• Title/Summary/Keyword: Output Measurement

Search Result 1,465, Processing Time 0.025 seconds

An Empirical Comparative Study on the Clustering Measurement Using Fuzzy(Average Index Transformation) DEA and Cross-efficiency Models (퍼지(평균지수변환)DEA모형과 교차효율성모형을 이용한 클러스터링측정에 대한 실증적 비교연구)

  • Park, Ro-Kyung
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.1
    • /
    • pp.85-110
    • /
    • 2015
  • The purpose of this paper is to show the clustering trend and the empirical comparison and to choose the clustering ports for 3 Korean ports(Busan, Incheon and Gwangyang Ports) by using the Fuzzy(Average Index Transformation) DEA and Cross-efficiency models for 38 Asian ports during 11 years(2001-2011) with 4 input variables(birth length, depth, total area, and number of crane) and 1 output variable(container TEU). The main empirical results of this paper are as follows. First, clustering results by using Fuzzy(AIT)DEA show that 3 Korean ports[Busan(56.29%), Incheon(57.96%), and Gwangyang(66.80%) each]can increase the efficiency. Second, according to Cross-efficiency model, Busan(Hongkong, Kobe, Manila, Singapore, and Kaosiung etc.), Incheon(Aquaba, Dammam, Karachi, Mohammad Byin Oasim and Davao), and Gwangyang(Damman, Yokohama, Nogoya, Keelong, Kaosiung, and Bangkok) should be clustered with those ports in parentheses. Third, when both Fuzzy(AIT)DEA and Cross-efficiency models are mixed, the empirical result shows that 3 Korean ports[Busan(71.38%), Incheon(103.89%), and Gwangyang(168.55%) each]can increase the efficiency. The efficiency ranking comparison among the three models by using Wilcoxon Signed-rank Test was matched with the average level of 66%-67%. The policy implication of this paper is that Korean port policy planner should introduce the Fuzzy(AIT)DEA, and Cross-efficiency models with the mixed two models when clustering is needed among the Asian ports for enhancing the efficiency of inputs and outputs. Also, the results of SWOT analysis among the clustering ports should be considered.

Calculation and measurement of optical coupling coefficient for bi-directional tancceiver module (양방향 송수신모듈 제작을 위한 광결합계수의 계산 및 측정)

  • Kim, J. D.;Choi, J. S.;Lee, S. H.;Cho, H. S.;Kim, J. S.;Kang, S. G.;Lee, H. T.;Hwang, N.;Joo, G. C.;Song, M. K.
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.500-506
    • /
    • 1999
  • We designed and fabricated a bidirectional optical transceiver module for low cost access network. An integrated chip forming a pin-PD on an 1.3 urn FP-LD was assembled by flip-chip bonding on a Si optical bench, a single mode fiber with an angled end facet was aligned passively with the integrated chip on V-groove of Si-optical bench. Gaussian beam theory was applied to evaluate the coupling coefficients as a function of some parameters such as alignment distance, angle of fiber end facet, vertical alignment error. The theory is also used to search the bottle-neck between transmittance and receiving coupling efficiency in the bi-directional optical system. Tn this paper, we confirmed that reduction of coupling efficiency by the vertical alignment error between laser beam and fiber core axis can be compensated by controlling the fiber facet angle. In the fabrication of sub-module, a'||'&'||' we made such that the fiber facet have a corn shape with an angled facet only core part, the reflection of transmitted laser beam from the fiber facet could be minimized below -35 dE in alignment distance of 2: 30 /J.m. In the same condition, transmitted output power of -12.1 dEm and responsivity of 0.2. AIW were obtained.

  • PDF

Discussion about the Self Disposal Guideline of Medical Radioactive Waste (의료용 방사성폐기물 자체처분 가이드라인에 관한 고찰)

  • Lee, Kyung-Jae;Sul, Jin-Hyung;Lee, In-Won;Park, Young-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.13-27
    • /
    • 2017
  • Purpose In the procedure of domestic medical radioactive self-disposal, there are many requests of supplementation and difficulties on the screening process. In this regard, presentation of basic guideline will improve the work processing efficiency of medical institution radioactive waste. From 2015 to 2016, We reviewed and compared a supplementary requests of domestic fifteen medical institution radioactive self-disposal Plan & Procedure manual. In connection with this, we derive the details of the radioactive waste document based on the relative regulation of nuclear safety Act. The representative supplementary requests of Korea Institute of Nuclear Safety are disposal method of non-flammability radioactive waste, storage method of scheduled self-disposal waste, the legitimacy of self-disposal and pre-treatment of self-disposal, reference radioactivity of disused filter and output of storage period, attachment the evidential matter of measurement efficiency when using a gamma counter. Through establishing a medical radioactive waste guideline, we can clearly suggest a classification standard of radioactive nuclide and the type of occurrence. As a result, we can confirm the reduction of examination processing period while preparing a self-disposal document and there is no spending expenses for business agency. Also, the storage efficiency of facility will better and reduce the economic expenses. On the basis of this guideline, we will expect a contribution to the improvement of work efficiency for officials who has a working-level difficulty of radioactive waste self-disposal.

  • PDF

Measurement of the Photon Fluence for the Evaluation of Photon Detection Efficiency of Photon Counting Sensor (광계수형 센서의 포톤계수효율 평가를 위한 포톤플루엔스 측정)

  • Park, Ji-Koon;Heo, Ye-Ji;Kim, Kyo-Tae;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Recently, the various digital X-ray imaging devices using CCD and TFT LCD-based flat panel digital X-ray sensor are being used. In particular, a number of studies on photon counting sensor technique have been reported. In this study, the incident X-rays fluence on the photon counting sensor material was measured to estimate photon detection efficiency which is the quantitative performance evaluation factor of photon counting sensor. The result of measuring the photon fluence by using RQA-M2 Radiation beam quality of IEC 61223-1-2 recommendations, the incident photon fluence could be defined as about $4 photons/(0.01mm)^2{\cdot}{\mu}Gy$ within $10{\mu}m$ pin-hole area, and about $50photons/(0.03mm)^2{\cdot}{\mu}Gy$ within $30{\mu}m$ pin-hole area, and about $698photons/(0.1mm)^2{\cdot}{\mu}Gy$ within $100{\mu}m$ pin-hole area. Consequently, with the previously setup of the incident fluence, the measuring of actual photon counting efficiency by observing the output waveform of the photon counting sensor material was considered possible.

Radio Frequency Circuit Module BGA(Ball Grid Array) (Radio Frequency 회로 모듈 BGA(Ball Grid Array) 패키지)

  • Kim, Dong-Young;Jung, Tae-Ho;Choi, Soon-Shin;Jee, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.8-18
    • /
    • 2000
  • We presented a BGA(Ball Grid Array) package for RF circuit modules and extracted its electrical parameters. As the frequency of RF system devices increases, the effect of its electrical parasitics in the wireless communication system requires new structure of RF circuit modules because of its needs to be considered of electrical performance for minimization and module mobility. RF circuit modules with BGA packages can provide some advantages such as minimization, shorter circuit routing, and noise improvement by reducing electrical noise affected to analog and digital mixed circuits, etc. We constructed a BGA package of ITS(Intelligent Transportation System) RF module and measured electrical parameters with a TDR(Time Domain Reflectometry) equipment and compared its electrical parasitic parameters with PCB RF circuits. With a BGA substrate of 3${\times}$3 input and output terminals, we have found that self capacitance of BGA solder ball is 68.6fF, and self inductance 146pH, whose values were reduced to 34% and 47% of the value of QFP package structure. S11 parameter measurement with a HP4396B Network Analyzer showed the resonance frequency of 1.55GHz and the loss of 0.26dB. Routing length of the substrate was reduced to 39.8mm. Thus, we may improve electrical performance when we use BGA package structures in the design of RF circuit modules.

  • PDF

Evaluation of Clinical Usefulness of EIS(Electro Interstitial Scan) (EIS(Electro Interstitial Scan) 방법의 임상적 유효성 연구)

  • Kim, Soochan;Bae, Jang-Han;Jun, Min-Ho;Kim, Jaeuk U.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.124-133
    • /
    • 2015
  • Electro interstitial scan shows potential as a non-invasive screening method. It can discriminate some diseases based on electric current response to induce low intensity direct current to limbs or local area of body. DDFAO was invented in France and it is claimed that multi-channel EIS(Electro Interstitial Scan) is useful for various diseases, especially, diagnoses of endocrine system such as diabetics are very effective. In this study, we verified the repeatability and sensitivity of DDFAO by using a RC phantom model and its clinical usefulness using data obtained from normal and diabetes subject groups. As a result, it showed the repeatability and the output change according to change of phantom characteristic, but it was hard to distinguish normal and patient groups non-invasively with just six surface electrodes of DDFAO. The repeatability and the clinical accuracy was not sufficient for screening or diagnostic purposes, as well. In spite of the results with low repeatability and accuracy conducted in this study, we still need further investigations to improve the EIS-based measurement method; EIS is very convenient and simple and it shows potential as a screening tool of the whole body health conditions rather than localized disease diagnosis.

Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC (이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계)

  • Shin, Young-San;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.68-73
    • /
    • 2013
  • In this paper, we proposed a readout circuit of pulse waveform and rate for a U-health system to monitor health condition. For long-time operation without replacing or charging a battery, either pulse waveform or pulse rate is selected as the output data of the proposed readout circuit according to health condition of a user. The proposed readout circuit consists of a simple digital logic discriminator and a dual-mode ADC which operates in the ADC mode or in the count mode. Firstly, the readout circuit counts pulse rate for 4 seconds in the count mode using the dual-mode ADC. Health condition is examined after the counted pulse rate is accumulated for 1 minute in the discriminator. If the pulse rate is out of the preset normal range, the dual-mode ADC operates in the ADC mode where pulse waveform is converted into 10-bit digital data with the sampling frequency of 1 kHz. These data are stored in a buffer and transmitted by 620 kbps to an external monitor through a RF transmitter. The data transmission period of the RF transmitter depends on the operation mode. It is generally 1 minute in the normal situation or 1 ms in the emergency situation. The proposed readout circuit was designed with $0.11{\mu}m$ process technology. The chip area is $460{\times}800{\mu}m^2$. According to measurement, the power consumption is $161.8{\mu}W$ in the count mode and $507.3{\mu}W$ in the ADC mode with the operating voltage of 1 V.

A Compact 20 W Block Up-Converter for C-Band Satellite Communication (C-대역 위성 통신용 20 W급 주파수 상향 변환기의 소형화)

  • Jang, Byung-Jun;Moon, Jun-Ho;Jang, Jin-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.352-361
    • /
    • 2010
  • In this paper, a compact 20 W block-up-converter for C-band satellite communication is designed and implemented. The designed block up-converter consists of an intermediate frequency circuit, a mixer and local oscillator, a driver amplifier, a solid-state power amplifier, waveguide circuits, and a power supply module. To reduce the size of the block-up-converter, all circuits are assembled within an housing, so its dimension is just $21{\times}14{\times}11cm^3$. Especially, the waveguide filter and microstirp-to-waveguide transition are easily implemented using an housing. Also, to meet spurious and harmonics specification, various compact microstrip filters including an elliptic filter are integrated. Measurement results show that the developed block up-converter has good electrical performances: the output power of 43.7 dBm, the minimum gain of 65 dB, the gain flatness of ${\pm}1.84$, the IMD3 of -35 dBc, and the harmonic level of -105 dBc.

S-Band 300-W GaN HEMT Harmonic-Tuned Internally-Matched Power Amplifier (S-대역 300 W급 GaN HEMT 고조파 튜닝 내부 정합 전력증폭기)

  • Kang, Hyun-Seok;Lee, Ik-Joon;Bae, Kyung-Tae;Kim, Seil;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.290-298
    • /
    • 2018
  • Herein, an S-band internally-matched power amplifier that shows a power capability of 300 W in a Long Term Evolution(LTE) band 7 is designed and fabricated using a CGHV40320D GaN HEMT from Wolfspeed. Based on the nonlinear model, the optimum source and load impedance are extracted from the source-pull and load-pull simulations at the fundamental and harmonic frequencies, and the harmonic impedance tuning circuits are implemented inside a ceramic package. The internally matched power amplifier, which is fabricated using a thin-film substrate with a high relative permittivity of 40 and an RF35TC PCB substrate, is measured at the pulsed condition with a pulse period of 1 ms and a duty cycle of 10%. The measured results show a maximum output power of 257~323 W, a drain efficiency of 64~71%, and a power gain of 11.5~14.0 dB at 2.62~2.69 GHz. The LTE-based measurement shows a drain efficiency of 42~49% and an ACLR of less than -30 dBc(excluding 2.62 GHz) at an average power of 79 W.

Study for Multi Channel Radiation Detector Using of Microfilm and Carbon Electrode (탄소막 마이크로필름을 이용한 다채널 전리함 개발에 관한 연구)

  • Shin Kyo Chul;Yun Hyong Geun;Jeong Dong Hyeok;Oh Yong Kee;Kim Jhin Kee;Kim Ki Hwan;Kim Jeung Kee
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.111-115
    • /
    • 2005
  • We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5$\%$, linearity was less than 0.5$\%$, and dose rate effect was less than 0.7$\%$. In addition the effect of dose variation from other chambers was estimated to maximum 0.8$\%$ approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.

  • PDF