• Title/Summary/Keyword: Outrigger Stiffness

Search Result 39, Processing Time 0.026 seconds

Proposal for Optimal Outrigger Location Considering Stiffness of Frame (프레임의 강성을 고려한 최적 아웃리거 위치의 제안)

  • Kim, Hyong-Kee
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.183-190
    • /
    • 2019
  • This paper intended to propose the optimal outrigger position in tall building. For this purpose, a schematic structure design of 70 stories building was accomplished by using MIDAS-Gen. In this analysis research, the key variables were the stiffness of outrigger, the stiffness of frame, the stiffness of shear wall, the stiffness of exterior column connected in outrigger and the outrigger location in height. With the intention of looking for the optimum location of outrigger system in high-rise building, we investigated the lateral displacement in top floor. The study proposed the new method to predict the optimal location of outrigger system considering the frame stiffness. And it is verified that the paper results can be helpful in providing the important engineering materials for finding out the optimum outrigger position in tall building.

Modified Proposal for Optimal Location of Offset Outrigger System in High-rise Building (초고층 오프셋 아웃리거 구조의 최적 위치에 대한 수정제안)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.37-44
    • /
    • 2020
  • This research aimed to propose the more proper equation than the leading and existing equations to predict the optimum location of offset outrigger. In this study, a 79 existing models of offset outrigger system were examined. And the key factors in the existing offset outrigger models were the stiffness of shear wall and offset outrigger system, the stiffness of exterior column connected in offset outrigger, the frame stiffness, the ratios of lateral stiffness of frame in shear wall-frame structures, and all that. This paper proposed the modified equation of predicting the optimal location of offset outrigger system. Additionally, the findings of this study provided the important structure engineering materials of the optimal offset outrigger position in tall building.

Effect of Shear Wall Stiffness on Optimal Location of Core and Offset Outrigger Considering Floor Diaphragm (바닥 격막을 고려한 코어 및 오프셋 아웃리거 구조의 최적위치에 대한 전단벽 강성의 영향)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.37-47
    • /
    • 2019
  • The study purposed to investigate the optimal location of core and offset outrigger system considering floor diaphragm. To accomplish this aim, a structure design of 70 stories building was performed by using MIDAS-Gen. And the leading factors of the analysis research were the slab stiffness, the stiffness of shear wall and the outrigger position in plan. Based on the analysis results, we analyzed and studied the influences of the shear wall stiffness and the slab stiffness on optimal location of core and offset outrigger considering floor diaphragm. The results of the analysis study indicated whether the slab stiffness, the stiffness of shear wall and the outrigger position in plan had an any impact on optimal location in outrigger system of tall building. Also the paper results can give help in getting the structural engineering materials for looking for the optimal position of outrigger system in the high-rise building.

Lateral Behavior in Outrigger System of Tall Building Considering Floor Diaphragm (바닥 격막을 고려한 초고층 아웃리거 구조시스템의 수평거동)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.45-52
    • /
    • 2018
  • The paper aimed to find out the lateral behavior of outrigger system in high-rise building considering floor diaphragm. To achieve this goal, a structural schematic design of 80 stories building was conducted by utilizing MIDAS-Gen. In this research, the key parameters of the structure analysis were the outrigger location in plan, the slab stiffness, the outrigger stiffness and the kind of diaphragm. For the purpose of this study, we analyzed and studied the lateral displacement in top floor, the story drift and the stress in slab. The research results indicated that the outrigger location in plan, the slab stiffness, the outrigger stiffness and the kind of diaphragm had an effect on lateral behavior in outrigger system of tall building. And the results of this analysis research can provided the assistance in getting the basic data of structure design for looking for the lateral behavior of outrigger system in the high-rise building.

Performance Evaluation of Seismic Response Control of Outrigger Damper System with Variation of Damping and Stiffness (아웃리거 댐퍼시스템의 감쇠와 강성 변화에 따른 지진응답제어 성능평가)

  • Lee, Lyeong-Kyeong;Kim, Su-Jin;Lee, Young-Rak;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.3
    • /
    • pp.107-115
    • /
    • 2016
  • In recent years, an outrigger damper system has been proposed to reduce dynamic responses of tall buildings. However, a study on outrigger damper system is still in its early stages. In this study, time history analysis was performed to investigate the dynamic response control performance of outrigger damper. To do this, a actual scale 3-dimensional tall building model with outrigger damper system has been developed. El Centro earthquake was applied as an earthquake excitation. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. Analysis results, on the top floor displacement response to the earthquake load, was greatly effected by damping value. And acceleration response greatly was effected by stiffness value of damper system. Therefore, it is necessary to select that proper stiffness and damping values of the outrigger damper system.

Analysis of Lateral Behavior in Core and Offset Outrigger System (코어 및 오프셋 아웃리거 구조시스템의 수평거동에 대한 분석)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.1-11
    • /
    • 2021
  • The research intended to understand the lateral behavior in core and offset outrigger system. To achieve this goal, a structural analysis and design of 70 stories building was carried out by making use of MIDAS-Gen. And the primary parameters of this analysis were the stiffness of outrigger and the location of outrigger in plan. On the basis of the analysis results, we analyzed the lateral behavior of structural elements such as slab, outrigger and exterior columns in core and offset outrigger. In this analysis research, it is indicated that the stiffness of outrigger and the outrigger location in plan had an any impact on lateral behavior in outrigger system of tall building. Specially, slab stresses in core outrigger system were highly distributed in the slab near the outrigger system to connect shear walls and exterior columns while slab stresses in offset outrigger system were highly distributed in the slab between the outrigger system and shear walls. Also the study results can be of significant help to obtaining the engineering data for the reasonable structure design of the high-rise outrigger system.

Proposal for Optimal Position of Offset Outrigger System (오프셋 아웃리거 구조시스템의 최적 위치에 대한 제안)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.84-91
    • /
    • 2019
  • For the goal of the proposal for optimum position of offset outrigger system, a structural schematic design of 70 stories building was carried out, using the general structure analysis program of MIDAS-Gen. In this research, the primary factors of this analysis research were the shear wall stiffness, the frame stiffness, the outrigger stiffness, the stiffness of column linked in outrigger system, etc. To achieve the aim of this study, we analyzed and studied the lateral displacement in top level, the force distribution of outrigger, the existing model of optimal outrigger location, and so on. This paper proposed the optimal position of offset outrigger system. Furthermore it is considered that the study results can be useful in getting the structure engineering data for seeking the optimal position of offset outrigger in the tall building.

Comparative Analysis on Influence of Structure Elements on Optimal Location of One-Outrigger System (단일 아웃리거 구조시스템의 최적위치에 미치는 구조요소의 영향에 대한 비교분석)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.22-32
    • /
    • 2015
  • This study intended to analyze an influence of the structure elements on the optimal location for one-outrigger system in tall building by using MIDAS-Gen. In this investigation, the analysis parameters were the outrigger position and the stiffness of main structure elements such as shear walls, outrigger systems, exterior columns connected in outrigger system and frames not to be connected in outrigger system. For the objective of finding out the optimal location for one-outrigger system in high-rise building, we studied the lateral displacement in top level of 80 stories building. The results of this study indicated that the outrigger location and the stiffness of main structure elements such as shear walls, outrigger systems, exterior columns connected in outrigger system and frames not to be connected in outrigger system had an influence on the optimal location of one-outrigger system. In addition, it is showed that the research results can be very useful in obtaining the structure design data for looking for the optimal location of one-outrigger system in high-rise building.

Control Performance Evaluation of Outrigger Damper System of Eccentrically Loaded High-Rise Building (편심하중을 가한 고층건물의 아웃리거 댐퍼 시스템 제어성능평가)

  • Kim, Su-Jin;Kim, Su-Geun;Kang, Ho-Geun;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • The demand for skyscrapers is increasing worldwide. Until now, various lateral resistance structures have been used for lateral displacement control of high-rise buildings. An outrigger damper system has been introduced recently to improve lateral dynamic response control performance further. However, a study of outrigger damper system is yet to be sufficiently investigated. In this study, time history analysis was performed to investigate the control performance of an outrigger damper system of high-rise building under eccentric loading. To do this, an actual scale 3-dimensional tall building model with an outrigger damper system was prepared. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. On the top floor torsional angle response to the earthquake load, was greatly affected by damping value. And the displacement response was affected greatly by the stiffness value and damping value of damper system. In conclusion, it is necessary to select the proper damping and stiffness values of the outrigger damper system.

The Evolution of Outrigger System in Tall Buildings

  • Ho, Goman W.M.
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.1
    • /
    • pp.21-30
    • /
    • 2016
  • The structural efficiency of tall buildings heavily depends on the lateral stiffness and resistance capacity. Among those structural systems for tall buildings, outrigger system is one of the most common and efficient systems especially for those with relatively regular floor plan. The use of outriggers in building structures can be traced back from early 50 from the concept of deep beams. With the rise of building height, deep beams become concrete walls or now in a form of at least one story high steel truss type of outriggers. Because of the widened choice in material to be adopted in outriggers, the form and even the objective of using outrigger system is also changing. In the past, outrigger systems is only used to provide additional stiffness to reduce drift and deflection. New applications for outrigger systems now move to provide additional damping to reduce wind load and acceleration, and also could be used as structural fuse to protect the building under a severe earthquake condition. Besides analysis and member design, construction issue of outrigger systems is somehow cannot be separated. Axial shortening effect between core and perimeter structure is unavoidable. This paper presents a state-of-the-art review on the outrigger system in tall buildings including development history and applications of outrigger systems in tall buildings. The concept of outrigger system, optimum topology, and design and construction consideration will also be discussed and presented.