• Title/Summary/Keyword: Outdoor(rooftop)

Search Result 22, Processing Time 0.027 seconds

The Effect of Impermeable Surface and Rainwater Infiltration Facilities on the Runoff pH of Housing Complexes (빗물 유출면 및 빗물 침투시설이 주거단지 유출빗물의 pH에 미치는 영향)

  • Hyun, Kyoung-Hak;Choi, Joung-Joo;Choung, Youn-Kyoo
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.39-47
    • /
    • 2010
  • In order to examine the effect of impermeable surface (rooftop, outdoor parking lot) and rainwater infiltration facilities on runoff pH, pH was measured. pH measurement spots were splash blocks accepted roof runoff of 3 sites, infiltration boxes and trenches accepted parking lot runoff and plastic rainwater harvesting facility accepted roof runoff. These measurements were operated at 3 housing complexes from 2006 to 2009. The rainwater runoff pH was influenced by the quality of the runoff surface material (concrete), the age of the building, waterproofing methods according to each housing site, antecedent rainfall conditions and others. Rain garden, infiltration boxes and trenches decreased the alkalinity of runoff by detention and infiltrating the roof and outdoor parking lot runoff. These results mean that decentralized rainwater management facilities of housing complexes can reduce effect on the outskirt aquatic ecosystem by the accumulation of substances causing pH rising in the infiltration facilities and rain garden.

A Study on Thermal Comfortable Following the Thermal Environment Migration in Detached Housing Area (열환경 완화를 통한 주택지내 쾌적성 확보에 관한 연구)

  • Ryu, Ji-Won;Jung, Eung-Ho;Hoyano, Akira;Kim, Dae-Wuk
    • Journal of the Korean housing association
    • /
    • v.24 no.1
    • /
    • pp.51-59
    • /
    • 2013
  • This study aims to improve the thermal comfort level of detached housing area by reducing the impact of thermal environment. The study focused on reducing surface temperature that is generated in buildings and adjacent spaces as a result of sensible heat load and presented a proposal on implementing planting method considering its outdoor condition and structure and composed materials. To perform the study, we utilized 3D-CAD to examine the outdoor condition and structure and composed materials that impact on surface temperature and conducted space design after reflecting climatic elements in simulations. The result is as follows. In reviewing temperature distribution of Heat Island Potential (HIP) of buildings and adjacent spaces, in case where green coverage ratio is increased, there was a $6^{\circ}C$ temperature difference and in regard to changes in the thermal environment in detached housing area, in case where rooftop planting, surface improvement, planting, and overall green coverage ratio is increased, there was a $10^{\circ}C$ temperature difference. In addition, there was difference in temperature in detached housing area following the changes in wind.

A Study on Spatial Characteristics of Indoor Rest Zones in the Campus Buildings (대학 캠퍼스 건물 내부휴게공간의 공간적 특성에 관한 연구)

  • Park, Joon-Soo;Kim, Sung-Ah;Suh, Ki-Young;Park, Chang-Hui;Yi, Seong-Chang
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.10 no.3
    • /
    • pp.37-43
    • /
    • 2003
  • This study investigates the physical characteristics of indoor rest zones using the Space Syntax Method. A conceptual framework is based on analysis of design works presented in competitions(544 rest zones of 24 buildings on 7 campuses). The analysis on the unit type of rest zones showed that they were mostly available as open type, followed by semi-open type and outdoor rest places. On the other hand, by classifying the shape of whole building into traffic lines and nodal points, it was found that the buildings with 3 or more traffic lines have lower availability than others, because the buildings required more nodal points along a little higher complexity and zoning formed at increased nodal points between building masses. The analysis on the location of rest zones on traffic lines showed that hall type was most excellent in the level of availability. Finally, the analysis on the floor height showed that hall-like open rest places and outdoor places like rooftop garden functioned as a factor to enhance the integration of different spaces. In conclusion, this research will help the follow-up studies make spatial creation planning that may enhance the spatial efficiency and availability of Indoor rest zones on the campus.

Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses (초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가)

  • Kim, Young-Bae;Kim, Jae-Hong;Sung, Jae-Yong;Lee, Myeong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof (쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과)

  • Song, Bong-Geun;Kim, Gyeong-Ah;Park, Kyung-Hun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

A Study on the Evaluation of Tensile Performance According to Pareral Jointing Methods of the Sheet Membrane Waterproofing System (방수시트의 평행접합방법에 따른 인장성능 평가연구)

  • Lee Jeoung-Yun;Oh Mi-Hyun;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.39-44
    • /
    • 2004
  • A heat and room temperature construction method of asphalt have been mainly applying to rooftop waterproofing in concrete structure, and the rest construction method are sheet, membrane and mortar waterproofing construction method. In particular, joint method in sheet waterproof method is as overlap joint which on being reinforced with fiber and tape, have been applying for job site to mechanical fix using protection disk and anchorage and metal ironwork on the end of sheet. These construction method cause cutting off joint of sheet as behavior of structure according to repairs of sheet itself and thermal conduct, outdoor air environment. In conclusion, we analyzed and examined the application of various sheets and piece ashes about superior 'I' joint which divide from one and the other sheet and progressed about joint construction method of fixing method for overlap.

  • PDF

An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101 (NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석)

  • Cho, Ji-Eun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • The study analyzes the appropriate number of people per a household by applying an evacuation simulation to a 27-floor apartment in accordance with the NFPA 101 standard. The results of the analysis are as follows. First, if there are three people residing in each household, there would be 156 households in total, of which 85.25% were evacuated within 5 minutes. Second, 208 households with 4 residents were evacuated within 5 minutes. Third, if there are five people residing in each household, there would be a total of 260 households and 71.92% of residents were evacuated within 5 minutes. Lastly, 62.82% of the 312 households, each consisting of 6 people, were evacuated within 5 minutes. Measures to reduce evacuation time include determining the width of the stairs according to the number of people indoors, the number of floors in the building, the slope of stairs, and the users' characteristics, the design reflecting the ventilation conditions of the stairs, the installment of outdoor evacuation stairs, two-way stairs, evacuation lift, and the installation of an evacuation safety zone for people to evacuate outside of the building in the middle floors. In addition, measures, such as the mandatory installation of automatic emergency door open-close device to the rooftop, are required to facilitate rooftop evacuation.

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position (태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가)

  • Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

Survey of Airborne Fungi Levels in 24 Seasonal Divisions and Correlation Analysis with Meteorological Elements (24절기 야외 부유곰팡이 농도 조사 및 기상요소와의 상관성 분석)

  • Kim, Myoung Nam;Hong, Jin Young;Lee, Jeong Min;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.35 no.6
    • /
    • pp.652-663
    • /
    • 2019
  • To identify daily and annual changes in outdoor airborne fungi, it is necessary to shorten the collection cycle and increase the number of measurements. In this study, measurements were performed by employing an air sampler and potato dextrose agar media on the rooftop of National Research Institute of Cultural Heritage during a period of one year (August 2018 to July 2019). The collection cycle spanned the twenty-four seasonal divisions and the collection time was 2 p.m. and 11 p.m.. Meteorological elements were collected at intervals of one hour. Furthermore, the concentration of airborne fungi was monitored and correlation analysis with meteorological elements was subsequently conducted. Obtained results indicate that the concentration of airborne fungi is found to be highest in November, autumn, night, followed by autumn, summer, winter, and spring. The concentration, type, and dominant species of airborne fungi can vary depending on factors such as rainfall, typhoons, and yellow dust (fine dust). The concentration of airborne fungi indicates a strong positive linear relationship between precipitation, number of precipitation days, and relative humidity. The concentration of airborne fungi was related to the period of increase of dead plants in terms of nutrition source, and to the high relative humidity conditions including rainfall in terms of meteorological elements.

Landscape Design of Gamcheon Wholesale Fish Market (감천항 수산물 도매시장 조경설계)

  • 권영휴;민권식;황용득
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.2
    • /
    • pp.70-78
    • /
    • 2002
  • The landscape disign of Gamcheon wholesale fish Market was designed around a turnkey base to promote the economy of Busan Metropolitan City, to establish a fishery marketing center and to modernize existing facilities. The objectives of the project were to promote the mood of an old market, while preserving its functions and efficiency as a market, to design outdoor spaces with natural resources and amenities in balance, and to create attractive tourist spots in connection with the wide area development plan. The project was oriented, fast, to enhance the functions of the market. For this purpose, a multi-dimensional space layout was designed in consideration of functions as a wholesale market. The safety of pedestrians was secured by separating lathes for vehicles and for pedestrians. Tree planting with various functions such as sheltering, wind breaking and guiding was planned. Secondly, nature-friendly and human-friendly landscaping design was attempted. For this, the beautiful natural resources of Amnam Park were utilized, and green spaces such as green bridges linking buildings in the wholesale market, and rooftop gardens were to be arranged. In addition, environment-friendly facilities such as roads paved with natural materials(i.e. gravel, shells) and program parking lots were to be planned. Thirdly, landscape design was considered to create attractive tourist spots. For example, a fish farm was created as a theme street for pedestrians and various water-friendly spaces such as pedestrian ramps, observatories and seaside streets were to be secured. The main contents are as follows. First, a green bridge to Ahnnam Park was introduced for a tour source and flower garden, an event plan and viewing deck open to the sea were planned on the bridge's axis. Secondly, for the effective land use plan concerning open space and convenience to visitors, a promenade was planned, which is connected with the theme plaza and small plazas by environmental sculptures in front of the market hall and at the gate. As well, an observatory and a roof garden help create three dimensional multi leveled space, with a good view of the natural landscape of the sea, sky and park Thirdly, landscape materials, such as trees and those for facilities, strengthened for protection against the seawind and salt damage were selected. The commercial market area was intended to be transformed a traditional functional area of efficiency and economy into an attractive marine leisure area where both tourists and neighbors can make use of it.