• Title/Summary/Keyword: Outlet water temperature

Search Result 224, Processing Time 0.03 seconds

A Study to Calculate Inlet Fluid Temperature of the Borehole Heat Exchanger (BHE) using Modified TOUGHREACT (Modified TOUGHREACT를 이용한 지중 열교환기 내 순환 유체의 온도 분포 추정)

  • Kim, Seong-Kyun;Bae, Gwang-Ok;Lee, Kang-Kun;Shim, Byoung-Ohan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.477-480
    • /
    • 2007
  • Inlet fluid temperature of the BRE in the geothermal heat pump system depends on heat exchange rate between the refrigerant of the heat pump and the leaving fluid from the BRE. Because the outlet fluid temperature of the BHE varies with time, inlet fluid temperature has to vary with time. In this study, the module to calculate inlet fluid temperature is developed, which can consider the time-varying outlet fluid temperature and the heat exchange capacity of the heat pump. It is assumed that heat loss or gain of the leaving fluid from outlet to inlet of the BHE is negligible, except when the fluid contacts with the refrigerant of the heat pump. This module is combined with TOUGHREACT, a widely accepted three-dimensional numerical simulator for heat and water flow and geochemical reactions in geothermal systems and is applied to data analyses of the thermal response test.

  • PDF

Climatological Analysis of Fog Occurrence at Chuncheon (춘천지방에서 발생한 안개 특성 분석)

  • Baek, Seung-Joo;Lee, Kwi-Ok;Leem, Heon-Ho;Lee, Hwa-Woon
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.583-591
    • /
    • 2007
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years (2000-2003) data at Chuncheon. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for 2-4 hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1 m/s. Especially, about 42 % of foggy day fell on the calm($0{\sim}0.2m/s$) conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water sur-face temperature was calculated by using Water Quality River Reservoir System (WQRRS). In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

Development of Waterproof Electric Outlet using Silicon Packing Technology (실리콘 패킹 기술을 이용한 방수 콘센트의 개발)

  • Choi, Chung-Seog;Kim, Chang-Soung
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.85-87
    • /
    • 2008
  • In this paper, we manufactured waterproof outlet that use silicon packing know-how. Developed outlet is waterproof packing on pins of the plug insertion hole and electric wire insertion hole. Therefore, outlet body internal furnace water can prevent that is flowed in. Temperature anomaly can use in back large outer wall, restaurant exposed easily to moisture, bathroom, laundry, a laboratory and science room, auditorium, etc. That is estimate that contribute on courtesy call of electricity calamity.

  • PDF

Studies on Performance of CO2 Water Heater by Numerical Modeling (수치적 모델링을 통한 이산화탄소 급탕기의 특성 연구)

  • Park, Han Vit;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • Numerical modeling of $CO_2$ water heater was conducted prior to optimal design of medium and large sized $CO_2$ water heater, and the experimental test with small sized $CO_2$ water heater having heat capacity of 4 kW was completed to verify the present numerical model. The present model estimated the experimental data of COP(coefficient of performance), heating capacity, and the hot water outlet temperature within the range of 3% to 8% of mean deviation. As increase of EEV(electric expansion valve) opening area, decreasing of heating capacity and the hot water outlet temperature, and increasing of COP were found in both experimental and numerical investigation.

A Study on the Performance Improvement of Pressure Compensating Temperature Control Valve (압력 평형식 온도조절 밸브 성능 향상을 위한 연구)

  • Kim T.-A.;Kim Youn J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.671-674
    • /
    • 2002
  • Pressure compensating temperature control valve(TCV) is one of the important control devices, which is used to maintain the constant temperature of working fluid in power and chemical plants. The ratio of cylinder hole diameters of inlet and outlet is the main design parameters of TCV. So this needs to be investigated to improve the function of control of temperature and void fraction. In this study, numerical analysis is carried out with various ratios of cylinder hole diameters of the inlet and outlet in the TCV. Especial1y, the distribution of the static pressure Is investigated to calculate the new coefficient($C_{\upsilon}$) and resistance coefficient(K). The governing equations are derived from making using of three-dimensional Naver-Stokes equations with standard $k-{\varepsilon}$ turbulence model and SIMPLE algorithm. Using a commercial code, PHOENICS, pressure and flow fields in TCV are calculated with different inlet and outlet diameters of the cylinder hole for cold and hot water passages.

  • PDF

An Experimental Study on Variable-Speed Control of an Ground-Water Circulation Pump for a Ground Source Multi-Heat Pump System (주거용 건물 지열원 멀티 히트펌프시스템의 지열순환펌프 가변유량제어에 관한 실증연구)

  • Song, Suwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.443-449
    • /
    • 2013
  • The purpose of this study is to propose an enhanced variable-speed control method of ground-water circulation pumps using inlet and outlet ground-water temperature difference and analyze its effect for the ground source multi-heat pump system installed in a single-family house. As a result, it has shown to significantly reduce the electricity use of ground-water circulation pump and improve overall system Coefficient of Performance (COP) due to the proposed variable-speed control under partial load conditions after oversized and inefficient single-speed pump retrofit.

An Experimental Study on Transition and Film Boiling Heat Transfer of Impinging Water Jet (충돌수분류의 천이 및 막비등열전달에 관한 연구)

  • Ohm, Ki-Chan;Seo, Jeong-Yun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.2
    • /
    • pp.87-97
    • /
    • 1985
  • Experimental measurements of the heat flux to a upward impinging water jet on high heated test surface were obtained in the transition and film boiling regimes. Test variables were nozzle outlet velocity, subcooled water temperature and height of supplementary water. Boiling curve of this investigation is similar to a pool boiling curve, but it has one or two cap-shaped peaks in the transition regime. In the film boiling regime, the heat transfer rates are increased along with the increment of nozzle outlet velocity and subcooled temperature. There is optimum height of supplementary water for the augmentation of heat transfer Generalized correlations of boiling heat transfer are presented for maximum heat flux, minimum heat flux and $q_c$ at each supplementary height.

  • PDF

Analysis of Meteorological Features and Prediction Probability Associated with the Fog Occurrence at Chuncheon (춘천의 안개발생과 관련된 기상특성분석 및 수치모의)

  • Lee Hwa Woon;Lee Kwi Ok;Baek Seung-Joo;Kim Dong Hyeok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.303-313
    • /
    • 2005
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years $(2000\~2003)$ data at Chuncheon and the probability of prediction is investigated. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for $2\~4$ hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1m/s. Especially, about $42\%$ of foggy day fell on the calm $(0\~0.2\;ms^{-1})$ conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water surface temperature was calculated by using Water Quality River Reservoir System (WQRRS) and then it was used as the surface boundary condition of MM5. The numerical experiment was carried out for 2 days from 1300 LST on 14 October 2003 to 1300 LST on 16 October 2003 and fog was simulated at dawn on 15 and 16 October 2003. Simulated air temperature and dew point temperature indicate the similar tendency to observation and the simulated difference between air temperature and dew point temperature has also the similar tendency within $2^{\circ}C$. Thus, the occurrence of fog is well simulated in the terms of the difference between air temperature and dew point temperature. Horizontal distribution of the difference between air temperature and dew point temperature from the numerical experiment indicates occurrence, dissipation and lasting time of fog at Chuncheon. In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

Configuration and Analysis of a Feed-forward Control System for Jacket Cooling Water Temperature of Marine Prime Diesel Engine (주기관 쟈케트냉각수 온도를 위한 피드포워드 제어시스템의 구성과 분석)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1303-1308
    • /
    • 2008
  • Keeping cooling water temperature higher within the allowable range helps marine engines to run in more efficient condition especially when the engine load is low. Temperature control of jacket cooling water in outlet side of main engine has been more widely adopted to ships these days for the purpose to reduce fuel consumption rate. But If the temperature sensor for the control loop is placed at the outlet of engine, it brings more difficulties in attaining stable and desirable properties due to dead times included in pipe length and engine itself comparing to the case where the measuring point is at the inlet side of main engine. In relation with this problem, Feed-forward control could be one of realistic solutions as it reveals good properties and requires less cost for system configuration. This study suggests a forward control system which leads to improved temperature control performances to disturbance signals which could arise from variation of engine load or weather condition. Two dead times in the modelling were described, considering pipe length between the actuator and the engine as well as the thermal process inside the engine. The results of analysis were shown by simulations to confirm responses under different conditions.

Monitoring of Outlet Discharge and Water Quality from a Small Agricultural Reservoir (소규모 농업용 저수지의 통관 방류량 및 수질 측정)

  • Choi, Jin-Kyu;Son, Jae-Gwon;Koo, Ja-Woong;Yoon, Kwang-Sik;Kim, Young-Ju
    • Journal of Korean Society of Rural Planning
    • /
    • v.6 no.2 s.12
    • /
    • pp.73-81
    • /
    • 2000
  • This study was carried out to measure the amount of outlet discharge and analyse the water quality from an agricultural reservoir. Joongpyong reservoir was selected as the monitoring site. Daily discharge was determined by measured water level data of delivery canal and the stage-discharge relation curve. The measured water discharge through culvert outlet of Joongpyong reservoir was 593,200m3 which was equivalent to irrigation depth 1,186mm during irrigation period in 1999. And water samples were taken from the surface water of reservoir and delivery canal, periodically. Temporal variation of water quality constituents such as water temperature, pH, EC, total nitrogen, total phosphorus were investigated. The result showed that pH was ranged 6.9 7.8, total nitrogen 1.39 4.11mg/L, total phosphorus 0.007 0.036 mg/L, respectively.

  • PDF