• Title/Summary/Keyword: Out of the Dust

Search Result 488, Processing Time 0.028 seconds

Study on the Variation of Optical Properties of Asian Dust Plumes according to their Transport Routes and Source Regions using Multi-wavelength Raman LIDAR System (다파장 라만 라이다 시스템을 이용한 발원지 및 이동 경로에 따른 황사의 광학적 특성 변화 연구)

  • Shin, Sung-Kyun;Noh, Youngmin;Lee, Kwonho;Shin, Dongho;Kim, KwanChul;Kim, Young J.
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.2
    • /
    • pp.241-249
    • /
    • 2014
  • The continuous observations for atmospheric aerosol were carried out during 3 years (2009-2011) by using a multi-wavelength Raman lidar at the Gwangju Institute of Science and Technology (GIST), Korea ($35.11^{\circ}N$, $126.54^{\circ}E$). The particle depolarization ratios were retrieved from the observations in order to distinguish the Asian dust layer. The vertical information of Asian dust layers were used as input parameter for the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model for analysis of its backward trajectories. The source regions and transport pathways of the Asian dust layer were identified. The most frequent source region of Asian dust in Korea was Gobi desert during observation period in this study. The statistical analysis on the particle depolarization ratio of Asian dust was conducted according to their transport route in order to retrieve the variation of optical properties of Asian dust during long-range transport. The transport routes were classified into the Asian dust which was transported to observation site directly from the source regions, and the Asian dust which was passed over pollution regions of China. The particle depolarization ratios of Asian dust which were transported via industrial regions of China was ranged 0.07-0.1, whereas, the particle depolarization ratio of Asian dust which was transported directly from the source regions to observation site were comparably higher and ranged 0.11-0.15. It is considered that the pure Asian dust particle from source regions were mixed with pollution particles, which is likely to spherical particle, during transportation so that the values of particle depolarization of Asian dust mixed with pollution was decreased.

A Study on the Correlation between Forest Fire Occurrence and Asian Dust during the Spring Season from 2000 to 2008 (2000~2008년 봄철 황사와 산불발생의 관계 분석)

  • Won, Myoung-Soo;Yoon, Suk-Hee;Lee, Woo-Kyun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.3
    • /
    • pp.148-156
    • /
    • 2011
  • The purpose of this study is to analyze the patterns of forest fire possibly related with Asian dust event and carry out a correlation analysis between forest fire occurrence and existence or not of the Asian dust event during dry seasons i.e. February to May in 2000 to 2008. To study the correlation of forest fire and Asian dust, we surveyed information of Asian dust observations, forest fire statistics, fire danger rating index, weather data such as temperature, relative humidity and wind speed of the day occurring the forest fire. As a consequence of analysis, the regional frequency of Asian dust was the highest in Gyeonggi and Chungbuk divisions. Frequencies of forest fire occurrence by the Asian dust events were the highest in the day before three days of the Asian dust event. The highest frequent regions of forest fire occurrence were district of boundary line between Gyeonggi and Western of Gangwon, Chungbuk and Gyeonbuk inland. The correlation between forest fire and fire danger rating index showed the high correlation with the day before three days and after three days of the Asian dust event. These correlation coefficients were 0.50038 and 0.53978 to 1% significance level. The result of analysis between the frequency of forest fire occurrence and wind speed had a highly negative relationship at all the Asian dust days, the day before and after three days. The correlation coefficients had been -0.58623 to -0.61245 to 1% significance level. Relative humidity showed a little of negative relationship with forest fire occurrence in -0.2568(p ${\leq}$ 0.01) for the Asian dust day and -0.35309(p ${\leq}$ 0.01) for next three days. Moreover, at the day before three days of Asian dust events, it was -0.23701 to 1% significance level. However, the mean temperature did not correlate with frequency of forest fire occurrence by Asian dust events at all.

Association between Perceived Susceptibility to Fine Dust Exposure and Wearing Masks, Attitude toward Respiratory Disease Prevention Education in Farmers (농업인의 미세먼지 노출에 대한 인지된 감수성과 마스크 착용 및 호흡기질환 예방교육 참여 태도와의 연관성)

  • Jung, HyeJeong;Lee, YunJin;Lee, SooYeon;Han, JiYoung;Kim, YangWoo;Lee, Soo-Jin
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.2
    • /
    • pp.78-88
    • /
    • 2021
  • Objectives: This study aimed to investigate health risk awareness pertaining to fine dust exposure and the use of face masks in farmers, as well as their attitude toward education regarding fine dust-related respiratory disease prevention. Methods: In total, 295 farmers were interviewed in a survey using a structured questionnaire to obtain data on general characteristics, farming-related characteristics, health risk awareness pertaining to fine dust exposure, attitude toward education on fine dust-related respiratory disease prevention and the use of face masks. This study was analyzed the correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention. Results: The mean score for perceived susceptibility to fine dust exposure was 3.8 (out of 5), and the participants were highly willing to receive education on fine dust-related respiratory disease prevention. In Multiple response analysis of reactions to exposure to fine dust generated during work, 221 participants responded that they practiced at least one preventive action; participants gave a positive response to "wearing masks" (56.1%), "personal hygiene, such as hand washing." (52.9%). In terms of education methods, 94 (33.6%) participants preferred to learn online or via text messages. Conclusions: The significant correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention shows the importance of promoting education on prevention. The results of this study can help understand as reference for education on fine dust-related respiratory disease prevention.

Study on the Thermal Characteristic Comparison of Fire.Explosion Hazard of Fugitive Dust Generated in the Manufacturing Process (제조공정상 발생하는 비산분진의 화재·폭발 위험성에 대한 열적특성 비교에 관한 연구)

  • Sun, Ko Jae
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.71-83
    • /
    • 2014
  • This study carried out an experiment in order to compare thermal characteristics after collecting dust generated in the process of disposing of waste tire, plywood flour in the process of manufacturing plywood, salicylic acid dust in the process of manufacturing functional soap, and dust in the process of manufacturing wheat powder, which has potential fire and explosion hazard. According to the results of experiment, the analysis showed that all samples subject to the experiment were in the condition where heat flux decreased and temperature decreased as the quantity of added talc was increased. This shows that decomposition rate decreased, and hazard decreased. However, in all of samples subject to the experiment, as heating rate increased, endothermic onset temperature moved to the low-temperature part, and the amount of absorbed heat was largely increased. This showed that the decomposition hazard of sample increased as heating rate increased, according to the analysis. Besides, TGA experiment results showed that thermal stability was secured because total weight loss decreased as the amount of talc was increased for all samples subject to the experiment regarding the ratio of weight loss. It is expected that the continuous research and supplementation of dust explosion mechanism in the future will contribute to the establishment of measures for the effective dust explosion prevention.

Characteristics of Typhoon in 2006 and Improvement of Typhoon Forecast (2006년 태풍 특징과 태풍 예보의 개선방향)

  • Cha, Eun-Jeong;Lee, Kyung-Hi;Park, Yun-Ho;Park, Jong-Sook;Shim, Jae-Kwan;In, Hee-Jin;Yoo, Hee-Dong;Kwon, Heok-Joe;Shin, Do-Shick
    • Atmosphere
    • /
    • v.17 no.3
    • /
    • pp.299-314
    • /
    • 2007
  • The purpose of this study is to summarize tropical cyclone activity in 2006. Twenty three tropical cyclones of tropical storm (TS) intensity or higher formed in the western North Pacific and the South China Sea in 2006. The total number is less than the thirty-year (1971~2000) average frequency of 26.7. Out of twenty three tropical cyclones, fifteen cyclones reached typhoon (TY) intensity, while the rest eight cyclones only reached severe tropical storm (STS) and tropical storm (TS) intensity - three STS and five TS storms. The tropical cyclone season in 2006 began in May with the formation of CHANCHU (0601). The convective activity was slightly inactive around the Philippines from late June to early August. In addition, subtropical high was more enhanced than normal over the south of Japan from May to early August. Consequently, most tropical cyclones formed over the sea east of the Philippines after late June, and many of them moved westwards to China. CHANCHU (0601), BILIS (0604), KAEMI (0605), PRAPIROON (0606) and SAOMI (0608) brought damage to China, the Philippines, and Vietnam. On the other hand, EWINIAR (0603) moved northwards and hit the Republic of Korea, causing damage to the country. From late August to early September, convective activity was temporarily inactive over the sea east of the Philippines. However, it turned active again after late September. Subtropical high was weak over the south of Japan after late August. Therefore, most tropical cyclones formed over the sea east of the Philippines and moved northwards. WUKONG (0610) and SHANSHAN (0613) hit Japan to bring damage to the country. On the other hand, XANGSANE (0615) and CIMARON (0619) moved westwards in the South China Sea, causing damage to the Philippines, Thailand, and Vietnam. Another special feature in 2006 tropical cyclone activity is that IOKE (0612) formed in the central North Pacific crossed 180 degree longitude and moved into the western North Pacific. It has been four years since HUKO (0224) in 2002.

The optical spectra of zodiacal light

  • Yang, Hongu;Ishiguro, Masateru
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.60.1-60.1
    • /
    • 2013
  • Numerous dust particles are scattered in the interplanetary space of the solar system (Interplanetary Dust Particles; IDPs). The origin of the IDPs is one of the major questions in the solar system astronomy because IDPs are being removed from the solar system within a few million years by photon drag. Comets and asteroids were pointed out as the possible sources of IDPs. Although several dust supplying mechanisms from comets and asteroids have been revealed, amount of contribution from each sources are still not clear. Zodiacal light is sunlight scattered by IDPs. Spectra of zodiacal light can supply important observational clue to reveal the origin of the IDPs, because comets and each type of asteroids have different kind of spectra. However, reflectance spectrum of zodiacal light was not measured at the wavelength of weak atmospheric contamination. We measured the reflectance spectra of zodiacal light from $5000{\AA}$ to $7000{\AA}$. We used open data obtained by the Subaru/FOCAS instruments archived in the SMOKA database. From the longslit spectrum data, we measured spectrum of sky background and estimated flux from the sources other than the zodiacal light. We compared it with the spectra of each type of minor bodies in the solar system, and meteorites originated from these bodies.

  • PDF

A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter (정전형여과집진방식에서 여과특성에 관한 연구)

  • 천중국;박출재;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

Numerical Analysis on the Ventilation System Improvement in Air Shot Blast Room (Air Shot Blast 작업실 내부 환기 시스템 개선에 관한 수치해석)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.861-868
    • /
    • 2022
  • The purpose of this study is to design an effective atmospheric environment system through the design of the dust collection in the air shot room being operated in a domestic shipyard. The ventilation system in the current air shot room mostly uses a dust collecting filter to filter internal particles and releases them in the atmosphere. A conventional design was made too much. In order to prevent an error and draw an optimal design, Computational fluid dynamics (CFD) tried to be applied only to air shot room. In the advanced design technique, computer simulation was conducted to secure basic design data. In order to find the basic design of the ventilation system and the flow field in the air shot room at propeller mold workplace of a shipyard, the CFD was conducted. In the case of Model-1 as a conventional workplace, where air flows in the inlet due to the subatmospheric pressure generated by inhalation of an air blower and flows out to the outlet, a discharge flow rate was somewhat low, and there was the holdup zone in the room. In the case of Model-2 as an improved model, the ventilation system was improved in the Push-Pull type, and the holdup of the internal flow field was improved.

The Improvement of Collection Efficiency of Electrostatic Precipitator (전기 집진기의 집진 효율 향상에 관한 연구)

  • Ahn, Kook-Chan;Kim, Bong-Hwan;Lee, Gwang-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.25-30
    • /
    • 2002
  • This paper demonstrates the effects of dust electrical resistivity on electrostatic precipitability. The effects of gas temperature, velocity and humidity on the collection efficency were considered by used of coal fly ashes from fluidized bed combustion boiler. The experiments for collection efficiency were carried out in the pilot plant. The ashes which have non-spherical geometry and high electrical resistivity were used. Electrical resistivity is an important property for the collection efficiency in the electrostatic precipitators. Fly ash resistivity as a function of temperature up $350{\circ}C$ and water concentration(up to 15%) has been experimentally investigated using the resistivity test equipment consisted of the movable electrode, dust cup, and furnace. As the resistivity of fly ash in the operating temperature($150{\circ}C$) of an electrostatic precipitator was measured higher than $1010{\Omega}{\cdot}$cm, flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash is required.

Environmental Hazardous Assessment on Wood Panel Manufacturing Process (목재판넬 제조공정의 환경위험성평가)

  • Lee, Su-Gil;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.13-21
    • /
    • 2007
  • Personal and static sampling for formaldehyde, wood dust and noise monitoring, in accordance to the equipment running on the day, were carried out throughout wood panel manufacturing process. Even though the exposure level of formaldehyde and wood dust were below than exposure criteria, but the personal protective equipment(PPE) for those should be worn to everyone in the process because of its potential characteristics like carcinogenicity. Also a few local air extraction system above the cutting, grinding sections and organic blending room should be required. Most of the exposures of noise exposure were exceeded permitted exposure criteria, in case of Hopper operators, exposed to maximally 94dB(A) as LAeq 8hr, therefore active controls like PPE, monitoring, isolation etc. are necessary. The main sources of noise were caused on compressed air of the machinery, radio sound and operation noise like running machines, conveying, cutting, sawing, moving vehicles, storing and so on. For the comparison of control criteria in each country, the permitted exposure standards for above hazardous materials and noise in Korea, ACGIH and Australia were discussed. We have recognized that the Korean criteria should be discussed urgently to give the right information to employee and modified, if it is necessary.