• Title/Summary/Keyword: Output sound pressure

Search Result 59, Processing Time 0.024 seconds

Development of Highly Efficient Underwater Loudspeaker for Attracting and Threatening Fish (어류의 유집과 구집용 수중 스피커 개발에 관한 연구)

  • Kim Chun-Duck;Lee Chai-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Fisheries policy change from catching to farming requires more intensive consideration for aquaculture industry. The oceanic farm is a desirable cost effective aquaculture method. However. in odor to gather fish in the oceanic farm, eating sound or any attracting sound should be radiated through underwater loudspeaker. In this Paper, it has been found in literature that the frequency range responding to fish is about 16Hz to 13kHz but sensitive frequency range is about 150Hz to 2kHz and sound pressure level is about 100dB to 150dB reference $1{\mu}Pa$. Therefore, frequency range and output sound level of designed underwater loudspeaker has been specified as 150Hz to 3kHz and 100dB to 145dB reference $1{\mu}bar$. respectively To verify the stability and the endurance to the pressure of 40m water depth, manufactured underwater loudspeaker was examined before sea trial in manufactured water pressure tank which gives a maximum of 10 atmospheric Pressure. We experimented on acoustic characteristic with manufactured underwater loudspeaker under water depth of 10m.

A Study on Noise Source Identification for Loading Mechanism and Rattle noise about A/V System (차량용 A/V 시스템의 구동부 소음원과 래틀 소음원에 관한 연구)

  • 홍종호;강연준;이상호;이완우;이기석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.189-195
    • /
    • 2003
  • This paper represents an identification procedure for leading mechanism of a car A/V system which is composed of a DC motor and a set of plastic gears. In addition, we studied dominant noise source of rattle noise generated by external forced vibration as a car drives. we made a dynamometer to produce stationary operation on loading mechanism of A/V system because noise generated by actual loading mechanism is non-stationary signal. operating the dynamometer setup at various motor speeds, sound pressure spectra are measured and the results are analyzed. its dominant noise source is also identified by using a sound Intensity technique. we made use of multi-dimensional spectral analysis to rind a dominant rattle noise. this method is so useful to eliminate coherence between vibration sources and helps us obtain coherent output spectrum of individual vibration source which make a rattle noise.

  • PDF

Study of Frequency Response Characteristics in Microphone Used by Optical Sensor

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.128-133
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in microphone using optical sensor, acousto-optic sensor system has been implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point has also been determined by measuring the response characteristics. The choosing the point, which has maximum linearity and sensitivity has changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement /analysis program, "Smaart Live" and "USBPre", which are based on PC, and compared the result from an existing capacitance microphone. The measured optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 4 kHz at up to 3 dB.

Piezoelectric Microspeaker by Using Micromachining Technique (마이크로머시닝 기술을 이용한 압전형 마이크로스피커)

  • Suh, Kyong-Won;Yi, Seung-Hwan;Ryu, Kum-Pyo;Min, Nam-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.45-46
    • /
    • 2005
  • The piezoelectric ZnO thin films were deposited onto Al/Si substrate in order to figure out the crystalline and the residual stress of deposited films. As the $Ar/O_2$ gas ratio is increased, c-axis orientation of deposited films is significantly enhanced and also the residual stresses of ZnO films are all compressive. They are decreased from -1.2 GPa to -950 MPa as the $Ar/O_2$ gas ratio is increased. A diaphragm-based piezoelectric microspeaker fabricated on ONO films shows about 14 mPa output pressure at 1 kHz with $8V_{peak-to-peak}$.

  • PDF

Development of Computer Program for Computation of 12 Refrigerant Properties (12가지 냉매 (R11, R12, R13, R14, R21, R22, R23, R113, R114, R500, R502, C318)의 상태치계산 프로그램)

  • Lee Ki Bang;Chung M. K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.5
    • /
    • pp.477-483
    • /
    • 1987
  • A FORTRAN code has been developed to calculate thermodynamic properties of 12 kinds of refrigerants. Input variables are temperature and pressure or temperature only depending on the saturation. The program output properties are specific volume, saturation pressure, enthalpy, entropy, specific heats and speed of sound. Sample calculations show that output properties are in very good agreements with thermodynamic tables and charts.

  • PDF

Investigation of the Lateral Acoustic Signal Detection Using by Two Fabry-Perot Fiber Optic Sensor Array (두 개의 Fabry-Perot 광섬유 센서 배열을 이용한 횡방향 음압 감지 특성 연구)

  • Lee, Jong kil
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.185-199
    • /
    • 2006
  • In this paper, to detect lateral direction sound pressure fiber optic sensor using Fabry-Perot interferometeric sensor array was fabricated and experimented. This parallel sensor array composed of one light source and the light split into each sensor using directional coupler and to see the output signal the array system do not need any digital signal processor. As a lateral direction sound source arbitrary sound frequency of 100Hz, 200Hz, and 655Hz using by nondirectional speaker were applied to the array sensor which installed on $60cm{\times}60cm{\times}60cm$ latticed structure. The detected signals from the two sensors were analyzed in the time and frequency domains. It was confirmed that the suggested sensor array detected applied sound source well but there were a little amplitude differences in between the sensors. Because the sensor supported simply at both ends theoretical analysis was performed and its solution was suggested. To compare the theoretical and experimental results arbitrary sound frequency of 2kHz was applied to the sensor array. It shows that experimental results was good agreement with theoretical results.

Study on the Measurements of Architectural Acoustie by Cross-Correlation Methods (상호상관법에 의한 건축음향측정에 관한 연구)

  • Park, Byoung-Jeon;Shin, Young-Moo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.42-52
    • /
    • 1990
  • A method of measuring impulse response of acoustic system, two kinds of cross-correlation methods (the direct correlation method and the M-sequence modulation correlation method) were applied. According to the direct correlation method, by using stationary random noise source and by calculating the cross-correlation function between the sourece and the output signal, equivalent impulse response can be obtained not being influenced by the back ground noises. By applying this method, the measurement of echo-time patterns in rooms and oblique incident sound absorption characteristics of sound absorbing materials was carried out. In the case of the M-sequence modulation correlation method which was contrived by Aoshima, an intermittent random nosie modulated by M-sequence signal is used as the source signal, and the cross-correlation function between the M-sequence signal and the squared output signal is calculated. According to this method, equivalent energy impulse response (squared impulse response) of te propagation system can be obtained without being influenced by the back ground noises and the air fluctuation caused by wind. As the applcaition of this measuring method to the architectural acoustics, the meaurements of echo-time patterns, reverberation decays and sound pressure lev디 distributions in rooms and sound insulation efficiencies in buildings were carried out. From these experimental studies, it has been found that this M-sequence modulation correlation method is markedly useful especially for the field masurement of sound insulation under high back ground noise condition.

  • PDF

Characteristics of Piezoelectric Microspeakers according to the Material Properties (물성변화에 따른 압전형 마이크로스피커의 특성)

  • Jeong, Kyong-Shik;Cho, Hee-Chan;Yi, Seung-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.556-561
    • /
    • 2008
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small and constant at low frequency region and shows about 70 dB at 10 kHz. However, in case of a compressively stressed composite diaphragm, the SPL of the fabricated microspeakers shows higher output pressure than those of a tensile-stressed diaphragm. It produces more than 66 dB from 100 Hz to 15 kHz and the highest SPL is about 100 dB at 9.3 kHz with $20V_{peak-to-peak}$, sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone. From the experimental results, it is superior to have a compressively composite diaphragm in order to produce a high SPL in piezoelectric microspeaker.

Characteristics of Piezoelectric Microspeakers according to the Material Properties (물성변화에 따른 압전형 마이크로스피커의 특성)

  • Jeong, Kyong-Shik;Park, Jong-Sun;Cho, Hee-Chan;Yi, Seung-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.37-38
    • /
    • 2007
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small. However, the SPL of the fabricated microspeakers that have compressive-stressed composite diaphragm show higher output pressure than those of tensile-stressed diaphragm. It produces more than 60dB from 100Hz to 15kHz and the highest SPL is about 100dB at 9.3kHz with 20 Vpeak-to-peak sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone.

  • PDF

A Study on Arrangement and Configuration of Acoustic Output Equipment according to Type of Church Broadcast Sources (교회 방송음원의 종류에 따른 음향출력 설비 구성 배치에 관한 연구)

  • Park, Eunjin;Lee, Seonhee
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.80-85
    • /
    • 2016
  • In this paper, by comparatively analyzing horn type speaker and line array type speaker developed based on line sound source theory and point sound source theory, we research whether theory is adaptable or not in real. Academically, point sound source is attenuated as much as 6dB in accordance with double distance and line sound source is attenuated as much as 3dB in accordance with double distance. Line array speaker system developed based on line sound source is analyzed by theory of line sound source about occurring small sound pressure attenuation and it is propose of research that array composition of right speaker is selected in accordance with use purpose and environment. For this purpose, we analyze theory of point sound source and line sound source. we analyze parameter value by simulating designed horn type speaker and line array speaker based on theory.