• 제목/요약/키워드: Outdoor tests

검색결과 193건 처리시간 0.026초

투명방음판의 품질기준 설정에 관한 연구(2) - 음향 특성 및 내후성 평가 (Study on Quality Criteria for Transparent Soundproof Panels(2) - Sound Insulation Characteristics and Evaluation of Weatherability)

  • 장태순;김철환;황철호
    • 한국소음진동공학회논문집
    • /
    • 제22권11호
    • /
    • pp.1099-1105
    • /
    • 2012
  • Transparent noise barrier panels have the advantages of transmitting light to nearby residents and allowing drivers to orientate themselves by providing views of the surrounding area. To develop guidelines on quality criteria for transparent soundproof panels, their sound transmission loss and weatherability were experimentally investigated. In Korea, the sound transmission loss of noise barrier panels should be more than 25 dB at 500 Hz and 30 dB at 1000 Hz. The transmission loss tests of transparent panels were performed in accordance with KS F 2808. Typically, plastic materials suffer from color changes when exposed to ultraviolet(UV) light over extended periods. Therefore, weathering of plastics is one of the most important properties for outdoor applications. Protection against UV radiation and weathering is usually accomplished by using UV stabilizer additives or coatings. Transparent materials for soundproof panels were examined through accelerated weathering tests and their weathering resistances were evaluated from changes in yellowness index.

외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger)

  • 김내현;조홍기
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

Formal Validation Method and Tools for French Computerized Railway Interlocking Systems

  • Antoni, Marc
    • International Journal of Railway
    • /
    • 제2권3호
    • /
    • pp.99-106
    • /
    • 2009
  • Checks and tests before putting safety facilities into service as well as the results of these tests are essential, time consuming and may show great variations between each other. Economic constraints and the increasing complexity associated with the development of computerized tools tend to limit the capacity of the classic approval process (manual or automatic). A reduction of the validation cover rate could result in practice. This is not compatible with the French national plan to renew the interlocking systems of the national network. The method and the tool presented in this paper makes it possible to formally validate new computerized systems or evolutions of existing French interlocking systems with real-time functional interpreted Petri nets. The aim of our project is to provide SNCF with a method for the formal validation of French interlocking systems. A formal proof method by assertion, which is applicable to industrial automation equipment such as interlocking systems, and which covers equally the specification and its real software implementation, is presented in this paper. With the proposed method we completely verify that the system follows all safety properties at all times and does not show superfluous conditions: it replaces all the indoor checks (not the outdoor checks). The advantages expected are a significant reduction of testing time and of the related costs, an increase of the test coverage rate, an answer to the new demand of railway infrastructure maintenance engineering to modify and validate computerized interlocking systems. Formal methods mastery by infrastructure engineers are surely a key to prove that more safety is not necessarily more expensive.

  • PDF

오손도 자동측정장치 개발을 위한 기초연구 (A Fundamental Investigation to Develope a Automatic Apparatus for Contamination Measurement)

  • 최남호;한상옥
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.74-82
    • /
    • 2001
  • 유지·보수를 위한 비용과 선로의 안정성과 신뢰성을 저해하는 정전 등의 사고를 감소시키기 위해서는 오손정도에 대한 정확한 측정이 선행되어야만 한다. 그러나, IEC 60815 등을 통해 추천되어 많은 연구에 있어 사용되어 온 수동 필세법은 인력, 비용, 측정오차 등의 측면에 있어 많은 문제점을 지니고 있다. 이에 본 연구에서는 옥외 환경에서 사용되는 애자표면의 오손정도를 측정할 수 있는 새로운 형태의 자동측정장치의 개발을 목적으로 한 일련의 연구를 수행하고자 한다. 장비의 설계 및 평가를 위해 FLUX 2D를 이용한 시뮬레이션과 인공오손과 관련한 다양한 실험을 수행하였다. 이와 같은 노력의 결과, 새로운 형태의 오손도 자동측정장치의 개발에 있어 중요한 것으로 사려되는 몇몇 결론을 얻을 수 있었다.

  • PDF

청각장애인을 위한 웨어러블 기기의 위험소리 검출 엔진 설계 (A Design of Dangerous Sound Detection Engine of Wearable Device for Hearing Impaired Persons)

  • 변성우;이석필
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1263-1269
    • /
    • 2016
  • Hearing impaired persons are exposed to the danger since they can't be aware of many dangerous situations like fire alarms, car hones and so on. Therefore they need haptic or visual informations when they meet dangerous situations. In this paper, we design a dangerous sound detection engine for hearing impaired. We consider four dangerous indoor situations such as a boiled sound of kettle, a fire alarm, a door bell and a phone ringing. For outdoor, two dangerous situations such as a car horn and a siren of emergency vehicle are considered. For a test, 6 data sets are collected from those six situations. we extract LPC, LPCC and MFCC as feature vectors from the collected data and compare the vectors for feasibility. Finally we design a matching engine using an artificial neural network and perform classification tests. We perform classification tests for 3 times considering the use outdoors and indoors. The test result shows the feasibility for the dangerous sound detection.

A low cost miniature PZT amplifier for wireless active structural health monitoring

  • Olmi, Claudio;Song, Gangbing;Shieh, Leang-San;Mo, Yi-Lung
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.365-378
    • /
    • 2011
  • Piezo-based active structural health monitoring (SHM) requires amplifiers specifically designed for capacitive loads. Moreover, with the increase in number of applications of wireless SHM systems, energy efficiency and cost reduction for this type of amplifiers is becoming a requirement. General lab grade amplifiers are big and costly, and not built for outdoor environments. Although some piezoceramic power amplifiers are available in the market, none of them are specifically targeting the wireless constraints and low power requirements. In this paper, a piezoceramic transducer amplifier for wireless active SHM systems has been designed. Power requirements are met by two digital On/Off switches that set the amplifier in a standby state when not in use. It provides a stable ${\pm}180$ Volts output with a bandwidth of 7k Hz using a single 12 V battery. Additionally, both voltage and current outputs are provided for feedback control, impedance check, or actuator damage verification. Vibration control tests of an aluminum beam were conducted in the University of Houston lab, while wireless active SHM tests of a wind turbine blade were performed in the Harbin Institute of Technology wind tunnel. The results showed that the developed amplifier provided equivalent results to commercial solutions in suppressing structural vibrations, and that it allows researchers to perform active wireless SHM on moving objects with no power wires from the grid.

The Effects of Weight Training and Complex Training on Youth Soccer Player Performance

  • Dong Geun LEE;Hwang Woon MOON
    • Journal of Sport and Applied Science
    • /
    • 제7권4호
    • /
    • pp.13-18
    • /
    • 2023
  • Purpose: This study aims to determine what changes occur in body composition and performance by subjecting youth soccer players to weight training and combined training, which are known to be effective in improving anaerobic capacity, for 6 weeks. Research design, data, and methodology: This study was conducted on 30 high school soccer players from S City who had no current injuries or medical problems and had been registered as players with the Korea Football Association for more than 3 years. Subjects were divided into a weight training group (WTG, n=15) and a combined training group (CTG, n=15). Training lasted 6 weeks, and measurements were taken before and after training. Mean (M) and standard deviation (SD) were calculated to present the descriptive statistics of all dependent variables. Paired t-tests were used to test for within-group differences. Further, Independent t-tests were employed to test for between-group differences. Results: In terms of body composition, height significantly increased in WTG and CTG, and body fat percentage significantly decreased in CTG. As for performance, WTG's 20m sprint record decreased significantly. Conclusion: As a result, this study confirmed that weight training improved the 20m sprint ability of youth soccer players. Future research could provide more useful information by extending the study period and incorporating the physical characteristics of adolescents.

Effect of Silicone-modified Microsilica Content on Electrical and Mechanical Properties of Cycloaliphatic Epoxy/Microsilica System

  • Park, Jae-Jun;Yoon, Chan-Young;Lee, Jae-Young;Cheong, Jong-Hoon;Kang, Geun-Bae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.155-158
    • /
    • 2016
  • The effect of microsilica content modified with silicone-modified epoxy on electrical and mechanical properties of cycloaliphatic epoxy/microsilica system was investigated. The cycloaliphatic epoxy resin was diglycidyl 1,2-cyclohexanedicarboxylate and curing agent was an anhydride. Surface of microsilica was modified with silicone-modified epoxy. Electrical breakdown strength, the most important property for electrical insulation materials was tested. Tensile and flexural tests were also performed using universal testing machine (UTM). The microcomposite with 60 wt% microsilica shows maximum values in electrical breakdown strength.

Performance Evaluation of Location Estimation System Using a Non Fixed Single Receiver

  • Myagmar, Enkhzaya;Kwon, Soon-Ryang
    • International Journal of Contents
    • /
    • 제10권4호
    • /
    • pp.69-74
    • /
    • 2014
  • General location aware systems are only applied to indoor and outdoor environments using more than three transmitters to estimate a fixed object location. Those kinds of systems have environmental restrictions that require an already established infrastructure. To solve this problem, an Object Location Estimation (OLE) algorithm based on PTP (Point To Point) communication has been proposed. However, the problem with this method is that deduction of performance parameters is not enough and location estimation is very difficult because of unknown restriction conditions. From experimental tests in this research, we determined that the performance parameters for restriction conditions are a maximum transmission distance of CSS communication and an optimum moving distance interval between personal locations. In this paper, a system applied OLE algorithm based on PTP communication is implemented using a CSS (Chirp Spread Spectrum) communication module. A maximum transmission distance for CSS communication and an optimum moving distance interval between personal locations are then deducted and studied to estimate a fixed object location for generalization.

안전한 캠핑 문화의 정착을 위한 야외용 프로판 연소기 안전기준 실증 연구 (A Verification Test on Safety Standards of Portable Propane Gas Stove for Safe Camping Culture)

  • 안현수;최슬기;이창언;김영구
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.293-294
    • /
    • 2014
  • In Korea, only butane gas could be used as fuel gas of the outdoor gas stove. However, butane is not vaporized well at low temperatures. For this reason, in the field, nozzle of the portable butane gas stove is converted illegally to use propane gas. Because vapor pressure of propane gas is higher than that of butane gas at same temperature, gas accidents such as gas leakage could be occurred. To prevent gas accidents and use portable propane gas stoves safely, international standards need to be analyzed and verification tests need to be performed with prototype stove. This study could suggest to revise standard for safety improvement with portable propane gas stoves.

  • PDF