• 제목/요약/키워드: Oscillation frequency shift

검색결과 27건 처리시간 0.021초

곡관내 자성유체 PLUG의 진동특성 (The Oscillation Characteristics of a Magneticfluid Plug in Curved Tube)

  • 전운학;이행남
    • 한국자동차공학회논문집
    • /
    • 제3권3호
    • /
    • pp.46-57
    • /
    • 1995
  • The aim of the present study is to provide fundamental informations for the development of magneticfluid actuator. To achieve the aim, oscillation characteristics of the magneticfluid plug are investigated by experiment for the various length and position of the magneticfluid plug and the frequency of magnetic field. The oscillation characteristics are obtained. Amplitude, natural frequency, phase shift and damping ratio, are compared with theoretical values. From the study, the following conclusive remarks can be made. The experimental equation for the magnetic field is obtained. The critical magneticfluid length exists and its value is about 70mm. The range of the damping ratio and fluid loss coefficient obtained by experiment are 0.1~0.2 and 30~100, respectively. Comparison between experimental and theoretical results of oscillation characteristics shows good agreement in the high frequency range. Meanwhile, in the low frequency range, there appears little discrepancies(5% in the frequency and amplitude and 10% in phase difference and damping ratio) with each other.

  • PDF

울트라 내로우 갭 용접에서 갭 내 고른 아크입열 분포를 위한 상ㆍ하 토치요동 효과 (Effect of Up-and-Down Torch Oscillation for Providing Uniform Heat Input along the Sidewall of Gap on Ultra Narrow Gap Welding)

  • 김두영;나석주
    • Journal of Welding and Joining
    • /
    • 제21권3호
    • /
    • pp.85-91
    • /
    • 2003
  • Narrow gap welding has many advantages over conventional V-grooved butt welding such as high productivity, small deformation and improved mechanical property of joints. With narrower groove gap, less arc heat input is expected will all the other advantages of narrow gap welding. The main defects of narrow gap welding include the lack of root fusion, convex bead surface and irregular surface, all of which have negative effects on the next welding pass. This paper suggests an up-and-down torch oscillation for ultra narrow gap welding with gap size of 5mm and investigates the proper welding conditions to fulfill the reliable and high welding quality. First, GMA welding model was suggested for ultra narrow gap welding system with Halmoy's model referenced for wire melting modeling. And the arc length in ultra narrow gap was defined. Secondly, based on the experimental results of up-and-down torch oscillation welding, phase shift of current and wire extension length were simulated for varying oscillation frequency to show that weld the bead shape in ultra narrow gap welding can be predicted. As the result, it was confirmed that reliable weld quality in ultra narrow gap welding can be achieved with up-and-down torch oscillation above 15Hz due to its ability to provide uniform heat input along the sidewall of gap.

Ringing Frequency Extraction Method Based on EMD and FFT for Health Monitoring of Power Transistors

  • Ren, Lei;Gong, Chunying
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.307-315
    • /
    • 2019
  • Condition monitoring has been recognized as an effective and low-cost method to enhance the reliability and improve the maintainability of power electronic converters. In power electronic converters, high-frequency oscillation occurs during the switching transients of power transistors, which is known as ringing. The ringing frequency mainly depends on the values of the parasitic capacitance and stray inductance in the oscillation loop. Although circuit stray inductance is an important factor that leads to the ringing, it does not change with transistor aging. A shift in either the inside inductance or junction capacitance is an important failure precursor for power transistors. Therefore, ringing frequency can be used to monitor the health of power transistors. However, the switching actions of power transistors usually result in a dynamic behavior that can generate oscillation signals mixed with background noise, which makes it hard to directly extract the ringing frequency. A frequency extraction method based on empirical mode decomposition (EMD) and Fast Fourier transformation (FFT) is proposed in this paper. The proposed method is simple and has a high precision. Simulation results are given to verify the ringing analysis and experimental results are given to verify the effectiveness of the proposed method.

Blood Pressure Simulation using an Arterial Pressure-volume Model

  • Yoon, Sang-Hwa;Kim, Jae-Hyung;Ye, Soo-Young;Kim, Cheol-Han;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권1호
    • /
    • pp.38-43
    • /
    • 2008
  • Using an arterial pressure-volume (APV) model, we performed an analysis of the conventional blood pressure estimation method using an oscillometric sphygmomanometer with computer simulation. Traditionally, the maximum amplitude algorithm (MAA) has been applied to the oscillation waveforms of the APV model to obtain the mean arterial pressure and the characteristic ratio. The estimation of mean arterial pressure and characteristic ratio was significantly affected by the shape of the blood pressure waveforms and the cutoff frequency of high-pass filter (HPF) circuitry. Experimental errors result from these effects when estimating blood pressure. To determine an algorithm independent of the influence of waveform shapes and parameters of HPF, the volume oscillation of the APV model and the phase shift of the oscillation with fast Fourier transform (FFT) were tested while increasing the cuff pressure from 1 mmHg to 200 mmHg (1 mmHg/s). The phase shift between ranges of volume oscillation was then only observed between the systolic and the diastolic blood pressures. The same results were obtained from simulations performed on two different arterial blood pressure waveforms and one hyperthermia waveform.

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • 제2권2호
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

수정진동자를 이용한 메로시아닌 색소 LB막의 광반응 특성 (The analysis of the optical response of merocyanine LB films using QCM)

  • 강기호;김정명;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.434-436
    • /
    • 2000
  • In this study, we investigate the optical characteristics of merocyanine dye Langmuir-Blodgett(LB) film using the oscillation characteristics of quartz crystal. As results, the resistance and frequency shift at the parallel resonance under the UV irradiation is to be going down. This behaviour of resistance and frequency is different from the case of general mass adsorption into the organic film on the quartz crystal. Generally the frequency decrease of quartz crystal oscillator, which has been considered as mass loading, goes along with the resistance increase. Thus it has been suggested that the J-aggregate dissociation in merocyanine dye LB film by UV irradiation give rise to transformation of oscillation characteristics of quartz crystal.

  • PDF

SIW 구조를 이용한 저 위상잡음 전압 제어 평판형 복합공진기 발진기 설계 (Design of a Low Phase Noise Voltage Tuned Planar Composite Resonator Oscillator Using SIW Structure)

  • 이동현;손범익;염경환
    • 한국전자파학회논문지
    • /
    • 제25권5호
    • /
    • pp.515-525
    • /
    • 2014
  • 본 논문에서는 저 위상잡음을 갖는 전압 제어 평판형 복합공진기 발진기(Vt-PCRO: Voltage-tuned Planar Composite Resonator Oscillator)를 설계, 제작하였다. 설계된 발진기는 공진기, 2개의 위상천이기, 증폭기로 구성된다. 공진기는 dual mode SIW(Substrate Integrated Waveguide) 공진기를 이용하여 구성하였으며, 약 40 nsec의 높은 군지연을 갖도록 하였다. 2개의 위상천이기 중(PS1, PS2: Phase Shifter 1 및 Phase Shifter 2) PS1은 $360^{\circ}$의 위상천이량을 가지며, 제작된 발진기의 전송선로 길이에 관계없이 개루프 이득(open loop gain) 발진조건을 만족하도록 한다. PS2는 약 $70^{\circ}$의 위상천이량을 가지며 발진 주파수 조정용으로 사용된다. 증폭기는 제작 시 발생한 큰 삽입손실의 문제를 보완하기 위해 2단으로 구성하였다. 개루프 이득 측정을 통해 발진 조건을 만족하는 PS1의 전압을 측정한 뒤, 폐루프로 구성하여 발진기를 구현하였다. 발진기 측정 결과, 5.345 GHz의 발진 주파수에서, 위상 잡음은 100 kHz offset 주파수에서 -130.5 dBc/Hz를 얻었다. 이때 출력 전력은 약 3.5 dBm, 전기적 주파수 조정 범위는 0~10 V의 조정 전압에서 약 4.2 MHz를 보였다.

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1033-1036
    • /
    • 1998
  • In this research project, two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.685-688
    • /
    • 1998
  • In this research project, two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.365-368
    • /
    • 1998
  • In this research project two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF