for moving some objects. Most studies have found that the appropriate weight limit of backpack for students is between 10% to 15% of their body weight (BW). However, Some students should carry a backpack heavier than 15% of BW. Therefore, It is associated with abnormal shoulder and neck posture on students. Objects: This study tested the effects that various amounts of weight carried by university students in their backpacks had on their cervical posture and electromyography of neck muscle. Methods: The subjects consisted of 12 students (6 male, 6 female) in university. There were three loading conditions tested: no backpack, a backpack that weighed 10% and 15% of the student's BW. The dependent variables were the craniovertebral angle (tragus to C7) and the neck muscle activities (sternocleidomastoid, upper trapezius). All 12 subjects were asked to walk while wearing a backpack for 5 minutes and were then instructed to rest for 2 minutes. Results: When assessing the craniovertebral angle, the results of this study were significantly decreased in the order of 0%, 10%, and 15%. And then, there were significantly increased electromyography of neck muscles that comparison of the weight of 10% and 15% on 0%. It was found that as the weight of the backpack increased, the craniovertebral angle decreased (p < 0.05) and the muscle activities increased (upper trapezius p = 0.012, sternocleidomastoid p = 0.013). Conclusion: Our study recommended that some students shouldn't carry on over the 15% backpack of own weight, and also they should distribute backpack load to equal on body for optimal posture.

An Exploratory Study of Role Adaptation of Newly Employed Nurses (신규 간호사의 역할적응에 관한 탐색적 연구)

  • 김조자;박지원
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.1
    • /
    • pp.50-60
    • /
    • 1990
  • The purpose of this study was to investigate factors influencing role adaptation in newly employed nurses and the consistency between role expectations before employment and after one year of employment. The results of this study may contribute to strategy development towards positive role adaptation in newly employed nurses. The data used in this study were collected from 111 nurses, the sample was drawn from all newly employed professional nurses working at Y Medical Center in 1987. The data were collected longitudinally in the 2nd - 3rd weeks, the 3rd month and the 12th month after employment. The results of this study were as follows : 1. The degree of change the importance of factors influencing role adaptation and the length of time after employment were investigated. the result showed that the degree of change was the greatest within the first 3 months after employment. Important factors related to role adaptation were working conditions, the environment of the assigned ward and the work load. These factors always displayed high scores without any great change over time. New employees put more importance on practical factors which were obtained through experience in their jobs rather than on ideal factors Which they had considered more important while in school. 2. Consistency between role expectation before employment and after 12 month of employment was investigated. The highest consintency item was the expectation about the variety of Patients, and the highest inconsistency was the expectation about their own welfare. An average score of 69.07 points was achieved from a maximum of 125 points for the 25 items. showing that expectations for role development before employment were not fully satisfied. In conclusion the administraor should assess the initial expectation at the time of employment of new nurses and she / he should make clear to the new nurses that these expectations may not be realistic. In this way the administrator can provide more satisfactory conditions towards the expectations of the new nurses and help them towards positive role adaptation and reduction of role conflict. Newly employed nurses have high and unrealistic expectations about socialization to the profession from their nursing educational program. It is suggested that a transitional training program should be planned and carried out for newly employed nurses.

  • PDF