Study on Minimizing Electromagnetic Interference to Capture Vortex Structures in Turbulent Boundary Layer (경계층 유속 정밀도 증가를 위한 전자파 간섭 최소화 연구)

  • Dong-Hoon Kang;Yong Duck Kang
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2024
  • To measure the vortex structures within the turbulent boundary layer, a hot-wire sensor was mounted on a stepper motor controller and moved to the designated measurement points. Near the surface within the flow field, the velocity is relatively slow, making the measurements highly sensitive to electromagnetic interference (EMI) during signal processing. This EMI primarily originates from the power supplies of computers and other electronic equipment. In our experimental setup, EMI was introduced into BNC cables connected to the hot-wire sensor from the powered stepper motor. When power was supplied to the motor controller to move the hot-wire sensor, EMI appeared on the oscilloscope screen. Consequently, unexpected noise was present in the data measured by the hot-wire sensor. To mitigate this and enhance the signal-to-noise ratio (SNR) during measurements, the connecting cables were shielded, and an old computer without EMI shielding was replaced.

Study on Strain Measurement of Agricultural Machine Elements Using Microcomputer (Microcomputer를 이용(利用)한 농업기계요소(農業機械要素)의 Strain 측정(測定)에 관(關)한 연구(硏究))

  • Kim, Kee Dae;Kim, Tae Kyun;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.8 no.1
    • /
    • pp.90-96
    • /
    • 1981
  • To design more efficient agricultural machinery, the accurately measuring system among many other factors is essential. A light-beam oscillographic recorder is generally used in measuring dynamic strain but it is not compatible with the extremely high speed measuring system such as 1,000 m/s, also is susceptable to damage due to vibration while using the system in field. The recorder used light sensitive paper for strip chart recording. The reading and analysis of data from the strip charts is very cumbersome, errorneous and time consuming. A microcomputer was interfaced with A/D converter, microcomputer program was developed for measuring, system calibration was done and the strain generated from a cantilever beam vibrator was measured. The results are summarized as follows. 1. Microcomputer program was developed to perform strain measuring of agricultural machine elements and could be controled freely the measuring intervals, no. of channels and no. of data. The maximum measuring speed was $62{\mu}s$. 2. Calibration the system was performed with triangle wave generated from a function generator and checked by an oscilloscope. The sampled data were processed using HP 3000 minicomputer of Chungnam National University computer center the graphical results were triangle same as input wave and so the system have been out of phase distorsion and amplitude distorsion. 3. The strain generated from a cantilever beam vibrator which has free vibration period of 0.019 second were measured by the system controlled to have l.0 ms of time interval and its computer output showing vibration curve which is well filted to theoretical value. 4. Using microcomputer on measuring the strain of agricultural machine elements could not only save analyzing time and recording papers but also get excellent adaptation to field experiment, especially in measurement requiring high speed and good precision.

  • PDF

The Effect of Repetitive Insertion and Pullout of Spinal Screws on Pullout Resistance : A Biomechanical Study (척추 수술에 사용되는 나사못의 반복 삽입과 인출이 인장항력에 미치는 영향 : 생체 역학적 연구)

  • Bak, Koang Hum;Ferrara, Lisa;Kim, Kwang Jin;Kim, Jae Min;Kim, Choong Hyun;Benzel, Edward C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.131-136
    • /
    • 2001
  • Object : The clinical uses of screws are increasing with broader applications in spinal disorders. When screws are inserted repeatedly to achieve optimal position, tips of screw pitch may become damaged during insertion even though there are significant differences in the moduli of elasticity between bone and titanium. The effect of repeated screw insertion on pullout resistance was investigated. Methods : Three different titanium screws(cortical lateral mass screw, cancellous lateral mass screw and cervical vertebral body screw) were inserted into the synthetic cancellous material and then extracted axially at a rate of 2.4mm/min using Instron(Model TT-D, Canton, MA). Each set of screws was inserted and pulled out three times. There were six screws in each group. The insertional torque was measured with a torque wrench during insertion. Pullout strength was recorded with a digital oscilloscope. Results : The mean pullout force measurements for the cortical lateral mass screws($185.66N{\pm}42.60$, $167.10N{\pm}27.01$ and $162.52 N{\pm}23.83$ for first, second and third pullout respectively : p=0.03) and the cervical vertebral body screws($386.0N{\pm}24.1$, $360.2N{\pm}17.5$ and $330.9N{\pm}16.7$ : p=0.0024) showed consecutive decrease in pullout resistance after each pullout, whereas the cancellous lateral mass screws did not($194.00N{\pm}36.47$, $219.24N{\pm}26.58$ and 199.49N(36.63 : p=0.24). The SEM after insertion and pullout three times showed a blunting in the tip of the screw pitch and a smearing of the screw surface. Conclusions : Repetitive screw insertion and pullout resulted in the decrease of pullout resistance in certain screws possibly caused by blunting the screw tip. This means screw tips suffer deformations during either repeated insertion or pullout. Thus, the screws that have been inserted should not be used for the final construct.

  • PDF

Characteristics of Random Jitter in Analog Fiber-Optic Links Employing a Mach-Zehnder Modulator and an EDFA (마하-젠더 광 변조기와 EDFA를 사용한 아날로그 광통신 링크의 랜덤 지터 특성)

  • Yoon, Young-Min;Lee, Min-Young;Shin, Jong-Dug;Kim, Boo-Gyoun
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.96-102
    • /
    • 2009
  • We investigate the characteristics of RJ (random jitter) in an analog fiber-optic link employing a MZM (Mach-Zehnder modulator) and an EDFA (Erbium-doped fiber amplifier). RJ has been measured using two methods, one of which derived from the noise spectrum of a RF spectrum analyzer and the other from the histogram data of a sampling oscilloscope. If the optical power and/or the RF power input to the MZM increase, RJ decreases due to the output signal power increase. For the optical link without EDFA, the minimum RJ is about 1 ps at an RF power of 10 dBm and an optical power of 8 dBm measured using the noise spectrum method. For the optical link with an EDFA, RJ decreases toward a jitter floor as the EDFA gain increases. If the gain increases further, it has been observed that RJ increases from the minimum. If the EDFA gain is fixed, RJ is smaller for the case of larger optical input power. As the EDFA gain increases, RJ reduction rate becomes greater for the case of lower optical input power.

  • PDF

Design and Analysis of a 12 V PWM Boost DC-DC Converter for Smart Device Applications (스마트기기를 위한 12 V 승압형 PWM DC-DC 변환기 설계 및 특성해석)

  • Na, Jae-Hun;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.239-245
    • /
    • 2016
  • In this study, a 12 V PWM boost converter was designed with the optimal values of the external components of the power stage was well as the compensation stage for smart electronic applications powered by a battery device. The 12 V boost PWM converter consisted of several passive elements, such as a resistor, inductor and capacitor with a diode, power MOS switch and control IC chip for the control PWM signal. The devices of the power stage and compensation stage were designed to maintain stable operation under a range of load conditions as well as achieving the highest power efficiency. The results of this study were first verified by a simulation in SPICE from calculations of the values of major external elements comprising the converter. The design was also implemented on the prototype PCBboard using commercial IC LM3481 from Texas Instruments, which has a nominal output voltage of 12 V. The output voltage, ripple voltage, and load regulation with the line regulation were measured using a digital oscilloscope, DMM tester, and DC power supply. By configuring the converter under the same conditions as in the circuit simulation, the experimental results matched the simulation results.

CHANGES OF JAW-OPENING REFLEX DEGREE ACCORDING TO ELECTROACUPUNCTURE DURATION ON ZUSANLI (족삼리의 전기침 자극에 대한 개구반사 크기의 변화)

  • Seo, Young-Ah;Song, Hyung-Geun;Na, Chang-Su;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.788-796
    • /
    • 1998
  • The purpose of this study was to investigate the effect of various electroacupuncture duration induced by acupuncture point-Zusanli ($S_{36}$) electrical stimulation on inhibition of amplitude of digastric electromyogram (dEMG) evoked by noxious electrical stimuli around the mental foramen. intraperitoneal sodium pentobarbital in an initial dose of 50mg/kg and maintenance doses of 4.5mg/kg/h were given through a cannula in the femoral vein using a constant infusion pump. A pair of stimulating electrodes were inserted for noxious stimuli around the mental foramen. An irritant electronic stimuli pulse (0.2 Hz, 0.1 ms duration) was produced with an intensity of about $1.5{\times}2$ times threshold for evoking the dEMG. The anterior belly of the digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for dEMG recording. Acupuncture point stimulation on Zusanli (2 Hz, 250 ${\mu}s$, biphasic pulse, 2 V) was delivered by Dental Electronic Anesthesia (3M, U.S.A). For periods of electronic stimulation of 10, 20, and 30min, the amplitudes of dEMG were measured on the oscilloscope and on the monitor connected to the amplifier. The following results were obtained: The dEMG was decreased to 73.4% of that in the control set after 10 min electroacupunture stimulation (Group I); The dEMG was decreased to 77.1% (10min), 54.0.% (20min) of that in the control set after 20minutes of electroacupunture stimulation (Group II). The dEMG was decreased to 73.3% (10min), 61.9% (20min), 76.2% (30min) of that in the control set after 30 min of electroacupunture stimulation (Group III). From these results, it may be that in the electroacupuncture stimulation on the Zusnali resulted in a reduction of amplitude of dEMG and that the most effective electroacupuncture stimulation period was 20min.

  • PDF

Response of Anchovy to Artificial Sounds (소리자극에 대한 멸치의 반응)

  • 김상한
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.57-62
    • /
    • 1978
  • When fisherman use the boat seine net to catch anchovy, a large noise (drum can, small drum and small gong) is used to scare the anchovy school along the wing nets, and into the bag net were they are caught. We want to know how much of an effect these s:mnds have on forceing the anchovy school towards the bag net. The underwater sounds of ancho\'y, drum can, small drum and small gong were analyzed in the labroatory. The behavioral responeses to the playback sounds of anchovy feeding and sounds of artificial instruments were also investigated. The feeding and artificial sounds of the samples were recorded by a tape recorder through a hydrophone in an anechoic aquarium. The sound intensity level was measured by means of a sound level meter in an anechoic chamber. The frequency and intensity of various sounds were analyzed with an analyzing system consisting of a ~-octave filter set, a high speed level recorder, an amplifier and an oscilloscope. The most successful recording was edited into a 9 to 10 second sound track and was repeated in a sequence of 9 to 10 second intervals. The sequence was then reproduced into an anechoic aquarium through the underwater speaker. The results of investigation are as follows; 1. The frequency of the feeding sound was 63~80Hz, and the pressure level produced was less than 32db. 2. The frequencies of the artificial sounds were 315~ 1,OOOHz, and the pressure levels were 88~95 db in the air. 3. When a hydrophone was placed 70cm below the surface with artificial sounds (drum can, small drum and small gong) produced 1 meter above the surface, the pressure level decreased about 30db. 4. The feeding sound was ineffective in attracting the anchovy, because of interference from ambient noise. 5. The artificial sounds had such a small effect on the anchovy's that they could not be used in ocean fisheries.

  • PDF

Development of a Sow Voice Analysis System for Forecasting Parturition Time (임신돈의 분만시기 예측을 위한 음성 분석 시스템 개발)

  • 장동일;임정택;임영일;한원석;박창식
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.121-130
    • /
    • 2000
  • Pure voice characteristics of sow were analyzed to predict parturition time. These were analyzed by using oscilloscope and Sound Forge and the results showed that the voice frequency and amplitude of sow were in the range of 30∼2,500Hz and -35∼-75dB. According to the sound analysis results, the frequencies of sound appearance from farrowing sow in the farrowing pen for three days prior to delivery day and eight hours of prior to delivery day and eight hours of prior to time were around 85% and 46%, respectively of the total appearance during eight days to delivery. Forecasting of delivery time of farrowing sow using the number of sound occurrences showed a promising result such that those have been increased whenever the delivery time was approached. The forecasting success rates were 100% for both of one day and six hours prior to the actual delivery.

  • PDF

Study on the Development of Optical Sensor Linear Fire Detection System Using Raman Scattering (라만산란을 이용한 광센서 선형 화재감지시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Lim, Woo-Sub;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.27-38
    • /
    • 2016
  • The paper reports the development of a distributed temperature sensing (DTS) system, which is a fire detection system using optical sensor linear detectors that depends on foreign and domestic technologies. This study accordingly analyzed the electrical signal patterns of Raman scattering light mainly used for temperature sensing among back-scattered light generated in optical fiber by using an oscilloscope. Through the measurement results, it could be verified that the Stokes signal patterns had little change by the temperature increase, but the temperature-sensitive anti-Stokes patterns had relative increase of the changes. This study developed a K-DTS system, which is an optical sensor linear fire detection system composed of an optical repeater and a receiver that can detect fires using Raman scattering light. It could be verified that the developed K-DTS system satisfied the type approval standards through the sensitivity tests using the rate of rise type and fixed temperature type sensitivity testers. In addition, performance experiments have been performed for performance evaluation of the K-DTS system developed in comparison with S-DTS system which has been imported from abroad and widely used in Korea. It can be confirmed from the results of the performance experiments using model tunnels that comparable performances can be obtained in fire detection locations and the measurements of fire temperatures.

Flow characteristics analysis and test in the Pelton turbine for pico hydro power using surplus water (잉여 유출수를 이용한 소수력발전용 수차의 유동특성 해석 및 시험)

  • Jeong, Seon Yong;Lee, Kye Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2016
  • Computational fluid numerical analysis using the commercial code CFX was performed to develop a Pelton turbine for a pico hydro power generator using the circulating water of a cooling tower in a large building. The performance of the Pelton turbine was examined for different design factors, such as the bucket shape, in which the Pelton wheel was connected in an appropriate manner to the pipe section, and the number of buckets in order to find the optimal design of Pelton turbine for a pico hydro power using surplus water. A benchmark test was carried out on the manufactured small scale Pelton turbine to validate the design method of the Pelton turbine by numerical analysis. The results obtained by comparing the flow characteristics and power output measured using the ultrasonic flowmeter, the pressure transducer and the oscilloscope with the numerical results confirmed the validity of the analytical design method. The possibility of developing Pelton turbines for kW class pico hydro power generators using surplus water with an average circulation velocity of 1.2 m/s for the chosen bucket shape and number of buckets in a 30 m high building was confirmed.