• Title/Summary/Keyword: Outdoor insulator

Search Result 102, Processing Time 0.028 seconds

Improvement on Surface Properties of Engineering Plastic with Adding Micro-$Al_2O_3$, Nano-$Al(OH)_3$ (Micro-$Al_2O_3$와 Nano-$Al(OH)_3$ 첨가에 따른 엔지니어링 플라스틱의 표면특성 개선)

  • Jung, Eui-Hwan;Lee, Han-Ju;Lim, Kee-Joe;Heo, Jun;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.29-29
    • /
    • 2010
  • Surface contamination and leakage current have caused operating problems. A flashover in a substation may result in destruction of an insulator or many others electrical equipment. Engineering plastics have good characteristic (light weight, good productivity and little of void) as compare with epoxy or porcelain insulators. Outdoor insulator must have resistance to contamination. However, it isn't suited to outdoor insulator because it is not hydrophobic. RTV(Room temperature vulcanizing) has a good property of hydrophobic and micro-filler. nano-filler have characteristics of obstructing exothermic reaction. In order to reduce the incidence of insulator flashover and damage, the silicon rubber contained with micro, nano-filler coating on surface of engineering plastics. In this paper, it compares tracking resistance, leakage current of the engineering plastic coated RTV with that of non-coated engineering plastic. And filled-composites performed much better than non-filled composites.

  • PDF

Aging Evaluation of Polymer Insulator Housing with UV Exposure (자외선 노출에 따른 폴리머애자 하우징의 열화특성평가)

  • 이병성;한재홍;김찬영;한용희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.214-217
    • /
    • 1999
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in a outdoor environment is still very limited. Especially, these insulator are subjected to the environmental stress such as ultraviolet radiation. Hence, in this paper. the influence of UV radiation on the aging of the shed materials was evaluated. For the aging evaluation, these insulators studied by experiment methods such as contact angle measurement. oxidation induced time. SEM/EDX, FTRI-ATR, tracking test for the different insulator samples. With the increased UV exposure time, samples are shown to exhibit degradation comparable to those of new ones

  • PDF

Silicone Rubber as the Shed Material of Composite Insulator for Electric Power Distribution and Transmission (송배전용 COMPOSITE INSULATOR의 SHED 재질로서 실리콘 고무)

  • Kang, D.P.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1367-1369
    • /
    • 1994
  • Recently composite insulators have been In the spotlight because they have many good characteristics as a outdoor insulator for high voltage. The long term properties in composite insulator depend on shed materials. Silicone rubber out of some candidates of shed material has been obtaining good credit from the long term test in field.

  • PDF

Investigation on Flashover Development Mechanism of Polymeric Insulators by Time Frequency Analysis

  • Muniraj, C.;Krishnamoorthi, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1503-1511
    • /
    • 2013
  • This paper deals with the analysis of leakage current characteristics of silicone rubber insulator in order to develop a new condition monitoring tool to identify the flashover of outdoor insulators. In this work, laboratory based pollution performance tests are carried out on silicone rubber insulator under ac voltage at different pollution levels and relative humidity conditions with sodium chloride (NaCl) as a contaminant. Min-Norm spectral analysis is adopted to calculate the higher order harmonics and Signal Noise Ratio (SNR). Choi-Williams Distribution (CWD) function is employed to understand the time frequency characteristics of the leakage current signal. Reported results on silicone rubber insulators show that the flashover development process of outdoor polymer insulators could be identified from the higher order harmonics and signal noise ratio values of leakage current signals.

Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings (가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가)

  • Cho, H.G.;Kim, I.S.;Ahn, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF

An Estimation of Contamination Degree using the Statistical Analysis between Contamination and Climatic Data (오손도와 기상 데이터의 통계적 분석을 이용한 오손도 예측)

  • 심규일;김호수;김주한;박흥석;한상옥
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • The accumulation of salt contamination could be the source of electrical accident. The degree of contamination on outdoor insulator is represented by ESDD(equivalent salt deposit density). The salt is transported by the wind to the outdoor insulator and cleaned by the rain. So, we can estimate the relation between climatic data and ESDD by using the multiple regression method. The results of pre-study presented the high relation coefficient(0.874). But these results couldn't apply to another period So, this paper improves above problem by mathematical process of climatic data The main method is accumulation of passed climatic data and conversion of the rainfall by the wind. Then, we confirmed the increasement of relation coefficient(0.898).

Effects of Surface Charges on Hydrophobicity and Surface Potential Decay with Various Surface States of Silicone Rubber for Outdoor Insulator (옥외용 실리콘 절연재료의 발수성에 미치는 표면전하의 영향과 표면 상태에 따른 표면전위 감쇠)

  • 연복희;박충렬;허창수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.678-686
    • /
    • 2002
  • This paper presents the effects of accumulation of surface charges on hydrophobic level and the changes of surface potential decay with various artificial environment treatments on high temperature vulcanized (HTV) silicone rubber used for outdoor insulating material. For this study, the charging apparatus by corona discharge, in which grid electrode was installed between the main corona and ground electrode, was used. From this study, it was found that the accumulation of surface charges above a critical surface potential on silicone insulating materials could lead to the temporary loss of surface hydrophobicity. In addition, corona stress and water absorption stress increase the decay rate of surface charges of HTV silicone rubber, while ultraviolet (UV) stress causes longer decay time. We could conclude that the effects of surface charges on hydrophobicity level and the changes of surface state by various artificial treatments were found through a trend of surface potential decay.

The Estimation of Outdoor Insulation According to the Concentration of Surface Discharge (표면방전의 집중에 따른 옥외용 설비의 성능평가)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin;No, Jin-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.212-216
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

Electrical Properties of Outdoor Insulator with the Difference of Contaminated Condition (오손조건에 따른 옥외절연물의 전기적 특성)

  • 최남호;구경완;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.467-470
    • /
    • 2000
  • This paper present the result of the investigation, electric properties of outdoor insulators with the difference of contaminated condition. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. A mini-fog chamber with transparent acryl and the standard contamination solution with kaoline was used. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current and the ambient condition, such as relative humidity and temperature, a DAS system was developed with LabView. From the result, we could know the influence of contaminated condition. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

Comparison of the Poor Insulator Detecting Technique for the Reliability Enhancement of the Electric Power Facilities (전력설비의 신뢰성 향상을 위한 불량애자검출기법의 비교)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.417-423
    • /
    • 2008
  • For the evaluation in the safety of outdoor insulator, there are various methods such as: visual observation; voltage measurement; use of ultrasonic wave due to partial discharge; electric field measurement; use of infrared/ultraviolet sensor-type camera. However, many problems have been issued regrading the reliability of the evaluation test and safety of testing operation. Accordingly, the present study has investigated and analyzed the characteristics and mechanisms of the insulator deterioration, in order to obtain an optimal method for detecting poor insulator so that the reliability of power facilities can be enhanced. Besides, based on theoretical analysis of domestic and international detection methods for poor insulator, the reliability has been compared and evaluated quantitatively. As a result, it was shown that the corona camera would be the best choice for domestic workplace application in detecting poor insulator for enhancing the reliability of power transmission line.