• 제목/요약/키워드: Output response

검색결과 1,405건 처리시간 0.028초

Mode identifiability of a cable-stayed bridge based on a Bayesian method

  • Zhang, Feng-Liang;Ni, Yi-Qing;Ni, Yan-Chun
    • Smart Structures and Systems
    • /
    • 제17권3호
    • /
    • pp.471-489
    • /
    • 2016
  • Modal identification based on ambient vibration data has attracted extensive attention in the past few decades. Since the excitation for ambient vibration tests is mainly from the environmental effects such as wind and traffic loading and no artificial excitation is applied, the signal to noise (s/n) ratio of the data acquired plays an important role in mode identifiability. Under ambient vibration conditions, certain modes may not be identifiable due to a low s/n ratio. This paper presents a study on the mode identifiability of an instrumented cable-stayed bridge with the use of acceleration response data measured by a long-term structural health monitoring system. A recently developed fast Bayesian FFT method is utilized to perform output-only modal identification. In addition to identifying the most probable values (MPVs) of modal parameters, the associated posterior uncertainties can be obtained by this method. Likewise, the power spectral density of modal force can be identified, and thus it is possible to obtain the modal s/n ratio. This provides an efficient way to investigate the mode identifiability. Three groups of data are utilized in this study: the first one is 10 data sets including six collected under normal wind conditions and four collected during typhoons; the second one is three data sets with wind speeds of about 7.5 m/s; and the third one is some blind data. The first two groups of data are used to perform ambient modal identification and help to estimate a critical value of the s/n ratio above which the deficient mode is identifiable, while the third group of data is used to perform verification. A couple of fundamental modes are identified, including the ones in the vertical and transverse directions respectively and coupled in both directions. The uncertainty and s/n ratio of the deficient mode are investigated and discussed. A critical value of the modal s/n ratio is suggested to evaluate the mode identifiability of the deficient mode. The work presented in this paper could provide a base for the vibration-based condition assessment in future.

건설관리에서의 PROMETHEE기반 공정 리스크 분석 (Analysis of the Schedule Risk using PROMETHEE in Building Construction Management)

  • 이장영;윤유상;장명훈;서상욱
    • 한국건설관리학회논문집
    • /
    • 제11권2호
    • /
    • pp.25-34
    • /
    • 2010
  • 최근 건설 프로젝트는 규모의 대형화, 공정의 복잡함 등에 의한 리스크 인자의 발생이 증가하고 있다. 이로 인해 건설관리에서 리스크 관리의 중요성은 더욱 부각되고 있는 현실이다. 리스크 관리는 확인, 분석, 대응의 과정을 통해서 이루어지며, 분석과정에서 위험인자들의 중요도 및 우선순위를 객관적이고 정확하게 분석해내는 것이 리스크 관리의 성공여부를 좌우한다. 본 연구는 기존연구에서 건설 프로젝트의 공정 리스크 중요도 및 우선순위를 산출하는데 사용된 AHP 기법의 문제점을 보완하기 위하여 PROMETHEE를 활용한 정량적 분석 프로세스를 제시하였다. PROMETHEE를 사용함으로써 AHP 기법에서 분석대상 인자가 9개를 초과 할 때의 신뢰성 저하와 인자의 추가 또는 삭제 시 발생하는 복잡한 산출절차의 문제점을 보완할 수 있을 것으로 기대된다.

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

Analysis of the Influence of Electrical Discharge Machining Parameters on Surface Roughness of CK45

  • Abedi, Esmail;Daneshmand, Saeed;Karimi, Iman;Neyestanak, A. A. Lotfi
    • Journal of Electrochemical Science and Technology
    • /
    • 제6권4호
    • /
    • pp.131-138
    • /
    • 2015
  • Electrical discharge machining is an unconventional machining process in which successive sparks applied to machine the electrically conductive materials. Any changes in electrical discharge machining parameters lead to the pieces with distinct surface roughness. The electrical discharge machining process is well applied for high hardness materials or when it is difficult to use traditional techniques to do material removing. Furthermore, this method is widely applied in industries such as aerospace, automobile, molding, and tool making. CK45 is one of the important steels in industrial and electrical discharge machining can be considered as a proper way for its machining because of high hardness of CK45 after thermal operation of the electrical discharge machining process. Optimization of surface roughness as an output parameters as well as electrical discharge machining parameters including current, voltage and frequency for electrical discharge machining of CK45 has been studied using copper tools and kerosene as the dielectric. For such a purpose and to achieve the precise statistical analysis of the experiment results design of experiment was applied while non linear regression method was chosen to assess the response of surface roughness. Then, the results were analyzed by means of ANOVA method and machining parameters with more effects on the desired outputs were determined. Finally, mathematical model obtained for surface roughness.

펄스형 고전압 측정용 용량성 분압기 (Capacitive Voltage Divide for a Pulsed High-Voltage Measurement)

  • 장성덕;손윤규;권세진;오종석;조무현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.63-68
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source are under operation for 2.5 GeV electron linear accelerator in Pohang Light Source (PLS) linac. The klystron-modulator system has an important role for the stable operation to improve an availability statistics of overall system performance of klystron-modulator system. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are demanded for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider (CVD), which divides input voltage as capacitance ratio, is intended for the measurement of a beam voltage of 400 kV generated from the klystron-modulator system. Main parameter to determine standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will be present and discuss the design concept and analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance effects and oil temperature variation.

하수방류수 재이용을 위한 Birm filter + UF 적용시 용도별 사용 가능성 및 막오염 특성 (Possible Uses of Reclaimed Wastewater Effluent Treated Using Birm Filtration Along UF, and Analysis on Membrane Fouling)

  • 정진희;이승철;성낙창;최영익
    • 한국환경과학회지
    • /
    • 제25권11호
    • /
    • pp.1467-1474
    • /
    • 2016
  • In response to the water shortage problem, continued attempts are being made to secure consistent and reliable water sources. Among various solutions to this problem, wastewater effluent is an easy way to secure the necessary supply, since its annual output is consistent. Furthermore, wastewater effluent has the advantage of being able to serve various purposes, such as cleaning, sprinkling, landscaping, river management, irrigation, and industrial applications. Therefore, this study presents the possible use of reclaimed industrial wastewater treated with Birm filters and a UF membrane, along with an analysis on membrane fouling. The preprocessing stage, part of the reclamation process, used Birm filters to minimize membrane fouling. Since this study did not consider heavy metal levels in the treated water, the analyses did not include the criterion for irrigation water quality. However, the wastewater reclaimed by using Birm filters and a UF membrane met every other requirement for reclaimed water quality standards. This indicated that the treated water could be used for cleaning, channel flow for maintenance, recreational purposes, and industrial applications. The analysis on the fouling of the Birm filter and UF membrane required the study of the composition and recovery rate of the membrane. According to SEM and EDX analyses of the UF membrane, carbon and oxygen ion composition amounted to approximately 57%, whereas inorganic matter was not detected. Furthermore, the difference in the recovery rates of the distressed membrane between acidic and alkaline cleaning was more than ~78%, which indicated that organic rather than inorganic matter contributed to membrane fouling.

m-section의 위상반전이 있는 Mach-Zehnder형 진행파 $Ti:LiNbO_3$ 광변조기 (Mach-Zehnder Type $Ti:LiNbO_3$ Traveling-Wave Optical Modulator with m-Section Phase Reversal)

  • 이우진;김경암;김우경;김창민
    • 대한전자공학회논문지SD
    • /
    • 제39권7호
    • /
    • pp.26-36
    • /
    • 2002
  • z-cut $LiNbO_3$ 기판위에 3-section, 5-section 위상반전 전극을 가진 Mach-Zehnder형 진행파 광변조기를 설계 및 제작하였다. FDM(Finite Difference Method : 유한 차분법)을 이용하여 광도파로를 설계하였으며, MW(Microwave)전극 taper영역의 입${\cdot}$출력단에서는 CMM(Conformal Mapping Method: 등각사상법)을, 변조영역에서는 SOR(Successive Over Relaxation: 반복 이완법)을 이용하여 설계를 수행하였다. 제작된 소자의 S 파라미터를 측정하였다. 측정된 S파라미터를 이용하여 이론적으로 주파수응답 R(${\omega}$)을 구하였다. 3-section 전극의 경우 중심 주파수 25GHz에 ${\sim}$15GHz의 대역폭, 5-section의 경우 중심 주파수 45GHz에 ${\sim}$22GHz의 대역폭을 갖는 bandpass 동작을 나타낼 것으로 예측되었다.

Improvement of the Cognitive Perceptual Assessment for Driving (CPAD) based on Usability Test

  • Bae, Jae-Hyuk;Lee, Jung-Ah;Choi, Hyun;Lee, Jae-Jin
    • 대한인간공학회지
    • /
    • 제34권4호
    • /
    • pp.335-351
    • /
    • 2015
  • Objective: The aim of this study was to perform a usability test for CPAD (Cognitive Perceptual Assessment for Driving) and improve it based on the test results. Background: The cognitive perceptual assessment for driving is a computer-based assessment tool to assess the driving capacity of people with brain-damages. It may be a good tool for evaluating the brain-damaged drivers' safe driving capabilities and screening cognitive and perceptual deficits related to driving. We performed a usability test to improve the CPAD based on the result. Method: Both the software consisting of 8 sub-tests (depth perception, sustained attention, divided attention, stroop test, field dependency, digit span, trail making A, trail making B) and the hardware including the input and output devices ( joystick, mouse, keyboard, touch screen) were evaluated through user interviews. Also we identified the problems and issues in using them by observing the participants performing the CPAD tasks. Results: Based on the results, the task instructions were visually and auditorily improved and more practice examples were added to help the users understand the instructions better and increase the input accuracy, a response time window was added and the joystick and touch screen were simplified, which made it easier for the user to perform the CAPD tasks. Conclusion: User discomforts were minimized by improving the task environment, unless it had affected the evaluation criteria. Application: We plan to distribute the improved version of the CPAD to the regional rehabilitation hospitals, and the driving support centers for people with disabilities throughout the country, so it could be used as an evaluation tool for disabled drivers' cognitive and perceptual functions.

비접촉식 진동 변위센서의 특성에 관한 연구 (Study on characteristics of noncontact vibrating displacement sensor)

  • 조철환;조성태;양경현
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2011
  • This thesis is about the result of conducting a specific experiment for the development of noncontact vibration displacement sensor for measuring the spindle vibration that is used for conditional monitoring of machinery. One should be careful when using the eddy current type displacement sensor because the sensitivity of it is different according to the quality of the material. While the probe used for nondestructive inspection adopts the effect of transmitting the material by using the high frequency domain, the eddy current type displacement sensor uses the lower frequency of around 1MHz. Also, while the nondestructive probe uses the method of enhancing output by using the resonance zone, the vibration displacement sensor utilizes the stable zone by avoiding the resonance zone. Since the oscillator of the converter uses the "L" element as Probe, its characteristic changes with the variation of a relevant impedance. In other words, if the length of Probe's Cable gets extended (Impedance increase), the sensitivity declines accordingly. The effect of surrounding temperature was small, but the influence of the quality of Sensor Coil used was high. Moreover, following an experimental demonstration of the phenomenon where the sensitivity decreases as the frequency of the tested material increases from a frequency response test, the maximum frequency that could be measured was approximately 1KHz. It was noted that the degree of precision could be maintained by using the gap of the probe in the linear zone at the installation site.

ERP 기반의 비즈니스 프로세스 재설계 방법 (A Business Process Redesign Method within an ERP Framework)

  • Dong-Gill Jung
    • 한국전자거래학회지
    • /
    • 제7권1호
    • /
    • pp.87-106
    • /
    • 2002
  • The behavioral and dynamic implications of an ERP implementation/installation are, to say the least, not well understood. Getting the switches set to enable the ERP software to go live is becoming straightforward. The really difficult part is understanding all of the dynamic interactions that accrue as a consequence. Dynamic causal and connectionist models are employed to facilitate an understanding of the dynamics and to enable control of the information-enhanced processes to take place. The connectionist model ran be analyzing (behind the scenes) the information accesses and transfers and coming If some conclusions about strong linkages that are getting established and what the behavioral implications of those new linkages and information accesses we. Ultimately, the connectionist model will come to an understanding of the dynamic, behavioral implications of the larger ERP implementation/installation per se. The underlying connectionist model will determine information transfers and workflow. Once a map of these two infrastructures is determined by the model, it becomes a relatively easy job for an analyst to suggest improvements in both. Connectionist models start with analog object structures and then use learning to produce mechanisms for managerial problem diagnoses. These mechanisms are neural models with multiple-layer structures that support continuous input/output. Based on earlier work performed and published by the author[10][11], a Connectionist ReasOning and LEarning System(CROLES) is developed that mimics the real-world reasoning infrastructure. Coupled with an explanation subsystem, this system can provide explanations as to why a particular reasoning structure behaved the way it did. Such a system operates in the backgmund, observing what is happening as every information access, every information response coming from each and every intelligent node (whether natural or artificial) operating within the ERP infrastructure is recorded and encoded. The CROLES is also able to transfer all workflows and map these onto the decision-making nodes of the organization.

  • PDF