• Title/Summary/Keyword: Outer wall facilities

Search Result 19, Processing Time 0.024 seconds

A Basic Study on the Development of Filling Material using Seismic Retrofit of Masonry Architectural Wall Systems in Educational Facilities. (교육시설물의 조적치장벽체 내진보강에 적용 가능한 충전재 개발 기초연구)

  • Lee, Joo-Hyeong;Oh, Jun-Seok;Jeon, Sang-Sub;Son, Ki-Young;Na, Young-Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.180-181
    • /
    • 2019
  • South Korea has long been without major earthquakes. But 317 public facilities have been damaged by Po-Hang earthquake. Among them, 103 educational facilities suffered 25.6 billion won worth of damage. This is the most damaging of public facilities. The earthquake damage was mainly centered on non-seismic retrofit educational facilities and masonry architectural wall systems installed on the outer walls of buildings. Therefore, the purpose of this study is to develop a filling material that can be applied to the non-seismic retrofit of masonry architectural wall systems installed on the outer walls of educational facilities. To achieve the objective, first, set the filling material requirements. Second, set the sequence model of experiments and prepare for the experiment. Third, after the experiment, analyze the results obtained through the experiment. Forth, the optimal filling material is selected by comparing the analyzed results with the requirements. As a results, E-S-X sample using epoxy resin were selected for the seismic retrofit of masonry architectural wall systems in educational facilities. In the future, this study can be used as a basic material for developing seismic reinforcement methods guidelines in domestic existing educational facilities.

  • PDF

A Study of Environment-friendly outer wall facilities for the improvement of port pollution (항내오염 개선을 위한 친환경 외곽시설에 관한 연구)

  • 김강민;강석형;유하상;김상훈
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.165-170
    • /
    • 2003
  • Due to the impermeability of outer wall facilities such a Breakwaters which dissipates the wave energy and keeps harbor tranquility, the water exchange can be worse and increased enclosed at the harbor. Recent trends of port development protect water quality and emphasize Water-Front, so the method which enhances the circulation of harbor waters and the dilution of the water pollutants are studied. The best improvement of water quality is a remove of pollutant source on land, but an enclosed port must be enhanced the tidal exchange. To this hence, the best improvement may be made on drain-route on the existing outer wall facilities. In this study, the numerical computations were carried out to predict the circulation of harbor waters and the tidal exchange in the polluted harbor(Samchonpo-guhang) located at the east coast of South Sea. Computational models adopting FDM(Finite Difference Method) were used here and were already verified from the previous studies and ocean survey. As a result of this study, the tidal exchange in Samchonpo-guhang before and after installation of drain-route is assessed.

  • PDF

Frequency-Domain Analysis for Motion of Floating Structures with Perforated Wall (유공벽이 설치된 부유체 동요 평가를 위한 주파수 영역 해석)

  • Jeongsoo Kim;Youn Ju Jeong;Young-Taek Kim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • As increasing demands for a floating structure expanded from offshore industry facilities to living facilities, it has emerged that necessity of techniques to reduce motions of a floating structure. This study present a floating structure with porosity on the outer surface of the floater. Under each regular and irregular wave, responses of the floater was investigated in frequency domain. The proposed structure is composed of inner and outer floaters, which are connected to each other and the outer wall is perforated, and the heave and the pitch of floaters with different perforation rates (0~30%) were compared with at both the center and the edge. The results showed that pitch responses can be decreased by increasing of perforation rate of the floater. Comparing with responses of the non-perforated floater, those of the proposed floating structure were reduced to above 10% and 2%, respectively for regular and irregular wave conditions.

Design of a Mobile Robot System for Integrity Evaluation of Large Sized Industrial Facilities (대형 산업설비 안전성 진단용 이동로봇 시스템 설계)

  • Lee Ho-Gil;Ryuh Young-Sun;Son Woong-Hee;Jeong Hee-Don;Park Sangdeok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.7
    • /
    • pp.595-601
    • /
    • 2005
  • A mobile robot system utilizing NDT (Non-Destructive Testing) method is designed and fabricated f3r automatic integrity evaluation of large sized industrial reservoirs and pipelines. The developed mobile robot can crawl over the outer surface of the industrial facilities even though the shape of the structures is various and unsymmetric. The robot detects defects such as pinholes, cracks and thickness reduction at the wall of the facilities using EMAT (Electro-Magnetic Acoustic Transducer). Image processing technology for weld line detection at the surface of the target and host programs including defect detecting algorithms are also developed. Automation of defect detection for these kinds of large facilities using mobile robots is helpful to prevent significant troubles of the structures without danger of human beings under harmful environment.

An Open Space of College Campus according to the Changes of the Times : A Visual Analysis of Cases (대학(大學) 캠퍼스 광장(廣場)의 시대적(時代的) 변천(變遷) : 시각적(視覺的) 사례(事例) 분석(分析))

  • Min, Chang-Kee
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.9 no.2
    • /
    • pp.25-35
    • /
    • 2002
  • This paper is to evaluate an open space on university campuses enclosed within buildings, with respect to building elevation a wall of an open space including outer wall materials and window forms and an open space itself. It uses case study methods to periodically know specific details about open spaces and surrounding buildings elevation. It was found, at first, that it was emphasized vertical elements on window frames as well as building elements in an era of the 1910's to the 1930's. It, however, was changed into emphasizing on horizontal features in the era of the 1960's to the 1970's. Meanwhile the period from the 1940's to the 1950's was a turning point. The horizontal style was continued until the 1980s and the style was changed into various style mixed with various types. Secondly, an open space was recognized as a valuable design criteria for a construction of buildings in the 1930s to the 1970s. It was, however, a forgotten criteria during the late 1970's and the 1980's because of short age of the construction budget of the government. In the 1990's, the importance of open space design reappeared on the design of a block plan. Thirdly, a design style of an open space was authoritarianism using symmetrical and magnificent style in the 1910's to the 1930's. The time of 1945 to the 1950's was a turning point from authoritarianism to an idea of efficiency. In the 1960's and the 1970s, an idea of efficiency emphasizing their functions was prevalent to the design of buildings and open spaces and this trend was continued until the 1980's. A romanticism was realized on the design of an open space and surrounded building's.

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 균열저감 대책 연구)

  • Kim, Eun-Kyum;Youn, Seok-Goo;Bae, Sang-Il;Jeong, Jae-Yong;Kim, Hyeon-Cheol;Heo, Jeong-Ok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.425-428
    • /
    • 2006
  • The bigger of concrete strctures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box strucuture, the use of blended cement, the temperature of air and concrete, control joint, was considered and analysed by a three dimensional finite element method.

  • PDF

A Counterplan of temperature crack control by a heat of hydration of Subway concrete box structure concerned External Temperature (대기온도를 고려한 지하철 콘크리트 Box 구조물의 수화열에 의한 온도균열제어 대책)

  • Roh, Hyun-Sup;Kim, Eun-Kyum;Yang, Sin-Chu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.581-584
    • /
    • 2007
  • The subway concrete box structure can`t establish expansion joint because of animal power delivery of the subway rail. In this case, As increase of structure volume, it is subjected to cause temperature crack. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, examined a condition of temperature crack occurrence by a heat of hydration concerned external temperature from analysing by a three dimensional finite element method.

  • PDF

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (콘크리트 BOX 구조물의 수화열에 의한 온도균열제어 대책)

  • Kim, Eun-Kyum;Jeon, Chan-Ki;Jeon, Joong-Kyu;Bae, Sang-Il
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.705-708
    • /
    • 2006
  • The bigger of concrete structures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, which is located in chloride attack region, the use of blended cement, the temperature of air and concrete, was considered and analysed by a three dimensional finite element method.

  • PDF

A Study on Environmentally Friend Counter Facilities for Improvement of Harbor Water Quality (항내수질 개선을 위한 친환경 외곽시설에 관한 연구)

  • Kim, Kang-Min;Kang, Suk-Hyong;Ryu, Ha-Sang;Kim, Sang-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.2
    • /
    • pp.233-238
    • /
    • 2003
  • Due to the impermeability of outer wall facilities such as Breakwaters which dissipates the wave energy and keeps harbor tranquility, the enclosed area of harbor becomes partially blocked and the water exchange can be reduced. Recent trends of port development protect water quality and emphasize Water-Front, so the method which enhances the circulation of harbor waters and the dilution of the water pollutants are studied. The best improvement of water quality is a remove of pollutant source on land, but an enclosed port must be enhanced the tidal exchange. For this end, the best improvement may be made a drain-route on the existing outer wall facilities. In this study, the numerical computations were carried out to predict the circulation of harbor waters and the tidal exchange through the drain-rout in the polluted harbor(Samchonpo-guhang) located at the east coast of South Sea. Computational models adopting FDM(Finite Difference Method) were used here and were already verified from the previous studies und ocean survey. As a result of this study, circulation and the tidal exchange at the harbor before and after introduction of drain-route were assessed.

An Analysis of the Place Branding Methods for Regenerated Idle Industrial Facilities (재생 유휴산업시설의 플레이스 브랜딩 방법 분석)

  • Cho, Youn-Joo;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.54-63
    • /
    • 2015
  • This study aims to suggest the place branding methods applicable for regenerated idle industrial facilities. The place branding methods were analyzed by separating into hard branding methods and soft branding methods, and the results of the study are as follows: As for the hard branding methods, the exterior, outer wall materials and interior materials of the building and industrial equipment are preserved to revive the historicity of the building. In order to organize a differentiated space, it is important to create the convenience space such as cafes, experience space, lounge, and restaurants as well as the space for the operation of the programs. The building itself is utilized as a landmark or the iconic facility such as the winding tower or chimney is utilized as a landmark. As the methods of introducing natural elements, there is a need to create the resting space, law area and water space where trees can be planted and landscape can be viewed, and the development of tourism products utilizing the peripheral resources and the link of programs are also important. As for the soft branding methods, the provision of programs where a variety of art genres and the sense of place are reflected and the programs linked to the region is needed, and the story of place can be shared by storytelling utilizing the work and programs reflecting the sense of place. In addition, the content development and physical improvement of facilities reflecting the needs of visitors and the establishment of the organic collaboration system of a variety of subjects are needed for the sustainability of place.