• 제목/요약/키워드: Outer wall facilities

검색결과 19건 처리시간 0.024초

교육시설물의 조적치장벽체 내진보강에 적용 가능한 충전재 개발 기초연구 (A Basic Study on the Development of Filling Material using Seismic Retrofit of Masonry Architectural Wall Systems in Educational Facilities.)

  • 이주형;오준석;전상섭;손기영;나영주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.180-181
    • /
    • 2019
  • South Korea has long been without major earthquakes. But 317 public facilities have been damaged by Po-Hang earthquake. Among them, 103 educational facilities suffered 25.6 billion won worth of damage. This is the most damaging of public facilities. The earthquake damage was mainly centered on non-seismic retrofit educational facilities and masonry architectural wall systems installed on the outer walls of buildings. Therefore, the purpose of this study is to develop a filling material that can be applied to the non-seismic retrofit of masonry architectural wall systems installed on the outer walls of educational facilities. To achieve the objective, first, set the filling material requirements. Second, set the sequence model of experiments and prepare for the experiment. Third, after the experiment, analyze the results obtained through the experiment. Forth, the optimal filling material is selected by comparing the analyzed results with the requirements. As a results, E-S-X sample using epoxy resin were selected for the seismic retrofit of masonry architectural wall systems in educational facilities. In the future, this study can be used as a basic material for developing seismic reinforcement methods guidelines in domestic existing educational facilities.

  • PDF

항내오염 개선을 위한 친환경 외곽시설에 관한 연구 (A Study of Environment-friendly outer wall facilities for the improvement of port pollution)

  • 김강민;강석형;유하상;김상훈
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2003년도 춘계공동학술대회논문집
    • /
    • pp.165-170
    • /
    • 2003
  • 파랑에너지를 차단하고 항내 정온을 확보하기 위해 설치된 외곽시설인 방파제는 불투과성이기 때문에 항만을 폐쇄성으로 만들 수 있으며, 외간의 해수교환은 급격히 감소될 수 있다. 항만개발의 최근 추세는 항내의 수질 보호와 친수성이 강조되어, 기존의 불투과성 방파제의 일부에 투과성으로 설계한 제체투과성 해수교환방파제를 설치하여 외해의 에너지가 항내로 전달되어 항내 오염물질의 희석률 증대와 함께 외해로 배출되도록 하고 있다. 오염이 심화된 항만에서 항내 수질을 개선하기 위한 방안은 육상오염원을 제거하는 것이 최선이나, 폐쇄성이 큰 항만의 경우, 외해와의 해수순환을 강화시켜야만 한다. 즉, 기존의 항만에서의 항내 수질개선을 위해서 외곽시설의 일부에 해수소통구를 두는 방법이 가장 최선이라 할 수 있다. 본 연구에서는 항내 오염이 심각한 항만을 대상으로 하여, 해수소통구를 통한 해수순환 양상을 검토하고 수반되는 해수교환을 검토하고자 한다. 이를 위해 해수유동 및 오염확산 수치모델을 구축하고 대안에 따른 항내의 해수순환 및 해수교환을 평가하였다.

  • PDF

유공벽이 설치된 부유체 동요 평가를 위한 주파수 영역 해석 (Frequency-Domain Analysis for Motion of Floating Structures with Perforated Wall)

  • 김정수;정연주;김영택
    • 한국해안·해양공학회논문집
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2024
  • 해상 산업시설을 중심의 부유식 구조물 수요가 생활 밀접형 시설로 점차 확대됨에 따라, 부유 구조물의 동요를 저감하기 위한 기술 필요성이 대두되고 있다. 본 연구는 부유체 외부에 유공벽이 설치된 부유식 구조물을 제시하고, 규칙파 및 불규칙파 조건에서의 주파수 영역 해석을 통해 해당 구조물의 응답을 조사하였다. 제안된 구조물은 내부 부유체와 유공벽이 포함된 외부 부유체가 결합된 형태로, 유공률별(0~30%) 해석 모델을 생성해 부유체 중심점과 가장자리에서의 상하 및 회전 동요가 비교되었다. 해석 결과는 유공벽의 유공률 증가를 통해 부유체의 상하 및 회전 동요를 저감할 수 있음을 보여주었다. 또한 제안된 부유체를 사용함으로써 무유공 부유체 대비 규칙파와 불규칙파 조건에서 각각 10%, 2% 내외의 응답 감소 효과가 나타남을 확인할 수 있었다.

대형 산업설비 안전성 진단용 이동로봇 시스템 설계 (Design of a Mobile Robot System for Integrity Evaluation of Large Sized Industrial Facilities)

  • 이호길;류영선;손웅희;정희돈;박상덕
    • 제어로봇시스템학회논문지
    • /
    • 제11권7호
    • /
    • pp.595-601
    • /
    • 2005
  • A mobile robot system utilizing NDT (Non-Destructive Testing) method is designed and fabricated f3r automatic integrity evaluation of large sized industrial reservoirs and pipelines. The developed mobile robot can crawl over the outer surface of the industrial facilities even though the shape of the structures is various and unsymmetric. The robot detects defects such as pinholes, cracks and thickness reduction at the wall of the facilities using EMAT (Electro-Magnetic Acoustic Transducer). Image processing technology for weld line detection at the surface of the target and host programs including defect detecting algorithms are also developed. Automation of defect detection for these kinds of large facilities using mobile robots is helpful to prevent significant troubles of the structures without danger of human beings under harmful environment.

대학(大學) 캠퍼스 광장(廣場)의 시대적(時代的) 변천(變遷) : 시각적(視覺的) 사례(事例) 분석(分析) (An Open Space of College Campus according to the Changes of the Times : A Visual Analysis of Cases)

  • 민창기
    • 교육시설
    • /
    • 제9권2호
    • /
    • pp.25-35
    • /
    • 2002
  • This paper is to evaluate an open space on university campuses enclosed within buildings, with respect to building elevation a wall of an open space including outer wall materials and window forms and an open space itself. It uses case study methods to periodically know specific details about open spaces and surrounding buildings elevation. It was found, at first, that it was emphasized vertical elements on window frames as well as building elements in an era of the 1910's to the 1930's. It, however, was changed into emphasizing on horizontal features in the era of the 1960's to the 1970's. Meanwhile the period from the 1940's to the 1950's was a turning point. The horizontal style was continued until the 1980s and the style was changed into various style mixed with various types. Secondly, an open space was recognized as a valuable design criteria for a construction of buildings in the 1930s to the 1970s. It was, however, a forgotten criteria during the late 1970's and the 1980's because of short age of the construction budget of the government. In the 1990's, the importance of open space design reappeared on the design of a block plan. Thirdly, a design style of an open space was authoritarianism using symmetrical and magnificent style in the 1910's to the 1930's. The time of 1945 to the 1950's was a turning point from authoritarianism to an idea of efficiency. In the 1960's and the 1970s, an idea of efficiency emphasizing their functions was prevalent to the design of buildings and open spaces and this trend was continued until the 1980's. A romanticism was realized on the design of an open space and surrounded building's.

지하철 콘크리트 BOX 구조물의 수화열에 의한 균열저감 대책 연구 (A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure)

  • 김은겸;윤석구;배상일;정재용;김현철;허정옥
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.425-428
    • /
    • 2006
  • The bigger of concrete strctures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box strucuture, the use of blended cement, the temperature of air and concrete, control joint, was considered and analysed by a three dimensional finite element method.

  • PDF

대기온도를 고려한 지하철 콘크리트 Box 구조물의 수화열에 의한 온도균열제어 대책 (A Counterplan of temperature crack control by a heat of hydration of Subway concrete box structure concerned External Temperature)

  • 노현섭;김은겸;양신추
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.581-584
    • /
    • 2007
  • The subway concrete box structure can`t establish expansion joint because of animal power delivery of the subway rail. In this case, As increase of structure volume, it is subjected to cause temperature crack. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, examined a condition of temperature crack occurrence by a heat of hydration concerned external temperature from analysing by a three dimensional finite element method.

  • PDF

콘크리트 BOX 구조물의 수화열에 의한 온도균열제어 대책 (A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure)

  • 김은겸;전찬기;전중규;배상일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.705-708
    • /
    • 2006
  • The bigger of concrete structures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, which is located in chloride attack region, the use of blended cement, the temperature of air and concrete, was considered and analysed by a three dimensional finite element method.

  • PDF

항내수질 개선을 위한 친환경 외곽시설에 관한 연구 (A Study on Environmentally Friend Counter Facilities for Improvement of Harbor Water Quality)

  • 김강민;강석형;유하상;김상훈
    • 한국항해항만학회지
    • /
    • 제27권2호
    • /
    • pp.233-238
    • /
    • 2003
  • 파랑에너지를 차단하고 항내 정온을 확보하기 위해 설치된 외곽시설인 방파제는 불투과성이기 때문에 항만을 폐쇄성으로 만들 수 있으며, 항내ㆍ외간의 해수교환은 급격히 감소될 수 있다. 항만개발의 최근 추세는 항내의 수질 보호와 친수성이 강조되어, 기존의 불투과성 방파제의 일부에 투과성으로 설계한 제체투과성 해수교환방파제를 설치하는 것으로 나타났다. 이 경우 외해의 에너지가 항내로 전달되어 항내 오염물질의 희석률 증대와 함께 외해로 배출되도록 하고 있다. 오염이 심화된 항만(남해 동부해안에 위치한 삼천포 구항)에서 항내 수질을 개선하기 위한 방안은 육상오염원을 제거하는 것이 최선이나, 폐쇄성이 큰 항만의 경우, 외해와의 해수순환을 강화시켜야만 한다. 즉, 기존의 항만에서의 항내 수질개선을 위해서 외곽시설의 일부에 해수소통구를 두는 방법이 가장 최선이라 할 수 있다. 본 연구에서는 항내 오염이 심각한 항만을 대상으로 하여, 해수소통구를 통한 해수순환 양상을 수치계산을 통해 검토하고 수반되는 해수교환율을 검토하였다. 본 연구에서는 유한 차분법으로 수치모델을 구성하였으며, 해수소통구 도입에 따른 항내의 해수순환 및 해수교환율을 평가하였다.

재생 유휴산업시설의 플레이스 브랜딩 방법 분석 (An Analysis of the Place Branding Methods for Regenerated Idle Industrial Facilities)

  • 조연주;신경주
    • 한국실내디자인학회논문집
    • /
    • 제24권1호
    • /
    • pp.54-63
    • /
    • 2015
  • This study aims to suggest the place branding methods applicable for regenerated idle industrial facilities. The place branding methods were analyzed by separating into hard branding methods and soft branding methods, and the results of the study are as follows: As for the hard branding methods, the exterior, outer wall materials and interior materials of the building and industrial equipment are preserved to revive the historicity of the building. In order to organize a differentiated space, it is important to create the convenience space such as cafes, experience space, lounge, and restaurants as well as the space for the operation of the programs. The building itself is utilized as a landmark or the iconic facility such as the winding tower or chimney is utilized as a landmark. As the methods of introducing natural elements, there is a need to create the resting space, law area and water space where trees can be planted and landscape can be viewed, and the development of tourism products utilizing the peripheral resources and the link of programs are also important. As for the soft branding methods, the provision of programs where a variety of art genres and the sense of place are reflected and the programs linked to the region is needed, and the story of place can be shared by storytelling utilizing the work and programs reflecting the sense of place. In addition, the content development and physical improvement of facilities reflecting the needs of visitors and the establishment of the organic collaboration system of a variety of subjects are needed for the sustainability of place.