• Title/Summary/Keyword: Outdoor Noise

Search Result 197, Processing Time 0.051 seconds

Environmental Noise Prediction of Power Plants (발전소 환경소음 예측)

  • 조대승;유병호
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.621-629
    • /
    • 1997
  • For computer aided design and costruction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

Structural Vibration Characteristics for an Outdoor Units Support of an Air-conditioner (에어컨 실외기 받침대의 구조진동 특성)

  • Ryu, Bong-Jo;Song, Seon-Ho;Lim, Chae-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.215-217
    • /
    • 2008
  • This paper deals with the structural vibration characteristics for an outdoor units support of an air-conditioner. Even though main noise sources are compressor noise and fluid noise which is caused by the fan, the structural modification of the outdoor units support may affect vibration and noise. In this paper, damping ratios for two kinds of an outdoor units support of an air-conditioner are measured through the modal testing. In order to reduce the structural borne noise due to an outdoor units support of an air-conditioner, four kinds of rubber materials are selected and tested.

  • PDF

The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner (가정용 에어컨 실외기의 기동 소음 분석)

  • Son, Young-boo;Lee, Seung-mock;Ha, Jong-hun;Lee, Byeoung-chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

Environmental Noise Prediction of Power Plants (발전소 환경소음 예측)

  • 조대승;유병호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.452-459
    • /
    • 1997
  • For computer aided design and construction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

Prediction and analysis of noise level of outdoor areas in roadside apartment complexes (도로변 아파트 단지 옥외공간의 소음도 예측 및 분석)

  • Shin, Hye-Kyung;Yang, Hong-Seok;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.885-887
    • /
    • 2014
  • Outdoor spaces in an apartment complex have been enlarged by the increased underground car parking. It has become accepted as important place for acoustic comfort of resident. This paper attempts to determine the noise exposure to the outdoor area in 21 apartment complexes built within 5 years. The results showed that the average noise level of outdoor area ranged from 37.6dB(A) to 67.2dB(A). And the percentage of areas below the noise level of 55dB(A) range 0.1% to 95.0%. The analysis on correlations shows that the traffic volume and building coverage have significant effects on noise level.

  • PDF

Indoor And Outdoor Noise Distribution in Apartment House for Each Story (공동주택의 내.외부에 따른 층별 소음분포)

  • Park, Cheol-Yong;Hong, Goo-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.1-4
    • /
    • 2006
  • Most apartment houses were sited in road because it was convenient for transportation. One of the most noise is traffic noise at apartment house. The tested site was closely located in rail road and installed soundproofing wall. This study is measured indoor and outdoor noise distribution in apartment house for each story. It was similar noise distribution at indoor test but it was different noise distribution at outdoor test for each story. It was measured higher noise level at the upper stories than 5th story in outdoor noise distribution.

  • PDF

Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique (구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용)

  • 김규식;진심원;정인화;이정우;강연준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

A Study on Standards of Transformer Noise Level for Outdoor Substation (옥외 변전소 변압기의 소음레벨 기준에 대한 연구)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Kwak, Ju-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2213-2219
    • /
    • 2008
  • Customer complaints on noise from the power transformer have been increased because of their concerns on environment. In order to solve fundamental noise problem of the transformer, KEPCO and domestic transformer manufacturers are developing 55 dBA class low noise transformers. To check accordance of the noise abatement law, we study relation between transformer noise level and substation border noise level. We present 'noise level of the substation border' under operating conditions and transformer noise level change. We also present an appropriate noise level of the transformer that satisfy the noise abatement law for outdoor substations.

The Study on the Aeroacoustic Characteristics of an Axial Fan for an Air-Conditioner (공기조화기 축류팬의 공력소음 특성 연구)

  • Lee, Soo-Young;Han, Jae-Oh;Kim, Tae-Hun;Lee, Jai-Kwon;Jeon, Wan-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.205-208
    • /
    • 2006
  • This paper proposes a new computational aeroacoustics method for an axial fan analysis. The major aeroacoustic noise source of an outdoor air-conditioner is the axial fan. It was revealed that the dominant noise source is the aerodynamic interactions between the rotating blade and stationary orifice. Many researches were focused on the fan only case. However, it does not fit to a real outdoor unit of air-conditioner. Especially, the inlet part of the axial fan of real system case is complex and not uniform. So, in order to identify the dominant noise source of axial fan, full outdoor unit analysis is important. Transient CFD analysis of full system was performed by commercial CFD code - SC/Tetra. Dominant noise source of the system was calculated by commercial CFN code - FlowNoise. The results show that not only BPF peaks but also broadband noise are similar to the measured data.

  • PDF

Active Control for Outdoor Noise using an FXLMS Approach

  • Hou, Hai-Feng;Kim, Dong-Il;Lee, Young-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.672-672
    • /
    • 2011
  • This study describes the comparison of noise suppression performances at different locations of two error microphones in active noise control (ANC) for outdoor applications. For this study, 12 different locations were predefined to decide best locations for error sensors in terms of suppressing noise. As shown in Fig. 1, the ANC system with one primary loudspeaker, two secondary loudspeakers and two error microphones is operated by a filtered-x LMS (FXLMS) algorithm which is implemented in a TI 6713 DSP board and Realsys 4713 AD/DA Extension board. The noise for the primary source is a typical road noise measured at a highway roadside. The lengths of adaptive filters of W1 and W2 are varied from 32 to 128 respectively. An intensive computer simulation was accomplished before outdoor ANC experiments. It is expected from the simulation results that the ANC performances are very much dependent upon the locations of the two error microphones.

  • PDF