• Title/Summary/Keyword: Outdoor-Unit

Search Result 238, Processing Time 0.028 seconds

A Comparative Study on Space Organization of Kindergarten in Korea and Japan (한국과 일본 유치원의 공간구성 실태 비교)

  • Park, Sung-Chul;Song, Byung-Joon;Cho, Jin-Il
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.15 no.1
    • /
    • pp.19-29
    • /
    • 2016
  • This study aims to find a direction for desirable space organization in future Korean kindergartens by analyzing the current status of space organization in Japanese kindergartens. This study includes comparisons and analyses of Korean and Japanese curricula, facility standards on the national level and standards of national subsidy, current numbers of kindergarteners and preschoolers, and changes in kindergarten facilities over the last 5 years. Six kindergartens each in Korea and Japan, which were constructed after 2011 or are recommended as being good in space organization and kindergarten planning, are selected. The contents of space organization analysis are 'entry and placement, outdoor space', 'space program,' and 'plan design and organization of unit space'. In conclusion, in terms of space organization, Korean and Japanese kindergartens are very similar to each other. However, Japanese kindergartens have more outdoor space about $9.75m^2$ and lot area about $11.89m^2$ than Korean kindergartens. The extra space was used to educate students in various contents regarding social network and physical activity. Furthermore, in Japan, special spaces such as "atelier classes" and "PTA" were used for various types of education. Based on the results of the study will be developed, such as specific models and guidelines for the improvement of facilities Korea kindergarten.

An Automatic Back-Light Brightness Control System of Mobile Display Using Built-In Photo Sensor (내장형 광센서를 이용한 모바일 디스플레이의 자동 광원 밝기 조정 시스템)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.713-716
    • /
    • 2008
  • This paper presents an automatic back-light brightness control system for mobile displays. One of the most important factors in mobile display is the power consumption due to the limited and movable power source. More than 80% of power of the LCD display is consumed by LED bark-light unit (BLU). The target brightness also becomes higher because of its moving picture and high resolution image, so there are some side effects for not only excessive power consumption but also ergonomic inconvenience in dark environment. To prevent this discomfort and reduce power consumption, this paper proposes automatic brightness control (ABC) technique in mobile displays. Developed system contains TFT-LCD panel with built-in photo sensor, driver IC capable of controlling photo sensor, and BLU. Since the photo sensor array built in panel detects automatically outdoor ambient light intensity, the power of BLU in dark environment is reduced. Developed ABC system showed reduced power consumption of 50% in dark environment. We believe that the proposed system is very useful to control power of mobile TFT-LCD.

  • PDF

Effect of Interference Mitigation Technique and Performance Analysis for Small Cell in Homogeneous Networks (동종네트워크 상에서 셀 소형화 간섭 완화 기법 및 성능 분석)

  • Jang, Ye-Ok;Cho, Eun-Hyung;Hong, Een-Kee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.10
    • /
    • pp.937-945
    • /
    • 2014
  • As various services requiring high data rate are supported by introducing LTE/LTE-adv., mobile traffic increases rapidly. To cope with the continuous growth of traffic demand, small cell technology is considered as one of the most promising one. Small cell can increase system capacity by increasing the number of base stations with reduced cell radius. In this paper, we analyze the effect of cell densification with small cells in terms of SINR and average UE throughput considering cell split and the number of UE per unit area. As the cell becomes smaller, SINR degradation arises from high ICI(Inter Cell Interference) and we evaluate the effect of interference mitigation scheme in small cell environment where the proper interference mitigation technique is applied.

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

Development of Deterioration Diagnosis System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화진단시스템 개발)

  • 김성덕;이승호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.43-50
    • /
    • 2000
  • Design and experiments of a nondestructive testing system with a solenoid eddy current sensor to inspect deterioration of ASCR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wires) usually used in HV overhead distribution lines in domestic areas in presented in this paper. Through corrosion mechanisms and deterioration results for ACSR-OC conductors are examined, it is shown that corrosion may lead to the reduction of the effective cross section area of conductors is proposed. The measurement system consisting of a constant current source with a RF frequency, a signal processing unit and a motor driver/ controller is designed and implemented. This instrument has such capabilities as detecting the sensor output and estimating diameter change of the testing conductors, continuously. As a result, it was verified that such corrosion detector system with an eddy current sensor can be shown good effectiveness for estimating the serious faults due to deterioration in overhead distribution lines and giving an early warming before severe aged conductor may lead to fail.

  • PDF

A Research on the Housing Safety Threat Condition of the Elderly in Rural Area (농촌 고령자의 안전위협에 관한 주거실태 조사연구)

  • Kang, Hye-Kyung;Cho, Hee-Keum;Lee, Mi-Young;Eum, Ga-Young
    • Journal of the Korean housing association
    • /
    • v.25 no.5
    • /
    • pp.21-32
    • /
    • 2014
  • This research intends to discover the housing conditions of the elderly in rural area in South Korea, and identify measures to improve the conditions for an independent and safe life of seniors. This research conducted both survey research and experimental study. The survey interviewed 1,000 elderly people over 65 in farming areas across the country based on random selection from Census 2010 and sampling by regional size and administrative unit (Eup, Myeon, Li) to reflect the regional characteristics more accurately. The data was analyzed using SPSS 18.0 program. The experimental study identified the housing elements that may threaten the life of seniors based on a complete survey on households of elderly people over 65 in a selected typical rural village. As a result, the most inconvenient and threatening factor in the housing facilities appears to be the floor level difference. It was identified that most houses had the risk of falling due to the differences of the floor level between indoor and outdoor, and slippery floor materials. The squat toilets also bring inconvenience not only to the seniors with limited mobility but also to healthy elderly people. In particular, as most bathroom doors opened inward, it may be difficult to escape from or rescue someone in an emergency of falling, fainting or exhaustion.

Characteristics of Interior Space and Planning for Elderly Day Care Center in Korea (우리나라 노인주간보호시설의 실내공간 특성과 계획안)

  • 이선주;권오정
    • Journal of Families and Better Life
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • Day care center for the elderly is an alternative for community care for frail elderly who need social participation and physical cares and services outside the family. The purpose of this study was to identify the present situation of day care center for the elderly and to suggest desirable interior space plans for elderly day care center. Data were collected by two ways; a mail survey and case studies of existing day care centers. Five cases of day care centers were analyzed to find out Physical and space problems, available programs and services. Also, the staffs in 96 day care centers for the elderly in nationwide were selected for a mail survey and 68.8 percentage of all was collected and analyzed. From the result of case studies, narrow space and lack of accessibility features for wheelchair or other prosthetic devices were the major problems. From the result of a mail survey analysis, the elderly users were over 73 years old, and high proportion had suffered from dementia and apoplexy Also, staffing ration was 1:7 In other words, one staff was caring of 7 old people, and supporting staff was insufficient. Therefore, supportive, therapeutic environment Was more important issue to improve quality of care. Separate program room and outdoor space, lounging space, treatment room by gardening, separate counselling room, bedroom, a simple kitchen unit, staff office, separate physical treatment room, resting room for staff was indicated more necessarily. When priority of planning interior space was safety followed by accessability and convenience, it was also reported that sire of each room was generally narrow. The most serious problem in interior space was the lack and narrowness of space, and accessible features for mobility. Based on the literature review and the findings of this study, two types of floor plans for elderly day care center were suggested;‘a mixed type for the elderly with and without dementia’and‘a separate type for the elderly with dementia.’The main goals for designing interior space for two types of elderly day care center were to provide safe environment, encouraging environment for remaining abilities of users, sanitary environment, therapeutic environment, familiar environment, and socially-encouraging environment. The recommendations for further studies were suggested.

Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System (간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구)

  • Yoo, Seong Yeon;Kim, Tae Ho;Kim, Myung Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.9
    • /
    • pp.743-749
    • /
    • 2015
  • The purpose of this study is to predict the performance of an indirect evaporative cooling system, and to evaluate its energy saving effect when applied to the exhaust heat recovery system of an air-handling unit. We derive the performance correlation of the indirect evaporative cooling system using a plastic heat exchanger based on experimental data obtained in various conditions. We predict the variations in the performance of the system for various return and outdoor air conditioning systems using the obtained correlation. We also analyze the energy saving of the system realized by the exhaust heat recovery using the typical meteorological data for several cities in Korea. The average utilization rate of the sensible cooling system for the exhaust heat recovery is 44.3% during summer, while that of the evaporative cooling system is 96.7%. The energy saving of the evaporative cooling system is much higher compared to the sensible cooling system, and was about 3.89 times the value obtained in Seoul.

Long-Term Evaluation of the Adequacy of Korean Diet to Meet the Protein-Energy Requirement of Young Korean Male Adult (한국인(韓國人) 단백질(蛋白質)-열량(熱量) 소요량(所要量)에 대(對)한 연구(硏究) (장기간급식(長期間給食)에 의(依)한 한국식이(韓國食餌)의 적정성(適正性)에 대(對)한 평가(評價)))

  • Ju, Jin-Soon
    • Journal of Nutrition and Health
    • /
    • v.14 no.4
    • /
    • pp.209-219
    • /
    • 1981
  • To evaluate long-term metabolic response of free-living Korean subjects consuming local sources adequately or slightly below habitual intake. Subjects, six male medical students aged 23-25 years were free-living, but consumed diets in the metabolic unit. They were healthy as determined from medical laborarory tests. They belong to the Korean middle-class. Temperature of outdoor during study were ranged between -2 to $26^{\circ}C$, whereas the indoor were $18-22^{\circ}C$. Animal protein ranged between 25-30% of total calorie. The three meals and a vitamin supplement to meet recommendation were given daily. Three 50day periods following the design were used to test the protein-energy adequacy of the diet. Urinary nitrogen excretion was measured daily. Fecal samples were pooled for the last 5 days of each week. Nitrogen balance was computed using 5mg N/Kg skin and miscellaneous losses. Body weight was measured daily. The study was covered on 126 metabolic observations weekly. Body weight changes were relatively stable with the energy intake of 37-44Kca1/kg, and N-balances were also relatively stable, but it was influenced by physical and or mental stress somehow. It could be assumed that the mean protein and energy requirement were $190{\pm}10mg$ N/Kg with $41{\pm}2$ Kcal/kg, and the mean digestibility of protein was 81% on these subjects with the experimental conditions. The protein requirement, however, could be cut down somewhat with some limited increaing of energy intake under parameters of N-balance and maintaining body weight. It was also observed a tendency of the requirement were getting smaller with the increase of body size.

  • PDF

Investigation on Concentrations and Correlations of Airborne Microbes and Environmental Factors in the General Hospital (종합병원내 부유 미생물 농도 및 환경 요인과의 상관성 조사)

  • Lee, Chang-Rae;Kim, Ki-Yeon;Kim, Chi-Nyon;Park, Dong Uk;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.45-51
    • /
    • 2005
  • This survey was performed to measure concentrations of airborne microbes, utilizing the six-stage cascade air sampler, according to the sampling site and time in the general hospital and to evaluate the degree of correlations between airborne microbes and environmental factors. Besides the main lobby, airborne microbes and environmental factors were not significantly different between the forenoon(9:00-10:00 AM) and afternoon(2:00-3:00 PM). Concentrations of airborne bacteria and fungi were 404 and $156CFU/m^3$ in the main lobby, 188 and $56CFU/m^3$ in the intensive care unit, 323 and $96CFU/m^3$ in the ward, 239 and $127CFU/m^3$ in the laboratory, and 139 and $33CFU/m^3$ in the newborn baby room, respectively. As a result, the level of airborne microbes was significantly highest in the main lobby and lowest in the newborn baby room(p<0.05). Outdoor airborne microbes concentrations were significantly lower than those of the sampling sites in the general hospital except for the newborn baby room(p>0.05). It was observed that temperature, relative humidity and carbon dioxide in the general hospital had generally positive correlation with airborne microbes. However, there was no correlation between the odor index level and airborne microbes.