• 제목/요약/키워드: Outer voltage regulation loop

검색결과 6건 처리시간 0.019초

약계자 영역에서 전동기 상수변동에 둔감한 SPMSM의 새로운 약계자 제어기 (A New Robust SPMSM Control to Parameter Variations in Flux Weakening Region)

  • 김장목;송종환;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.264-268
    • /
    • 1999
  • A new implementation strategy for the flux weakening control of a Surface Mounted Permanent Magnet Synchronous Motor (SPMSM) is proposed. It is implemented based on the output of the synchronous PI current regulator-reference voltage to PWM inverter. The onset of flux weakening and the level of the d-axis current are adjusted by the outer voltage regulation loop to prevent the saturation of the current regulator. The characteristics of this flux weakening scheme include no dependency on the machine parameters, the guarantee of current regulation on any operating condition, and fast transition into and out of the flux weakening mode. Experimental results at various operating conditions including 4-quadrant operation are presented to verify the feasibility of the proposed control scheme.

  • PDF

Two-loop Hysteretic Control of $3^{rd}$ Order Buck Converter

  • Veerachary, M.;Sharma, Deepen
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.310-317
    • /
    • 2007
  • In this paper, an analysis and hysteretic controller design of a $3^{rd}$ order buck converter is presented. The proposed hysteretic controller consists of an inner current-loop, just like the conventional cascade control scheme, and an outer voltage-loop for load voltage regulation. Although it is possible to include an inner current loop from different branches of the converter, from the feasibility and operational point of view, the load side capacitor current would be the better choice. The addition of an inner current-loop improves the dynamic performance of the converter while preserving the robustness of the hysteretic control. The controller formulation and closed-loop converter performance analysis are validated through computer simulations. Few experimental results of the proposed converter are given and compared with the buck converter.

비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계 (A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads)

  • 이우철;이택기
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.

PWM DC-AC Converter Regulation using a Multi-Loop Single Input Fuzzy PI Controller

  • Ayob, Shahrin Md.;Azli, Naziha Ahmad;Salam, Zainal
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.124-131
    • /
    • 2009
  • This paper presents a PWM dc-ac converter regulation using a Single Input Fuzzy PI Controller (SIFPIC). The SIFPIC is derived from the signed distanced method, which is a simplification of a conventional fuzzy controller. The simplification results in a one-dimensional rule table, that allows its control surface to be approximated by a piecewise linear relationship. The controller multi-loop structure is comprised of an outer voltage and an inner current feedback loop. To verify the performance of the SIFPIC, a low power PWM dc-ac converter prototype is constructed and the proposed control algorithm is implemented. The experimental results show that the SIFPIC performance is comparable to a conventional Fuzzy PI controller, but with a much reduced computation time.

무정전 전원공급장치 적용을 위한 PWM 인버터의 Digital 실시간 제어 (Real Time Digital Control of PWM Inverter for Uninterruptible Power Supply(UPS) application)

  • 민완기;이상훈;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 전문대학교육위원 P
    • /
    • pp.56-60
    • /
    • 1999
  • This paper presents the high performance real time control system of PWM inverter for uninterruptible power supply(UPS). This system is based on a digital control scheme which calculates the pulse widths of the inverter switches for the next sampling time in digital signal processor(DSP). A PI compensator is used to eliminate the voltage error caused by the difference between the actual values of LC filter and those designed. Double regulation loops which are the inner current loop and the outer voltage loop are used to make the transient response time reduce in load disturbance and nonlinear load. This method makes it possible to obtain better response in comparison to conventional digital control system. The proposed scheme provides good performance such as stable operation, low THD of the output voltage, and good dynamic response for load variations and nonlinear load.

  • PDF

약계자 영역에서 외부 전압제어 루프에 의한 매입형 영구자석 동기전동기의 최대 토오크 운전 (Outer Voltage Regulation Loop for Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in the Flux)

  • 김장목;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.121-123
    • /
    • 1997
  • A novel flux-weakening scheme for the Interior Permanent Magnet Synchronous Motor (IPMSM) is proposed. This is implemented based on the output of the synchronous PI current regulator-reference voltage to the PWM inverter. Attractive features of this flux weakening scheme include no dependency on the machine parameters, the guarantee of current regulation at any operating condition, and smooth and fast transition into and out of the flux weakening mode without a discontinuity. Experimental results are presented to verify the feasibility of the proposed control scheme.

  • PDF