제재업의 생물학적인자 노출실태 평가 (Exposure Assessment for Airborne Biological Agents in Sawmills)

  • 박해동;박현희;이인섭
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.274-281
    • /
    • 2010
  • The objectives of this study are (a) to investigate the distribution patterns and exposure concentrations of biological agents in sawmill industries and (b) to compare sampling methods of biological agents. The representative processes of 5 sawmills were selected to measure total airborne bacteria, fungi, endotoxin as well as dust. Airborne bacteria and fungi were measured with one stage impactor, six stage impactor and gelatin filteration methods. Endotoxin was collected with polycarbonate filters and analysed by kinetic chromogenic Limulus Amebocyte Lysate method. Geometric mean levels of airborne bacteria, fungi, endotoxin and dust were 1,864 CFU/$m^3$, 2,252 CFU/$m^3$, 31.5 EU/$m^3$ and 2.4 mg/$m^3$. The ratios of indoor/outdoor concentrations were 3.7 for bacteria, 4.1 for fungi, 3.3 for endotoxin and 9.7 for dust. The respiratory fractions of bacteria were 68.0, 50.9, 49.2 and 45.1% in band-saw, table-saw, rip-saw process and outdoor air. The respiratory fractions of fungi were 78.7, 90.8, 87.5 and 84.8% in band-saw, table-saw, rip-saw process and outdoor air, respectively. There was no significant differences in bacterial concentrations among single stage, six stage impaction and filteration methods. But, fungal concentrations measured with filtration methods were significantly higher than those with impaction methods. Geometric mean levels of airborne bacteria and fungi were higher than the OSHA guideline values of 1,000 CFU/$m^3$. The respiratory fractions of fungi were above 75%. The concentrations of biological agents were significantly different among culture-based sampling methods. In the exposure assessments of biological agents, further studies are needed for the comparisons of diverse sampling methods and the investigations of environmental factors.

무수초산 및 포름알데하이드 기상처리 산벚나무의 야외폭로 및 촉진열화 (Weathering of Prunus sargentii Specimens Modified with Acetic Anhydride and Formaldehyde Vapor)

  • 강호양;김수원;박상진
    • Journal of the Korean Wood Science and Technology
    • /
    • 제31권5호
    • /
    • pp.57-64
    • /
    • 2003
  • 고목재의 치수안정성을 향상시키는 무수초산과 포름알데하이드 기상처리가 팔만대장경 경판의 주요 소재인 산벚나무의 중량, 흡습성, 그리고 재색에 미치는 효과를 야외폭로와 촉진열화시험을 통해 측정하였다. 무수초산과 포름알데하이드 72시간 기상처리에 의한 시편의 중량은 각각 평균 8.1과 15.7% 증가하였다. 두 달 이상 야외 폭로된 아세틸화 시편의 중량은 1.5% 밖에 감소하지 않았으나 포름알데하이드 시편은 매우 많이 감소하였다. 또 아세틸화 처리는 시편의 흡습성을 낮추었으며 자외선에 의한 갈변을 방지하였으나, 포름알데하이드 처리는 그렇지 못하였다. 한편 포름알데하이드 처리시간이 긴 시편일수록 할열과 변형이 더 많이 발생하였다. 따라서 포름알데하이드 처리는 고목재 보존방법으로 맞지 않으나, 아세틸화 기상처리는 액상처리와 같이 중량을 과도하게 증가시키지 않으면서도 자외선과 비로 인한 재색변화와 중량감소를 막아줌으로 고목재의 보존처리에 적합하다고 할 수 있다.

A Study on the Applicability of Corrosion Inhibitor for Outdoor Copper Alloy

  • Shin, Jeong Ah;Wi, Koang Chul
    • 보존과학회지
    • /
    • 제34권4호
    • /
    • pp.259-271
    • /
    • 2018
  • Outdoor copper alloy is exposed to the atmospheric environment, accelerating corrosion progress compared with indoor copper alloy. In order to prevent corrosion, the outdoor copper alloy is coated with wax to block external corrosion factors. However, corrosion of the inside of the coating film is highly likely to continue without the internal corrosion prevention treatment. B.T.A, which is used as a copper alloy water-soluble corrosion inhibitor, has a high possibility of being harmful to the human body and is mainly used to treat excavated artifacts. This study had selected the water-soluble corrosion inhibitor, which was easier to use than the existing wax and B.T.A being used in corrosion inhibition treatment for outdoor copper alloy. A comparative study was conducted on B.T.A, which is a water-soluble corrosion inhibitor used on excavated artifacts, and $VCI^{(R)}$, $Rus^{(R)}$, and L-cys, an amino acid corrosion inhibitor, used for tin bronze test pieces. The experimental method was conducted for a certain period of time with the salt, acid, and air pollution affecting the corrosion of outdoor copper alloy. Based on experiment results, it was concluded that the best water - soluble copper alloy corrosion inhibitor in the atmospheric environment is $VCI^{(R)}$. and it could be considered to be applied in replacement of B.T.A due to its low harmfulness. In addition, $VCI^{(R)}$ is judged to serve as a corrosion inhibitor for outdoor copper alloy because it showed the best result even in the outdoor exposure test which is a real atmospheric environment.

단기간 풍화가 단청도채된 소나무재의 방염성능에 미치는 영향 (Effect of Short-Term Weathering on Flame Retardant Performance of Korean Red Pine Wood Coated with Dancheong)

  • 손동원;홍종욱;박진호;이화수;정용재;한규성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.785-808
    • /
    • 2016
  • 단기간의 인공열화와 옥외폭로의 두 시험조건에 따라 나타나는 목조문화재용 방염제 성능 차이를 비교하여 인공열화시험에 대한 신뢰성을 평가하고자 하였다. 주사전자현미경 분석결과, 목재 표면에 방염제의 용융으로 인해 생성된 탄화물이 층을 형성함으로써 연소를 지연시키는 작용이 일어나는 것을 확인하였다. 2주간의 인공열화 및 6개월간의 옥외폭로 시험처리를 마친 방염처리 된 단청시편에 대해 열방출률(HRR) 및 총열방출량(THR)을 측정한 결과, 열화 전 후의 방염 성능의 변화가 거의 나타나지 않았다. 실험결과 6개월간의 옥외폭로 시편과 2주간의 인공열화(6개월의 옥외폭로에 해당한다고 추정한 조건) 시편에서 근사한 연소실험 결과 값을 얻을 수 있었다.

광양만권 공단지역 일부 지역 주민들의 VOCs 노출농도 및 건강위해성 평가 (Health Risk Assessment and VOCs Levels of Residents in Industrial Area)

  • 이치원;최수현;홍성철;정은경;정용택;양원호;이종대;손부순
    • 한국환경과학회지
    • /
    • 제20권11호
    • /
    • pp.1373-1382
    • /
    • 2011
  • This research had been conducted from May to October 2007, studying 110 residents of G, Y, H industrial area in Jun-nam province. It is designed to understand the difference in levels of indoor, outdoor and personal exposure to VOCs(benzene, toluene, Ethylbenzene) and a health risk assessment was conducted to see if there was any fatal cause from carcinogenic or non - carcinogenic elements from a case group and a control group in all areas as well as each different area. In the case of benzene in the air, the geometric levels for the case group are indoor, outdoor and personal exposure; a higher than for the control group. As a results of the Monte - Carlo study about benzene, it shows that the case group's carcinogenicity is higher than that of the control group and it also shows that, on the CTE, RME condition and Monte - Carlo analysis, all subjects are seen to exceed the carcinogenicity tolerance $10^{-6}$ of US EPA. In the case of toluene, ethylbenzene on the CTE, RME condition and Monte - Carlo analysis, these do not exceed the non - carcinogenic standard of 1, but toluene in RME condition for both groups' personal exposure and the indoor and personal exposure of ethylbenzene in Monte - Carlo show that these seem to exceed the standard.

주택특성에 관련된 실내 이산화질소 농도에 관한 연구 (A Study on Concentration of Indoor Nitrogen Dioxide in Relation to House Characteristics)

  • 양원호;배현주;김현용;정문식;정문호
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.85-92
    • /
    • 1999
  • Indoor air quality tends to be the dominant contributor to personal exposure because most people spend over 90% of their time indoors. For some contaminants, exposure to indoor air poses a potentially greater health threat than outdoor air exposures. Indoor nitrogen dioxide ($NO_2$) levels are mainly affected gas range, flue gas spillage, kerosene heaters, wood-burning appliances and cigarette smoke. In addition, indoor $NO_2$ levels are influenced by such house characterization as surface reaction and air exchange rate. In this study, the measurements of indoor and outdoor $NO_2$ concentrations were taken using identical protocols, and information was collected on housing characteristics using identical questionnaires in 14 houses out of 15 houses for daily 30 daily 30 days in Brisbane, Australia.The usage of gas range was the most contributing factor in indoor $NO_2$ concentration in relation to house characteristics. Average indoor and outdoor ratios of NO2 concentration in electronic and gas cooking houses were $0.6{\pm}0.1$ and $0.9{\pm}0.2$, respectively. The frequency distributions of $NO_2$ concentration in each house were approximately log-normal Geometric mean of indoor $NO_2$ concentrations of electronic and gas cooking houses for daily 30 days ranged from 2.5 ppm to 11.5 ppm with a mean 6.8 and from 4.7 ppm to 28.6 ppm with a mean 15.6 ppm, respectively. The $NO_2$ concentrations between electronic and gas cooking houses were significantly different (p<0.05). Since each house has different life-style and house characteristics, sampling interval to measure the $NO_2$ levels was recommended above 7 days.

  • PDF

VOCs Concentrations of Indoor and Outdoor in Solvent Thinner-Using Occupation, and Application of TiO$_2$ Photocatalytic Air Cleaner

  • Wonho Yang;Joon Cho;Busoon Son;Park, Jongan
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.1.1-2
    • /
    • 2002
  • Ultimate objective of industrial hygiene is the prevention of health impairment that may result from exposure to chemicals at workplaces. This implies the definition of permissible levels of exposure, that is, levels that according to the present status of knowledge are estimated to cause no adverse health effects during the lifetime of the workers, and the regular assessment of the possible health risk associated with exposure by comparing the current or the integrated exposure with the permissible exposure limits. Workers in solvent thinner-using occupation environment might be highly exposed to VOCs(volatile organic compounds) because solvent thinner has been used extensively such as painting, spraying, degreasing, coating and so on in Korea. The purpose of this study was to recognize, evaluate and propose the alternative control the VOCs from solvent thinner-using workplace.

  • PDF

외기온 -15℃에 노출시간 변화가 콘크리트의 초기동해 피해에 미치는 영향 (Outside -15℃ Exposure Time Impact on Early Frost Damage)

  • 최윤호;이영준;이동주;경영혁;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.85-86
    • /
    • 2019
  • In this study, when the normal concrete became a $20^{\circ}C$ image after the exposure time at an external temperature of $-15^{\circ}C$, the limit point of the early frost damage was analyzed. As a result, it was confirmed that the degree of concretion was higher than the external level after carrying in and after exposure, and that the initial Tokai damage was observed after 12 hours of exposure.

  • PDF

제철소 근로자의 벤젠/톨루엔/크실렌 국소환경 측정을 이용한 총 노출 예측 (Estimation of Total Exposure to Benzene, Toluene and Xylene by Microenvironmental Measurements for Iron Mill Workers)

  • 김영희;양원호;손부순
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.359-364
    • /
    • 2007
  • The aim of this study were to assess the personal exposure to volatile organic compounds (VOCs) and to estimate the personal exposure using time-weighted average model. Three target VOCs (benzene, toluene, xylene) were analyzed in personal exposure samples and residential indoor, residential outdoor and workplace indoor microenvironments samples in the iron mill 30 workers during working 5 days. Personal exposure to VOCs significantly correlated with workplace concentration p<0.05), suggesting workplace had strong source and major contribution to personal exposure. Personal exposure could be estimated with time activity pattern and time weighted average (TWA) model of residential indoor and workplace concentrations measured. Time weighted mean microenvironments concentrations were close approximately of personal exposure concentrations. Total exposure for participants can be estimated by TWA with microenvironments measurements and time activity pattern.

옥외 전기시설물 침수시 누설전류에 의한 인체영향 (Human Hazard by Outdoor Electrical Facilities in Submerged Area)

  • 하태현;이현구;배정효;김대경
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.