• Title/Summary/Keyword: Outdoor Exposure

Search Result 308, Processing Time 0.022 seconds

Exposure Assessment of volatile Organic Matters (VOCs) Using Exposure Biomarker in the Residents Living Near Petrochemical Industry Areas (공단지역 주민에서 휘발성 유기오염물질의 호흡기 노출에 대한 생체지표 평가)

  • 신동천;박성은;임영욱;양지연;김명수
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.3
    • /
    • pp.81-91
    • /
    • 2000
  • Residents who live near petrochemical industrial areas are exposed to a variety of petrochemicals, including benzene or benzene-containing liquids. It is a serious concern because some VOCs are carcinogens naturally present in petroleum and gasoline. The aim of this study was to assess the exposure to VOCs, measured by personal/indoor/outdoor air sampling, and to estimate the relationship between the air samples and biological monitoring data. Through biological monitoring, we investigated VOCs in blood and s-phenylmercapturic acid (s-PMA) , minor urinary metabolites of benzene. The external benzene exposure of subjects was measured using passive dosimeters and urinary s-PMA and blood-benzene were determined by GC/MS. More than 80% of subjects were detected for m-xylene, ethylbenzene, and toluene in blood samples and not detected at all for chloroform, 1 , 1 , 1 -trichloroethylene, and tetrachloroethylene. The mean concentration of benzene in the breathing zone of residents was 6.3 $\mu\textrm{g}$/m$^3$, personal, indoor and outdoor concentrations were strongly correlated to each other. s-PMA detected in all subject samples was affected by personal exposure (p< 0.05) and the level was different by age (p< 0.01). Blood benzene was not affected by external benzene during these periods .

  • PDF

A study on the Evaluation of Surface Properties of UHPC Panels following long-term outdoor exposure (옥외 장기폭로에 따른 UHPC 패널의 표면 특성 평가 연구)

  • Kim, Tae-Ik;Choi, Byung-Keol;Park, Yong-Kyu;Choi, Sang-Hoon;Yoon, Gi-Won;Lee, Dae-Seek
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.176-177
    • /
    • 2022
  • In this study, surface performance evaluation was conducted according to the fiber and surface finishing technique of the exterior material using Ultra High Performance Concrete(UHPC), whitch is spotlighted as a highly durable exterior material. As a result of outdoor exposure, the initial performance of the UHPC Panel using organic fibers was maintained without being affected by the surface finishing technique. In the specimen using steel fiber, the surface performance was maintained when the water repellent treatment was performed in the plain specimen, but fiber corrosion occurred in the specimen to which the surface finishing technique was applied.

  • PDF

Association Between Occupational Physicochemical Exposures and Headache/Eyestrain Symptoms Among Korean Indoor/Outdoor Construction Workers

  • Jung, Sung Won;Lee, June-Hee;Lee, Kyung-Jae;Kim, Hyoung-Ryoul
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.437-444
    • /
    • 2019
  • Background: Headache/eyestrain symptoms are common health problems that people experience in daily life. Various studies have examined risk factors contributing to headache/eyestrains, and physicochemical exposure was found to be a leading risk factor in causing such symptoms. The purpose of this study was to examine the relationship of headache/eyestrain symptoms with physicochemical exposure among Korean construction workers depended on worksite. Methods: This study used data from the 4th Korean Workers Conditions Survey and selected 1,945 Korean construction workers as participants. Multivariable logistic regression analysis was used to determine the relationship. Results: Exposure to vibrations among all construction workers affected the moderate exposure group [odds ratio (OR) 1.53, 95% confidence interval (CI) 1.01-2.32], the high exposure group (OR 1.77 95%CI 1.17-2.67), and the indoor high exposure group (OR 1.61, 95%CI 1.02-2.55) and among outdoor construction workers, the moderate group (OR 6.61, 95%CI 15.4-28.48) and the high group (OR 6.61, 95%CI 1.56-27.98). When exposed to mist, dust, and fumes, the indoor high exposure group was significantly affected (OR 1.63, 95%CI 1.07-2.47). All construction workers exposed to organic solvents were affected, high exposure group (OR 1.69, 95%CI 1.15-2.49) and indoor high exposure group (OR 1.77, 95%CI 1.08-2.89). The high exposure group in all construction worker (OR 1.70, 95%CI 1.20-2.42) and the indoor high exposure group (OR 1.83, 95%CI 1.17-2.89) also were affected by secondhand smoking exposure. Conclusion: Many physicochemical exposure factors affect headache/eyestrain symptoms among construction workers, especially indoor construction workers, suggesting a deficiency in occupational hygiene and health environments at indoor construction worksites.

Accelerated and Outdoor Exposure Tests of Aluminum Coated Steel Sheets

  • Kim, Jongmin;Lee, Jaemin;Lim, Sangkyu;Jung, Choonho
    • Corrosion Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.199-204
    • /
    • 2011
  • Hot dip metallic coated steels like as galvanized (GI), zinc-aluminium (GL) and aluminium coated steels are mostly used where corrosion resistance is needed. There are two kinds (type 1 and type 2) of aluminium coated steel being commercially used among them. Type 1 aluminium coated steel is coated with an Al-5~11 wt%Si alloy and Type 2 aluminium coated steel consists of commercially pure aluminium. Type 1 Al coated steel is generally used in automotive components and electrical appliances while type 2 aluminium coated steel is mainly used in construction applications such as building cladding panels, air conditioning and ventilation system. In this study, Type 1 aluminium coated steels have tested by accelerated conditions (salt spray or corrosive gas) and outdoor exposure condition in order to understand their corrosion behaviour. Due to the distinct corrosion mechanism of Al which exposes to the severe chloric condition, Salt Spray Test cannot predict the ordinary atmospheric corrosion of Al based coated materials. In addition, the test results and their corrosion feature of Al coated steel sheets will be discussed comparing with other metallic coated steel sheets of GI and GL.

Atmospheric Corrosion Behavior of Carbon Steel by the Outdoor Exposure Test for 10 Years in Korea

  • Yoo, Y.R.;Choi, S.H.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.184-199
    • /
    • 2022
  • Steel was exposed in an atmospheric environment, and atmospheric environmental factors that include chloride, humidity, SO2, NO2 etc. induced the corrosion of steel. Corrosivity categories classified by SO2 and chloride deposition rate were low, but those classified by TOW were high in the Korean Peninsula, and on these environmental categories, the corrosivity of atmospheres classified by corrosion rate in carbon steel was low medium, C2-C3, and medium, C3 for zinc, copper, and aluminum. This work performed the outdoor exposure test for 10 years at 14 areas in Korea and calculated the atmospheric corrosion rate of carbon steel. The atmospheric corrosion behavior of carbon steel is discussed based on the various corrosion factors. When the corrosion product forms on carbon steel by atmospheric corrosion, cracks may also be formed, and through these cracks, the environmental factors can penetrate into the interior of the product, detach some of the corrosion products and finally corrode locally. Thus, the maximum corrosion rate was about 7.3 times greater than the average corrosion rate. The color difference and glossiness of carbon steel by the 10 year-outdoor exposure tests are discussed based on the corrosion rate and the environmental factors.

Human Risk Assessment of Perchloroethylene Considering Multi-media Exposure (다매체 노출을 고려한 Perchloroethylene의 인체위해성평가연구)

  • Seo, Jungkwan;Kim, Taksoo;Jo, Areum;Kim, Pilje;Choi, Kyunghee
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.5
    • /
    • pp.397-406
    • /
    • 2014
  • Objectives: Perchloroethylene (PCE) is a volatile chemical widely used as a solvent in the dry-cleaning and textile processing industries. It was evaluated as Group 2 "probably carcinogenic to humans" by the Integrated Risk Information System (IRIS) of the United State Environmental Protection Agency (U.S. EPA) in 2012. In order to provide a scientific basis for establishing risk management measures for chemicals on the national priority substances list, aggregate risk assessment was conducted for PCE, included in the top-10 substances. Methods: We conducted the investigation and monitoring of PCE exposure (e.g., exposure scenario, detection levels, and exposure factors, etc.) and assessed its multi-media (e.g., outdoor air, indoor air, and ground water) exposure risk with a deterministic and probabilistic approach. Results: In human risk assessment (HRA), the level of human exposure was higher in the younger age group. The exposure level through inhalation at home was the highest among the exposure routes. Outdoor air or uptake of drinking water represented less than 1% of total contributions to PCE exposure. These findings suggested that the level of risk was negligible since the Hazard Index (HI) induced by HRA was below one among all age groups, with a maximum HI value of 0.17 when reasonable maximum exposure was applied. Conclusion: In conclusion, it was suggested that despite low exposure risk, further studies are needed considering main sources, including occupational exposure.

Aging Evaluation of Polymer Insulator Housing with UV Exposure (자외선 노출에 따른 폴리머애자 하우징의 열화특성평가)

  • 이병성;한재홍;김찬영;한용희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.214-217
    • /
    • 1999
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in a outdoor environment is still very limited. Especially, these insulator are subjected to the environmental stress such as ultraviolet radiation. Hence, in this paper. the influence of UV radiation on the aging of the shed materials was evaluated. For the aging evaluation, these insulators studied by experiment methods such as contact angle measurement. oxidation induced time. SEM/EDX, FTRI-ATR, tracking test for the different insulator samples. With the increased UV exposure time, samples are shown to exhibit degradation comparable to those of new ones

  • PDF

Methyl-Tertiary Butyl Ether(MTBE) and BTEX Inside and Outside Apartments with Different Construction Age

  • Jo, Wan-Kuen;Lee, Jong-Hyo
    • Journal of Environmental Science International
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Only limited information is available on the measured exposure levels of residents according to the construction age of apartments. As such, present study was conducted to measure and to compare the bedroom, living-room, and outdoor air levels of MTBE and benzene, toluene, ethyl benzene and m,p-xylene(BTEX) in both newer and older apartments. For both newer and older apartments, all the compounds except for MTBE showed significantly higher levels in bedrooms or living-rooms as compared to the outdoor concentrations. The ratio of bedroom or living-room median concentration to outdoor concentration was close to 1 for MTBE, whereas it was larger than 1 for other target compounds. It was also found that the bedroom and living-room appeared to have similar indoor sources and sinks for BTEX, but not for MTBE. The median concentration ratios of the newer apartments to the older apartments ranged from 1.63 to 1.81, depending upon the compounds. In contrast, the MTBE concentrations did not differ significantly between the newer and older apartments, thereby suggesting that although newer buildings could emit more VOCs, this is not applicable to all VOCs. Conclusively, the findings of present study should be considered, when designing exposure studies associated with VOC emissions in buildings and/or managing indoor air quality according to construction age of buildings.

Scenario Analysis of Personal Nitrogen Dioxide Exposure with Monte Carlo Simulation on Subway Station Workers in Seoul (확률론적 모의실험 기법을 이용한 일부 지하철 근무자들의 이산화질소 개인노출 시나리오 분석)

  • 손부순;장봉기;양원호
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 2001
  • The personal exposures of nitrogen dioxide(NO$_2$), microenvironmental levels and daily time activity patterns on Seoul subway station workers were measured from February 10 to March 12, 1999. Personal NO$_2$exposure for 24 hours were 29.40$\pm$9.75 ppb. NO$_2$level of occupational environment were 27.87$\pm$7.15 ppb in office, 33.60$\pm$8.64 ppb in platform and 50.13$\pm$13.04 ppb in outdoor. Personal exposure time of subway station workers was constituted as survey results with $7.94\pm$3.00 hours in office, $2.82\pm$1.63 hours in platform and 1 hours in outdoor. With above results, personal $NO_2$exposure distributions on subway station workers in Seoul were estimated with Monte Carlo simulation which uses statistical probabilistic theory on various exposure scenario testing. Some of distributions which did not have any formal patterns were assumed as custom distribution type. Estimated personal occupational $NO_2$exposure using time weighted average (TWA) model was 31.$29\pm$5.57 ppb, which were under Annual Ambient Standard (50ppb) of Korea. Though arithmetic means of measured personal $NO_2$exposure was lower than that of occupational $NO_2$exposure estimated by TWA model, considering probability distribution type simulated, probability distribution of measured personal $NO_2$exposures for 24 hours was over ambient standard with 3.23%, which was higher than those of occupational exposure(0.02%). Further research is needed for reducing these 24 hour $NO_2$personal excess exposures besides occupational exposure on subway station workers in Seoul.

  • PDF

Properties of Water Permeability and Porosity of Cement Mortar Substrate Coated with Siliceous Slurry Coating under Exposure Enviorment (폭로환경하에서 규산질미분말혼합 시멘트계 도포방수재가 바탕모르터의 투수성과 세공구조에 미치는 영향)

  • 김형무;오상근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.175-182
    • /
    • 1996
  • This paper deals with the properties of water permeability and porosity of cement mortar substrate coated with siliceous slurry coating under the exposure environment. Conditions of exposure enviornment are four kinds of in constant temperature water and humidity box, in indoor and outdoor exposure. Coated mortar substrate was expected continually increase in water and humidity condition, but was not in dry condition. Watertightness effect of siliceous coating was better in the condition of humidity then the dry condition, and the pore volume was decreased in that condition.

  • PDF