• 제목/요약/키워드: Outside Insulation

검색결과 133건 처리시간 0.024초

패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구 (A Study of Critical Items and Related Standards on Designing for Passive Apartments)

  • 이명주
    • 대한건축학회논문집:계획계
    • /
    • 제34권7호
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

자켓의 압력 및 두께 변화에 의한 진공 자켓 밸브의 유입 열량 변화에 관한 연구 (A Study on the Heat Flow Change of Vacuum Jacket Valve According to Pressure Change and Jacket Thickness)

  • 김시범;이권희;전락원;도태완
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.232-237
    • /
    • 2011
  • 최근 초저온 밸브 관련 산업의 급속한 발전과 함께 초저온 밸브에 대한 지속적인 연구가 이루어지고 있고 특히, 기계, 조선, 반도체 및 디스플레이 산업, 항공 우주산업분야의 비약적인 발전과 사용자의 요구 등으로 인하여 초저온용 밸브의 고성능화가 되고 있는 추세이나, 진공 단열에 관한 초저온 응용 장비들에 대한 기술개발 및 연구는 미흡한 실정이다. 본 연구에서는 초저온용 진공자켓밸브의 스템 외부에 자켓 배관을 설치 한 후 낮은 압력을 유지함으로써 외부로부터 자켓 내부로의 유입 열전달량을 감소시키는 것에 주안점을 두었고, 효과적인 전열 제어를 위하여 외부로부터 자켓 내부로의 유입 열전달량을 감소시킬수 있는 자켓 내부의 압력과 자켓부의 두께 변화에 관한 열전달 특성을 3차원 수치해석적인 방법으로 연구하여 고찰하였다.

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.

트래킹 검출을 위한 주파수-시간 분석(분할-FFT) (Frequency-Time Analysis(Partition-FFT) for Tracking Detection)

  • 지승욱;이상훈;김충년;이춘하;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권10호
    • /
    • pp.530-538
    • /
    • 2004
  • A electromagnetic waves are used for sensing in insulation diagnosis at electric machine or equipment. When it a method, waves are transformed into the FFT(Fast Fourier Transform); a kind of the process for data transformation. In a general way, a scientist use frequncy band 30[㎒]~l[㎓] to applied field. If we are measured high frequency band, we will need to a high capacity hardware. Also a antenna has a fault on atmospheric phenomena, outside environment and the like. In this paper We proposed new method for detecting electric equipment faulty state using only electric voltage which is generally measured in the electric and electronic field. It is called the Partition-FFT The analytic method is this first divide measured voltage waves into equal parts, second each deal with give effect to the FFT, finally each results deal with a graphic method and gather graphic. We are compare Partition-FFT with discharge form by tracking tester. As the result it demonstrated that the Partition-FFT is applicable.

Development of Ceramic Humidity Sensor for the Korean Next Generation Reactor

  • Lee, Na-Young;Hwang, Il-Soon;Yoo, Han-Ill;Song, Chang-Rock;Park, Sang duk;Yang, Jun-Seog
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.199-206
    • /
    • 1997
  • For the Korean Next Generation Reactor(KNGR) development, LBB is considered for the Main Steam Line(MSL) piping inside its containment to achieve cost and safety Improvement. To apply LBB concept to MSL, leak sensors highly sensitive to humidity is required. In this paper, a ceramic material, MgCr$_2$O$_4$-TiO$_2$ has been developed as a humidity sensor for MSL applications. Experiments peformed to characterize the electrical conductivity shows that the conductivity of MgCr$_2$O$_4$-TiO$_2$ responds sensitively to both temperature and humidity changes. At a constant temperature below 10$0^{\circ}C$, the conductivity increases as the relative humidity increases, which makes the sensor favorable for application to the outside of MSL insulation layer But as temperature increases beyond 10$0^{\circ}C$, the sensor composition should be adjusted for the application to KNGR is to be made at temperature above 10$0^{\circ}C$.

  • PDF

농촌 주거취약계층 주택 개보수 특성에 관한 연구 (A Study on Characteristics of House Repairs for Weak Class in Rural)

  • 정금호
    • 한국농촌건축학회논문집
    • /
    • 제15권4호
    • /
    • pp.17-24
    • /
    • 2013
  • Rural community in Korea being changed to aging community, declining population and income loss by the industrialization and the urbanization. The weak class in rural is confronted with more poorly environment. So it is needed to check the quality of the weak class's house in rural. Basically proposes of this paper is to find ways about rural housing improving and the vitality of rural community. This paper contents rural housing problems through the paper review and house repair characteristics for the weak class. Data for statics analysis were obtained from house repair support program for the weak class in Jeonnam province from 2011 to 2012. The results of this paper are as follow: First, house repair items ranking for the weak class in rural was insulation & heating, toilet, structure, indoor environment, electricity, outside and kitchen & waterproof. This result was reflected that weak class's energy bills is high ratio compared with income. Second, health facilities were improved for the socially disadvantaged's convenience in considering that most of weak class is a senior. Last, most of houses for weak class in rural are old clay wall and block wall. So these houses are reinforced the wall for structural safety.

항공기소음피해지역 설정 기준의 개선방안에 관한 고찰 : 학교를 중심으로 (A Study on the Amendment of Criteria for the Establishment of the Area Damaged by the Aircraft Noise : Criteria for School Classrooms)

  • 이준호;이기호
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.263-269
    • /
    • 2009
  • The purpose of this study is to propose an appropriate criterium for proper sound insulation service preventing school classrooms from aircraft noise. The guideline of noise level for school facility by Korean school health law is less than Leq 55 which is less stringent than that of other countries. It has been reported that many students are annoyed and disturbed for their works when they are exposed to the noise level over Leq 55. It is desirable to modify this guideline of indoor noise level for school classroom. The noise level of classroom of which windows are opened was measured relatively high in case the school is located at the outside of the official area damaged by aircraft noise. In order to minimize the influence of aircraft noise on the school classrooms in the vicinity of domestic airport, it is necessary to improve the present criteria of WECPNL 75 for the establishment of the area damaged by aircraft noise from WECPNL 70.

A Study on the Boiling Heat Transfer Characteristics Using Loop Type Thermosyphon

  • HAN, Kyu-il;CHO, Dong-Hyun
    • 수산해양기술연구
    • /
    • 제52권3호
    • /
    • pp.257-262
    • /
    • 2016
  • Flexible two-phase thermosyphons are devices that can transfer large amounts of heat flux with boiling and condensation of working fluid resulting from small temperature differences. A flexible two-phase thermosyphon consists of a evaporator, an insulation unit, and a condenser. The working fluid inside the evaporator is evaporated by heating the evaporator in the lower part of the flexible two-phase thermosyphon and the evaporated steam rises to the condenser in the upper part to transfer heat in response to the cooling fluid outside the tube. The resultant condensed working fluid flows downward along the inside surface of the tube due to gravity. These processes form a cycle. Using R134a refrigerant as the working fluid of a loop type flexible two-phase thermosyphon heat exchanger, an experiment was conducted to analyse changes in boiling heat transfer performances according to differences in the temperature of the oil for heating of the evaporator, the temperature variations of the refrigerant, and the mass flows. According to the results of the present study, the circulation rate of the refrigerant increased and the pressure in the evaporator also increased proportionally as the temperature of the oil in the evaporator increased. In addition, the heat transfer rate of the boiler increased as the temperature of the oil in the evaporator increased.

발전기 운전에 따른 고정자 권선의 진동 특성 변화 (A Study on the Change of Dynamic Characteristics of Stator Windings due to Generator Operation)

  • 김희수;배용채;이두영;김연환;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1029-1033
    • /
    • 2006
  • During operation of generator, the excitation force with 120Hz always exist irrespective of No. of poles. Therefore the vibration is generated in the stator end windings and the micro-crack is grown up inside the bars. After all, coolant water is leaked outside the bars or the stator is moved and is worn out. What is more, one bar is touched with another bar so a short circuit may frequently happen in operation. In order to prevent it from occurring, the evaluation of mechanical integrity for generator stator windings is carried out periodically during overhaul period. This help troublesome end windings to complement with insulation material and to change vibration characteristics. In this paper, the evaluation of mechanical integrity for generator stator windings is described and the change of vibration characteristics is analysed.

  • PDF

하향식 가스화 장치를 이용한 바이오매스로부터의 합성가스 생산 (Fuel Gas Production from a Down-draft Gasifier using Bionass)

  • 심재훈;홍성구
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.586-591
    • /
    • 2005
  • Syngas or fuel gas production through biomass gasification is a century old technology. Biomass gasification is getting more and more interest recently as one of competitive renewable energy technologies. It does not contribute to increasing greenhouse gases(GHG). A down-draft gasifier was designed and tested for syngas quality using different fuel sets in this study. The gasifier was of about 100kW capacity. Tests were conducted at air flow rates ranging from 10 to $60m^3/hr$. Fuels tested included wood chips and wood char. The results showd that gas quality in terms of flammability was reasonably good when the temperatures were over $600^{\circ}C$ inside the gasifier. Although $800^{\circ}C$ or higher is recommended, gas quality was reasonably good. If insulation was provided outside the gasifier, the temperature would increase. When wood chips were used, the temperature was below $600^{\circ}C$ and gas quality was not good. It seemed that calorific values of fuel and height of reduction zone in the gasifier are very important. The results of the tests would provide important information for designing more improved gasifier and its operation.

  • PDF