Development of HVAC System to Lower the Conveyance Energy and Building Height (반송동력과 건물층고 저감형 공조시스템 개발)

  • 김정엽;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

Photooxidation of BR Vulcanizate Using High Pressure Mercury Lamp

  • Kim, Eunha;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.50 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Polybutadiene rubber (BR) has been well known that its physical and chemical properties are changed when it is exposed to ultraviolet light undergoing photooxidation. In this study, photooxdiation process of BR vulcanizate was investigated using a high pressure mercury lamp used as an outdoor lighting, which has high UV radiation efficiency and reasonable cost. Discoloration and crack formation of photooxdized BR vulcanite surface were examined using an image analyzer. Change of chemical functional groups of BR vulcanite surface by photooxidation was investigated using ATR-FTIR, and variation of the crosslink density with the UV irradiation time was investigated. By increasing the UV irradiation time, the crosslink density steeply increased after a period of time and did not increase any more. Formation of hydroxyl (~OH) and carbonyl (~C=O) groups on the BR vulcanizate surface increased and the1,4-cis unit was converted to the 1,4-trans unit as the photooxidation was proceeded.

An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House (주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구)

  • Lee, Choong-Kook;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.

Present Condition and Preferences on Well-being Elements in Apartments (아파트의 웰빙요소 도입현황과 선호도)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.61-72
    • /
    • 2007
  • The purposes of this study were to summarize the concept of well-being and well-being apartment, to grasp the present condition of apartments which were introduced with well-being elements, and to find out the consumer preferences on well-being elements for apartment planning. Library and internet surveys were performed to summarize the concept of well-being and well-being apartment and to grasp the present condition of apartments which were introduced with well-being elements. Questionnaire survey was carried out from 2nd to 22nd of June 2005, to investigate the preferences on well-being elements for apartment planning. The respondents were 250 residents who are from thirties to fifties and living in urban area. As results, respondents think that 'living for health of body and mind' about concept of well-being and 'certificated apartments by green building rating system' or 'apartments introduced ecological factor' about concept of well-being apartment. They answered that 'yes' about 'Do you have intention to buy well-being apartment?'. The elements in aspect of complex planning having the preference were revealed that promenade for complex design, ecological garden or walking space for landscape design, outdoor exercise space for outdoor design, and security system for foundation equipment. The elements having the preference in aspect of public facilities were fitness room for sports & health facility and study room for cultural facility. The preferred elements in aspect of building and unit design were roof garden for building design, multi-functional room for unit floor plan, natural surface material for interior surface, ventilation system for indoor environment, control system for home automation, and food waste machine for home electronics.

A Study on the Chronological Characteristics of the Strategy for House Marketing in terms of the Apartment Advertisements in Busan.Kyungnam area - focused on Busanilbo newspaper advertisements from 1970's to 1990's - (부산.경남지역 아파트 분양광고에 나타난 주택판매 전략의 연도별 특성에 관한 연구 - 1970년대부터 1990년대까지 부산일보 분양광고를 중심으로 -)

  • 최임주
    • Korean Institute of Interior Design Journal
    • /
    • no.33
    • /
    • pp.36-45
    • /
    • 2002
  • The purpose of this study is to investigate the chronological characteristics of the strategy for the house marketing in terms of the apartment lots for sale advertisements appeared to be from 1970's to 1990's in Busan·Kyungnam area. For the analysis of the newspaper advertisement, a new residence environmental indication is introduced to this research as referring to the existing research data. With this indication, therefore, this study is to examine what contents of the advertisements are. Moreover, as analyzing how frequently the advertisements have been inserted in the newspaper, it shows the characteristics which the construction industry has planned for sale of apartment in lots. The results are as follows; First, the frequency of the appearance in the newspaper about each unit and block in an apartment complex has been on the decrease. On the other hand, the importance about the surrounding area has been on the increase during the period. It shows that consumer require more about the surrounding area issues than each unit itself. Second, in the case of the outdoor space in the apartment complex, the frequency of the appearance in the newspaper has been kept a certain levels during the period. It is clear that the consumers have been concerned about the outdoor space throughout the period. Third, the most important issue is the qualify of site location, such as the benefits of the traffic, the levels of the education environment, the natural environment of the apartment complex and so forth. The frequency of the appearance in the newspaper has been kept increasing since 1970's in the advertisement. It clearly shows that this issue has been standardized for purchasing a house.

Localization Performance Improvement for Mobile Robot using Multiple Sensors in Slope Road (경사도로에서 다중 센서를 이용한 이동로봇의 위치추정 성능 개선)

  • Kim, Ji-Yong;Lee, Ji-Hong;Byun, Jae-Min;Kim, Sung-Hun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.67-75
    • /
    • 2010
  • This paper presents localization algorithm for mobile robot in outdoor environment. Outdoor environment includes the uncertainty on the ground. Magnetic sensor or IMU(Inertial Measurement Unit) has been used to estimate robot's heading angle. Two sensor is unavailable because mobile robot is electric car affected by magnetic field. Heading angle estimation algorithm for mobile robot is implemented using gyro sensor module consisting of 1-axis gyro sensors. Localization algorithm applied Extended Kalman filter that utilized GPS and encoder, gyro sensor module. Experiment results show that proposed localization algorithm improve considerably localization performance of mobile robots.

Design Guidelines of Digital Home Based on Digital-Related Human Behavior (디지털과 관련한 인간의 생활행태에 기초한 디지털 홈의 디자인 방향)

  • Oh Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.1
    • /
    • pp.81-90
    • /
    • 2005
  • This study was intended to suggest the design guidelines of digital home on the basis of digital-related human behavior. In order to achieve this, what and how often internet was used in the home, how living pattern and space usage was changing according to digitalization were examined and lastly, the design guidelines of digital home based on these findings were suggested. The subjects were 400 housewives who lived In 85m'-sized housing unit of the new apartment complex in Busan. They were average age of 38 and their eldest children were in the stage of elementary schooling or preschooling. Many of them had relatively high educational level and middle income level. The results of the study were as follows; 1) The respondents used internet more frequently for information searching, children's education, and Internet shopping. Therefore, it would be desirable to divide zoning of housing unit into space for routine activities, space for working, and for cultural activities. 2) Digitalization changed human living pattern like follows; it reduced time of shopping, information searching, banking, and going out. Also, it increased time of spending alone, watching movie, and playing game. Therefore, digital home should be designed to facilitate social Interaction between family members, cultural and recreational activities, and indoor or outdoor exercise within each housing unit or in apartment complex.

Refrigerant Amount Detection Technology for System Air-Conditioner Using Design of Experiment (실험계획법을 이용한 시스템에어컨의 냉매량검지 기술개발)

  • Lee, Soo-Young;Takeichi, Hisashi;Tae, Sang-Jin;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • This paper is suggesting a new technology for refrigerant amount detection of a system air-conditioner installed under various installation conditions. System air-conditioner was introduced to domestic market first in 2000. It consists of one or a series of outdoor units and a number of indoor units connected with single pipe line to the outdoor unit. The system can vary the capacity from 2.0 kW to 186 kW. For the system Installed under long and high-elevated condition, about 100 kg of refrigerant is charged in the whole system. In this paper, the new technology RAD (Refrigerant Amount Detection) with edge technology of refrigerant cycle control and measurement of a system air conditioner was developed and investigated for its application for the various installation conditions.