천장의 기하학적 형태에 따른 광선반 성능평가 시뮬레이션 연구 (Simulation Study on the Performance Evaluation of Light-shelf According to Geometric Shape of Ceiling)

  • 이행우;김용성;서장후;김덕수
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.181-192
    • /
    • 2014
  • Light-shelf is one of the most efficient natural lighting systems due to the improved function of the inflow level of the outdoor natural light. However, the existing research on the light shelf limits to the rectangular parallelepiped space, so do not provide sufficient data for various shapes of spaces. Thus, this study aims at deriving proper plan and relationship of the light shelf through its performance assessment depending on the indoor space shapes and utilizing them as basic data of light shelf design. The conclusions are as follows : 1) for 6m space depth, standard intensity of illumination satisfaction depth has shown 8.3%~26.3% improvement through the adjustment of the angle and width when installing light shelf compared to no light shelf installation; 2) $-30^{\circ}$, $-20^{\circ}$ and $-10^{\circ}$ light shelves set by this study play only as a blind regardless of the shape of ceiling on the summer solstice, and it is unsuitable; and 3) this study has derived proper plan of light shelf upon space shapes based on energy reduction and indoor evenness. The study results provide expanded data of the performance assessment of the light shelves according to the different space shapes and light shelf factors, which serves as a basis of the light shelves designing.

재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구 (A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions)

  • 이장일;홍석민;변재기;최영돈;이대영
    • 대한기계학회논문집B
    • /
    • 제38권5호
    • /
    • pp.413-421
    • /
    • 2014
  • 제습 냉방시스템은 증발식 냉각기를 이용하여 공조 공기를 냉각하는 시스템으로 전기구동 냉각기 없이 열에너지만으로 냉방 공급을 수행할 수 있다. 따라서, CFC 계열의 냉매 사용에 의한 오존층 파괴 및 하절기 냉각기 가동에 의한 첨두 전력부하의 증가 등 기존의 냉방시스템이 야기하는 여러 가지 문제점들을 해결할 수 있다. 본 연구에서는 제습 냉방시스템의 효율을 향상시키기 위해 냉방 성능과 엑서지 해석을 수행하였다. 특히 열역학 제2법칙에 근거한 엑서지 해석을 이용할 경우 전체시스템과 구성요소에서의 엑서지 파괴의 원인을 분석함으로써 시스템의 효율과 관련된 주제에 대하여 더욱 본질적인 측면에서 접근할 수 있다. 본 연구의 목적은 재생온도와 외기조건의 변화에 따른 재생 증발식 냉각기를 이용한 제습 냉방시스템의 성능계수, 냉방용량, 엑서지 성능을 평가하는 것이다.

액체식 PVT 복합모듈의 유형별 성능 비교 분석 (The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules)

  • 김진희;강준구;김준태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.792-797
    • /
    • 2009
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.

  • PDF

혼합냉매 (R290/R32) 적용 소프트 아이스크림 제조기 (drop-in 시험) (Soft ice-cream maker operating with mixed refrigerant R290/R32)

  • 박태균;한성필;이응렬;김내현;박형채
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.410-413
    • /
    • 2005
  • Drop-in tests were conducted using R290/R32 (31:69) mixture in an ice-cream maker for possible replacement of R-502 and R-404A. Optimum refrigerant charge and TEV opening were obtained through a series of experiments. At the standard outdoor condition ($35^{\circ}C$ DT, $24^{\circ}C$ WT), the time required for initial ice-cream making was 6'22", which was approximately the same as that of R-404A. The electric energy consumed was 660 kJ, which was about 10% higher than that of R-404A. The compressor outlet temperature ($8^{\circ}C$) and pressure (2.52 MPa) were higher than those ($60^{\circ}C$ and 1.48 MPa) of R-404A. The reason could be the usage of the same R-404A compressor although the specific volume of R290/R32 is much larger.

  • PDF

실험계획법에 의한 수직샤프트 제어인자 도출을 위한 상관관계 분석 (Correlation Analysis for deriving Control Parameters in Vertical Shafts by Design of Experiments)

  • 한화택;신철용;백창인
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.895-900
    • /
    • 2008
  • It is the objective of the present study to conduct correlation analysis for deriving control parameters in vertical shafts using the results obtain by the design of experiments in the preceding research. The control parameters are categorized into objective parameters, derived parameters, condition parameters, operation parameters, and sensing parameters. The maximum pressure in the shaft should be sufficiently small in order to maintain exhaust hood performance. The pressure variations between floors should also be minimized in order to maintain uniform exhaust performance between floors and to save energy for excessive pressure drop in the shaft. The standard deviation based on -4Pa is proposed as an objective parameter to control pressure in shafts. The correlation equation has been obtained between the standard deviation and the sensing parameters of outdoor temperature and the pressure at the top of the shaft.

  • PDF

통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향 (The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.100-108
    • /
    • 2012
  • 통풍과 차양이 하절기 옥외공간에서 인간이 느끼는 온열쾌적성에 어떤 영향을 미치는지를 객관적으로 검증하기 위하여 통풍과 차양을 달리한 실험구를 조성하고 흑구온도와 기온 및 풍속을 측정하여 평균복사온도를 환산하여 비교 분석하였다. 미기후 측정을 위하여 개방된 잔디밭에 철제 각관을 이용하여 가로${\times}$세로${\times}$높이가 각각 $3m{\times}3m{\times}1.5m$인 프레임을 구성하고, 투명 폴리에틸렌 필름과 농업용 차광막을 이용하여 통풍과 차양의 조건을 달리한 네 가지의 실험구를 조성하였다. 각 실험구 내 중심부 지면으로부터 1.2m 높이에서 베인형 풍속계와 흑구, 측온저항체(PT-100)를 이용하여 2011년 5월 1일부터 동년 9월 30일까지 풍속과 기온, 흑구온도를 매 분 단위로 계측하였다. 기상조건과 계측자료의 유효성 등을 고려하여 총 44일 동안의 13,262건의 자료를 바탕으로 실험구별 일중 시계열적 변화를 분석하였으며, 낮 시간에 해당되는 오전 7시부터 오후 8시까지의 7,172건의 자료를 바탕으로 실험구에 따른 통계적 차이를 해석하였다. 아울러 햇볕이 가장 강렬한 시간대인 오전 11시부터 오후 4시까지의 자료를 바탕으로 평균복사온도와 풍속 및 일사량과의 관계를 분석하였다. 평균복사온도를 기준으로 해석했을 때, 통풍이 차단된 노지에서의 측정기간 중 최고값이 $58.84^{\circ}C$까지 상승한 반면, 차양이 적용되고 통풍이 원할한 실험구의 최고값은 $42.94^{\circ}C$였다. 시험결과를 종합하면, 하절기 옥외공간에서 낮 동안의 평균복사온도에 있어서 차양에 의해서는 최대 $13^{\circ}C$, 평균 $9^{\circ}C$의 냉각효과가 발생한 반면, 방풍에 의해서는 반대로 평균 약 $3^{\circ}C$의 가열효과가 있는 것으로 정리되어, 통풍이 되지 않는 태양직사광 지역은 바람이 원활하게 통하는 그림자 지역 보다 최대 $16^{\circ}C$까지 높은 것으로 나타났다. 결론적으로 본 연구를 통해서 하절기 옥외공간의 열쾌적성을 개선하는데 차양이 가장 중요하며, 그 다음이 통풍이라는 사실을 파악할 수 있었다. 따라서 옥외공간에 더 많은 녹음수와 숲을 조성하여 그림자 지역을 증가시킴으로써 인간의 하절기 옥외활동에 많은 제약을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 미기후를 효과적으로 조성할 수 있으며, 나아가 정교하게 조성된 바람길이나 통풍 시스템을 적용한다면 도시 전체의 열환경도 효과적으로 개선할 수 있을 것이다.