• 제목/요약/키워드: Out of the Dust

검색결과 486건 처리시간 0.028초

CAPTURE OF YELLOW DUST BLOW BY MODIS DATA

  • Song, Jie;Park, Jong-Geol;Yasuda, Yoshizumi
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.920-922
    • /
    • 2003
  • Large plumes of yellow send or yellow dust blow out over the Sea of Japan and the Japanese archipelago from mainland of China. In this study, the methodology to capture the perspective on the large Yellow dust storm by using MODIS data is discussed. As the typical image of yellow send, MODIS data obtained of April 8, 2002 were used in this study.

  • PDF

시정자료를 이용한 황사의 미세먼지 농도추정 방법 연구 (Study of Methodology for Estimating PM10 Concentration of Asian Dust Using Visibility Data)

  • 이효정;이은희;이상삼;김승범
    • 대기
    • /
    • 제22권1호
    • /
    • pp.13-28
    • /
    • 2012
  • The $PM_{10}$ concentration data is useful for indentifying intensity and a transport way of Asian dust. However, it is difficult to identify them properly due to the limited spatial resolution and coverage. Therefore, a methodology to estimate $PM_{10}$ concentration using visibility data obtained from synoptic observation was developed. To derive the converting function, correlation between visibility and $PM_{10}$ concentration is investigated using visibility and $PM_{10}$ concentration data observed at 20 stations in Korea from 2005 to 2009. To minimize bias due to atmospheric moisture, data with higher relative humidity over a critical value were eliminated while deriving $PM_{10}$-visibility relationship. As a result, an exponentially decreasing function of visibility is obtained under the condition that relative humidity is less than 82%. Verification of the visibility converting function to $PM_{10}$ concentration was carried out for the dust cases in 2010. It was found that spatial distributions of $PM_{10}$ calculated by visibility are in good agreement with the observed $PM_{10}$ distribution, especially for the strong dust cases in 2010. And correlation between the derived and observed $PM_{10}$ concentration was 0.63. We applied the function to obtain distributions of $PM_{10}$ concentration over North Korea, in which concentration data are not available, and compared them with satellite derived dust index, IODI distributions for dust cases in 2010. It is shown that the visibility function estimates quite similar patterns of dust concentration with IODI image, which suggests that it can contribute for prediction by indentifying transport route of Asian dust.

pH 변화에 따른 산업종류별 오니류의 중금속 용출특성에 관한 연구 (A Study on the Elution Characteristics of Heavy Metals from the Industrial Sludges by the Variation of pH)

  • 박종환;정문식
    • 한국환경보건학회지
    • /
    • 제20권2호
    • /
    • pp.14-21
    • /
    • 1994
  • This study was carried out to find out the elution characteristics of 4 kinds of sludges and a dust by the variation of pH. Four kinds of sludges were obtained from the Industrial wastes, and the dust, from the iron-and-steel waste. These samples were analyzed by "Official Method for Waste", and the results were summarized as follows. 1. The amounts of heavy metals The concentrations of Cu were 1,940

  • PDF

키토산을 이용한 탄진수 응집제 개발 및 평가 (Development and Evaluation of Coal-dust Water Flocculant using Chitosan)

  • 홍웅길;나재운;정경원
    • 공업화학
    • /
    • 제32권2호
    • /
    • pp.139-142
    • /
    • 2021
  • 석탄 화력발전소는 석탄을 주원료로 사용하고 있으며, 석탄 이동 시에 석탄의 분진 및 자연 발화가 발생하게 되는데, 이를 방지하기 위해 물을 분사하는 작업을 수행한다. 이로 인해 석탄의 분진과 물이 함께 섞여 흘러나오는 일명 '탄진수(coal-dust water)'라고 불리는 폐수가 흘러나와 환경오염을 초래한다. 본 연구에서는 이러한 문제점을 해결하기 위해 미세한 분진까지 응집하여 물을 정화할 수 있는 키토산 기반의 천연 응집제를 개발하고, 그 응용성을 입증하고자 하였다. 탄진수에 다양한 농도의 응집제를 투여하여 최적의 흡착농도가 4 ppm임을 규명하였고, 투과도 및 탄진 제거효율을 통해 개발된 물질의 탄진 응집능이 매우 우수함을 확인하였다. 또한, MTT assay를 통해 응집제의 세포독성을 평가하여 독성이 전혀 없음을 입증함으로써, 본 연구에서 개발된 응집제가 인간 및 자연 생태계에 영향을 주지 않고 효과적으로 탄진을 응집할 수 있는 물질임을 규명하였다.

치과기공사의 분진노출 수준 및 개인보호구 착용 실태 - 대구지역을 중심으로 - (Assessment of dust exposure and personal protective equipment among dental technicians)

  • 박수철;전만중;사공준
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.93-102
    • /
    • 2011
  • Purpose: The study aimed to evaluate working environment for dental technician by measuring dust level, ventilation conditions and the use of personal protective equipment and to provide basic information required to improve working environment and develop health education programs for dental technician. Methods: A total of 240 dental technician who are registered with the Daegu Association of Dental technician and working at 34 dental laboratories participated in the study. And the dust level was measured at 21 different spots in 16 dental laboratories out of 34. Results: Of 34 dental laboratories, 31 (91.2%) were equipped with a ventilator, but the remaining 3 (8.8%) did not have a ventilator. By the number of ventilator, 1 to 3 ventilators were found in 22 dental laboratories (71.0%), 4 to 6 ventilators were in 7 laboratories (22.5%) and more than 7 ventilators in 2 laboratories(6.5%). According to the frequence of changing filters in dust collector, 20 dental laboratories (58.9%) changed filters every four weeks, 10 laboratories (29.4%) changed them every six weeks and 4 laboratories (11.7%) changed them every eight weeks. Of total respondents, 114 (61.3%) said they wore a mask all the time while working, 56 (29.6%) said they frequently wore a mask, 19 (10.1%) said they did not wear a mask. As for the type of masks, 159 (84.1%) used a disposable mask, 25 (13.2%) used a cotton mask and 5 (2.7%) used an anti-dust mask. For dust sat on their outfits while working, 102 (54.0%) shook their uniforms inside workplace to keep dust off the uniforms, 64 (33.9%) did not anything until they wash their uniforms and 23 (12.1%) shook their uniforms outside workplace to keep dust off the uniforms. Of total respondents, 182 (96.3%) had a particle in their eyes while carrying out grinding work. Based on the measurement of floating dust at workplace, 3 dental laboratories showed dust concentration exceeding the minimum level of 10 mg/$m^3$ allowed under the permit for environment. Of those, 1 laboratory had the dust concentration that was more than 1.5 times higher than the minimum level. Dust concentration was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Dust comprised of nickel (more than 70%), chrome (9%) and others. The mean chrome concentration was more than twice higher than the minimum permissible level of 0.5 mg/$m^3$. There were two laboratories that showed chrome concentration exceeding the level of 0.4 mg/$m^3$. Like dust concentration, chrome level was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. There were six laboratories that had nickel concentration exceeding the minimum permissible level of 1 mg/$m^3$. Of those, one laboratory had nickel concentration that was more than three times higher than the minimum permissible level. Nickel concentration was also higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Conclusion: It is not likely that heavy metal concentrations found in the study constitute respiratory dust. It is however necessary for health of dental technician to apply the Industrial Safety and Healthy Law to dental laboratories and make recommendations for the use of personal protective equipment, installation of a proper number of ventilators, more frequent change of filters in dust collector and improved ventilation for polishing work. At the same time, dental technician need education on how to use personal protective equipment and how to efficiently remove dust from their uniforms.

건설현장에서 발생하는 비산먼지의 실태 및 영향에 관한 연구 (A Study on the Actual Condition and Effect of Dust Scattering in Construction Field)

  • 유희종;한경연;곽광수;김재수;양극영
    • 한국건축시공학회지
    • /
    • 제4권4호
    • /
    • pp.109-115
    • /
    • 2004
  • Dust scattering is one of the major problem for the residents living nearby construction field with construction noise and vibration. The dust scattering may inflict a considerable damage to psychological, spiritual discomfort to neighboring peoples. Therefore, the trouble of residents living nearby construction field have been increasing. Nevertheless, in our country, adequate guidelines for the dust scattering are not yet established because of the lack of basic data and insufficient research works. In this point, this study has researched its level of damage by conducting of the interview-survey which utilizing of questionnaire-paper asking for those staffs and workers to answer in the construction field, in order to grasp the damage extent of the actual condition effect and response against scattering dust in construction field. As the result, the occurring rate of dust scattering was appeared high compare with other constructing processes, due to utilization of construction equipment that operating at the fundamental basic construction stage, and it was turned out that presently the proper countermeasure and training against scattering dust in the construction site is insufficient. As for the solution mean against that, it is considered that with the better operation of construction site such as the installation of facilities for occurrence-restraint of dust scattering, frequent sprinkling of water, use of thermostat-covers, as well as those methods to be minimized of the occurrence of dust scattering must be contrived through the education for an attention how to use of construction equipment and training at the site.

Asian Dust Transport during Blocking Episode Days over Korea

  • Moon, Yun-Seob;Kim, berly-Strong;Kim, Yoo-Keun;Lim, Yun-Kyu;Oh, In-Bo;Song, Sang-Keun;Bae, Joo-Hyon
    • 한국환경과학회지
    • /
    • 제11권2호
    • /
    • pp.111-120
    • /
    • 2002
  • Asian dust(or yellow sand) occurs mainly in spring and occasionally in winter in east Asia, when the weather conditions are under an upper trough/cut-off low and surface high/low pressure system during blocking episode days associated with the stationary patterns of the upper level jet stream. The transport mechanism for Asian dust during the blocking episode days in spring 2001 was analyzed using the TOMS aerosol index and meteorological mesoscale model 5(MM5). Based on the E vector, an extension of an Eliassen-Palm flux, the blocking episode days were found to be associated with the development of an upper cut-off low and surface cyclones. Concurrently, the occurrence of dust storms was also determined by strong cold advection at the rear of a jet streak, which exhibited a maximum wind speed within the upper jet stream. As such, the transport mechanism for Asian dust from China was due to advection of the isentropic potential vorticity(IPV) and isentropic surfaces associated with tropopause folding. The transport heights for Asian dust during the blocking episode days were found to be associated with the distribution of the isentropes below the IPV At the same time, lee waves propagated by topography affected the downward motion and blocking of Asian dust in China. The Asian dust transported from the dust source regions was deposited by fallout and rain-out with a reinforcing frontogenesis within a surface cyclone, as determined from satellite images using TOMS and GMS5. Accordingly, these results emphasize the importance of forecasting jet streaks, the IPV, and isentropes with geopotential heights in east Asia.

테르밋 반응을 이용한 페로망간 전기로 분진의 재활용에 관한 연구 (Recovery of manganese compounds from electric arc furnace dust by Aluminothermy Process)

  • 하태영;조영민;박영구;김윤채
    • 한국응용과학기술학회지
    • /
    • 제32권1호
    • /
    • pp.23-30
    • /
    • 2015
  • The properties of dust collected from electric arc furnace of ferro manganese production units was investigated, and also the metallic manganese was recovered from the dust by aluminothermy process. The ferromanganese dust collected from electric arc furnace contained about 15% of manganese oxide ($Mn_3O_4$) and 9% of carbon as the contaminant, and have a 5um of 50% median diameter and irregular particle shape. The carbon contaminant in the dust could be reduced until about 0.1~0.5% level by roasting in the air at a temperature of 600~900C for 60minutes. The recovery of manganese could not be carried out using only ferromanganese dust from electric arc furnace by aluminothermy process, but the ferromanganese which contained manganese of about 92% and iron of about 5% could be obtained from the mixture of ferromanganese dusts from electric arc furnace and converter. The best mixing condition of dust fixed at electric arc furnace dust / converter dust ratio of 1:9 and 2:8, and the mixing rato of 3:7 or more could not separated the metal and slag from the reactant after aluminothermy reaction.

Pb Splashing 합금으로부터 Zn정련에 관한 연구 (A Study on the Purification of Zn from Pb Splashing Alloy)

  • 박재욱;김용하;이대열;신형기;김진한;박성수;정원섭
    • 자원리싸이클링
    • /
    • 제6권4호
    • /
    • pp.3-10
    • /
    • 1997
  • Electric are furnace dust (EAF dust) generated in steel production based on scrap melting is contained Zn and Fe about 25 and 30 percent by weight, respectively. From a metallurgical point of view, the dust could be regarded as a raw material for Zn and Fe source. To recover the Zn in the metal from EAF dust, many system are proposed such as Arc Plasma Furmace and Pb splasher method. In this study, to recover high purity Zn from Pb splasing alloy, Zn distillation is carried out at the temperature of 1123, 1173, 1223, 1273 K, the gas flow rate of 2.5, 5.0, 8.0 Ni/min and the distilling time of 10, 30, 60, 90 minutes. The main results obtained from this study are as follows:(1) The amount of evaporated Zn and its evaporating rate increased with increasing temperature, but purity of Zn decreased with increasing temperature. Optimum temperature range was found out to be between 1173∼1223K. (2) The amount of evaporated Zn and evaporation rate increased with increasing gas flow rate at a given temperature and distillation time. Gas flow rate has more influence over the amount of evaporated Zn and evaporation rate with increasing temperature.

  • PDF

전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구 (A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization)

  • 하상안;임경택;신남철
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF