• Title/Summary/Keyword: Outdoor-Exposure

Search Result 306, Processing Time 0.027 seconds

Applicability as a Dancheong Pigment Raw Materials of Korean Low Grade Kaolin (국내산 저품위 고령토자원의 단청안료 원료로써의 활용 가능성)

  • Moon, Dong Hyeok;Han, Min Su;Cho, Hyen Goo;Kim, Myoung Nam;Kim, Jae Hwan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.179-190
    • /
    • 2016
  • X-ray diffraction analysis, chromaticity measurement, execution and evaluation by Dancheong artisan, accelerated weathering test, and fire resistance test were conducted to test the applicability as a Dancheong pigment raw materials of Korean low grade kaolin in cultural properties. The ores that feldspar rich and composed of fine particles (< $38.1{\mu}m$) showing advantageous for the inherent purpose of the white pigment than that of high grade kaolin. And the test of whiteness, concealment force, outdoor exposure durability and fire resistance shows similar or better result than existing products (Hobun and Sanhwa jidang). In conclusion, it is expected that the use of fine feldspar rich white soil and low-grade kaolin can be used as a white pigment raw materials which have similar to better material properties and economic efficiency than existing products.

A Study on Development of Power Analysing Device for PV Module (태양전지 모듈의 발전량 분석 장치 개발에 관한 연구)

  • Moon, Chae-Joo;Kwak, Seung-Hun;Jang, Yeong-Hak;Kim, Tae-Gon;Kim, Eui-Sun;Kim, Tae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1~10 of M), (11~20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is-2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by $1^{\circ}C$, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by-0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced.

Factors Affecting the Morbidity Related to Respiratory Dieseases in Urban Korea (한국 도시의 만성호흡기 질환 이환율에 영향을 주는 요인)

  • Han, Sung-Hyun;Park, Jae-Sung;Seo, Seung-Hee;Yoon, Jee-Eun;Jee, Sun-Ha
    • Korea journal of population studies
    • /
    • v.28 no.2
    • /
    • pp.205-217
    • /
    • 2005
  • Purpose: To evaluate the factors affecting hospital utilization for respiratory diseases by ecological study design and GIS tool. To raise the social concern for respiratory disease by the result. Methods: Hospital admission data supported by national health insurance cooperation were transformed to spread sheet data format and combined with air monitoring dataset. Air pollution data were collected from the annual report of air monitoring published by Korea Ministry of Environment. Socioeconomic statistics including population density, age distribution, forest ratio etc.. were filed using Korea National Statistical Office database. Multiple linear regression analysis was performed to evaluate the factors affecting hospital utilization for respiratory diseases. Analytical unit was 52 cities. Results: The factors affecting hospital utilization for respiratory diseases were the proportion of population 60 years and over, seaside city, $O_3$ level, smoking rate. Conclusions: However, outdoor pollutants monitoring data and smoking rate have weakness in reflecting individual exposure. Further research is required to propose more illustrative means to evaluate causal relationship between air pollution and respiratory health effect factors.

Long-Term Performance of Amorphous Silicon Solar Cells with Stretched Exponential Defect Kinetics and AMPS-1D Simulation (비정질실리콘 태양전지에 대한 장시간 성능예측: 확장지수함수 모형 및 컴퓨터 모의실험)

  • Park, S.H.;Lyou, Jong-H.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.4
    • /
    • pp.219-224
    • /
    • 2012
  • We study for long-term performance of amorphous silicon solar cells under light exposure. The performance is predicted with a kinetic model in which the carrier lifetimes are determined by the defect density. In particular, the kinetic model is described by the stretched-exponential relaxation of defects to reach equilibrium. In this report, we simulate the light-induced degradation of the amorphous silicon solar cells with the kinetic model and AMPS-1D computer program. And data measured for outdoor performances of various solar cells are compared with the simulated results. This study focuses on examining the light-induced degradation for the following amorphous silicon pin solar cells: thickness${\approx}$300 nm, built-in potential${\approx}$1.05 V, defect density (at t=0)${\approx}5{\times}10^{15}cm^{-3}$, short-circuit current density (at t=0)${\approx}15.8mA/cm^2$, fill factor (at t=0)${\approx}0.691$, open-circuit voltage (at t=0)${\approx}0.865V$, conversion efficiency (at t=0)${\approx}9.50%$.

The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation (다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사)

  • Joen, Jeong-In;Lee, Hye-Won;Choi, Hyun-Jin;Jeon, Hyung-Jin;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

Surface Deterioration Diagnosis of Taejong Heonreung Sindobi Monument using Nondestructive Method (비파괴 기법을 이용한 태종 헌릉 신도비의 표면 훼손도 진단)

  • Lee, Myeong-seong;Park, Sung-mi;Chun, Yun-gun;Lee, Sun-myung;Lee, Jae-man
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.4
    • /
    • pp.90-107
    • /
    • 2013
  • The Stone Monument of Taejong King in Heonreung Royal Tomb, Seoul was originally erected in 1424 to pay a tribute to Bang Won Lee's achievement who was named Taejong, the Third King of Joseon Dynasty. The monument has been damaged by Japanese Invasion of Korea in 1592 so that another monument was newly made and erected together with the original monument in 1695. The original monument was made of medium-grained biotite granite for the turtle base and medium-grained milky white crystalline limestone for the stele body and the top stone. The turtle base of the original monument is destroyed beyond the original shape and inscription due to irregular shaped breaking and a set of longitudinal crack. Analyzing the deterioration degree by using nondestructive methods, the 88 percentage of the front area and 38 percentage of the back area of the monument are damaged, and the lower part of the stele body is dominantly deteriorated especially due to the combination of discoloration and physical deterioration. The new monument in 1695 is also made of granite and limestone. The weathering indices of the turtle base and stele body stones by the calculation from ultrasonic velocity are 0.10 and 0.74, respectively. This is because the original monument is presumed to be degraded by heat shock and physical attack during the Japanese war, and the long-term outdoor exposure accelerated the weathering of the monument afterward without protective shelter.

Interpretation on Internal Microclimatic Characteristics and Thermal Environment Stability of the Royal Tombs at Songsanri in Gongju, Korea (공주 송산리 고분군 내부의 미기후 특성 및 온열환경 안정성 해석)

  • Kim, Sung Han;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.35 no.2
    • /
    • pp.99-115
    • /
    • 2019
  • The Royal Tombs at Songsanri is one of the most important historic site for ancient historical study in Korean Peninsula. Since the excavation of the tombs, continuous exposure to the outside environment and the negative effects of the artificial air conditioning system have caused significant threats to the thermal environment stability of the tombs. Unlike the outside temperature that shows significant differences according to seasonal changes, the burial chamber of the tombs had a relatively stable temperature range of 11.4 to $22.2^{\circ}C$ throughout the year, and the standard deviation of temperature was within 3.5. It was revealed that major factors affecting the microclimate of the tombs were inflow of outdoor air, wind direction and speed, and all of them had closely related to airtightness of the tombs. The solar radiation was in inverse proportion to the thickness of burial mounds, and thus Royal Tomb of King Muryeong, which has the thickest burial mound, was least affected by solar radiation. Especially, microclimate of the tombs caused to the highest influence with artificial environmental changes due to access by people, which varied in proportion to the number of accessed people and time of stay. Currently, the inside of the tombs are sealed and always in saturated condition, it is very vulnerable to dew condensation. As a result of analyzing the possibility of condensation in each tomb, all the tomb No. 5, tomb No. 6 and Royal Tomb of King Muryeong had condensation most of the time throughout the year. It is required to make a proper conservation environment for the Royal Tombs at Songsanri.

A Study on the Basic Physical Properties of Water-Soluble Rubber Asphalt-based Coating Waterproofing for Exterior Application (수용성 고무 아스팔트계 도막방수재의 실외 적용을 위한 기본 물성 연구)

  • Kang, Hyo-Jin;Youn, Sung-Hwan;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.553-561
    • /
    • 2020
  • Water-soluble rubber asphalt-based waterproofing material, which is one of the waterproofing materials for building structures, is mainly used indoors (toilet, kitchen, balcony, etc.). In general, asphalt-based materials are used for non-exposed installation, rather than as exposed type as they do not deviate from their usual basic black pigmentation, and water-soluble rubber asphalt-based coating waterproofing materials are basically limited to indoors because of their low physical properties. Accordingly, in order to improve the tensile and elongation properties, a silane coupling agent, an inorganic filler, and a processor oil w ere added to improve the physical properties, and accordingly, the basic physical properties of the outdoor coating waterproofing material quality standard were analyzed. As a result, the water-soluble rubber asphalt coating waterproofing material compared with the exposure quality standard showed a result that exceeded the basic physical property quality standard of silicone rubber in all items under test evaluation, but the tensile strength and tear strength of the first class of urethane rubber were chloroprene. It was found that the performance compared to the quality standards of rubber-based tear strength was about 34.2% to about 40.8%.

Evaluation of Anti-Stain Efficacy of Myoung-oil, Traditional Coating Agent (전통 마감제인 명유의 방미효력 평가)

  • Yoon, Sae-Min;Park, Yonggun;Jeon, Woo-Seok;Lee, Hyun-Mi;Hwang, Wonjoung;Nam, Kee Dal;Park, Jae-Gwan
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.505-510
    • /
    • 2020
  • In this study, the anti-stain effect of the Traditional Myoung-oil, which has been reproduced through traditional method, the Clean Myoung-oil, which was developed in an eco-friendly method through scientific analysis of Traditional Myoung-oil, and the perilla oil, which is the raw material of Myoung-oil and is currently used as a finishing agent when repairing wooden cultural properties was evaluated. As a result of the evaluation, perilla oil showed almost no anti-stain effect, whereas both types of Myoung-oil showed high anti-stain effect. However, it was confirmed that the anti-stain effect was significantly reduced after 4 weeks of exposure to the strain when Myoung-oil was diluted with terpene oil, a natural solvent. Thus, it was considered that the amount of treatment in the wood affected the anti-stain effect of Myoung-oil. In other words, in constructing wooden buildings, Myoung-o il is more suitable as a finishing agent to suppress mold growth than perilla oil. And, in order to increase the applicability of Myoung-oil, it is suggested that additional research on the optimal treatment amount and treatment method that can inhibit mold growth inhibition in outdoor environments is necessary.

Effects of Polyethylene Glycol Treatment for Improvement of Preservative Penetration and Prevention of Drying Check of Preservative Treated Round Post (방부처리 원주가공재의 방부제 침윤도 향상 및 건조 할렬 방지를 위한 폴리에틸렌 글리콜 처리 효과)

  • Lee, Jong-Shin;Yoon, Sun-Mi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.27-32
    • /
    • 2002
  • We investigated the effect of polyethylene glycol(PEG) treatment of preservative treated green japanese cedar(Cryptomeria japonica) round posts on their preservative penetration and check formation during the air drying. The round rods were dip-treated in 10% preservative solution of Basilit CFK for 1 day, followed by application(3, 5, and 10 times) with 50% PEG-400 solution, and then dried for 30 days under natural conditions. The rate of preservative penetration into sapwood was a low by 23.2% without PEG treatment, whereas that was a high by about 51.2~64.5% with PEG treatment. From these results, it was assumed that PEG played an affirmative role in the penetration of preservative components loaded onto the surface of round rods by dipping. During the air drying, the formation of drying checks decreased significantly with increasing application times of PEG. Even though some drying checks in PEG treated rods were developed, the number and size of checks was reduced remarkably by PEG treatment. After 2 months of outdoor exposure, PEG treatment failed to reduce checking in preservative-treated rods whereas finishing of polyurethane resin lacquer after PEG treatment was significantly effective in preventing check development.