• Title/Summary/Keyword: Orthotics

Search Result 122, Processing Time 0.032 seconds

The Evaluation of Custom Foot Orthotics for Injury Prevention of Joggers (달리기 동호인들의 상해예방을 위한 맞춤형 발 보장구의 평가연구)

  • Kim, Ro-Bin
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.19-30
    • /
    • 2006
  • The purpose of this study was to examine the effect of foot orthotics on the overall comfort and muscle activity during running. The subjects were 10 members from the joggers' club which consisted of 2 women and 8 men. These individuals ran on the treadmill by 4.0m/s speed with and without the custom foot orthotics. The data concerning the overall comfort was collected by a questionairre that examined the overall comfort, heel cushioning, forefoot cushioning, medio-lateral control, arch height, heel cup fit, shoe heel width, forefoot width, and shoe length The MegaWin ver. 2.1(Mega Electronics lid, Ma. Finland) was used to gain electromyography signals of the muscle activity; Tibialis anterior, medial gastronemius, lateral gastronemius, vastus lateralis, vastus medialis, biceps femoris, and rectus femoris were measured. The results of the study were as follows. 1. During running the overall comfort was higher for the foot arthotic condition than the nonorthotic condition. Among the inquiries the overall comfort showed the biggest difference comparing the two conditions. and the shoe heel width showed the highest score for contort. 2 The muscle activity of the biceps femoris, and vastus lateralis in the stance period decreased. due to the foot orthotics. The muscle activity of the vastus medialis in the swing period also decreased and the muscle activity tibialis anterior in the stance and swing stance decreased as well During running, orthotics showed positive result in foot comfort. The foot comfort related to decreased stress, muscle activity, and foot arch strain. Overall comfort and the adequate decrease of muscle activity were associated with injury prevention and the best method to prevent injury semms to be the maintenance of foot comfort.

Immobilization Effect and Abdominal Pressure of Newly-Developed Lumbosacral Spinal Orthosis during Task Performance (새롭게 개발한 요천추 보조기의 과제 수행 중 척추의 고정효과와 복부압력)

  • Jeon, Kyung Soo;Yang, Hee Seung;Jang, Soo Woong;Shin, Hee Dong;Lee, Yun kyung;Lee, Young;Lee, Seul Bin Na;Ahn, Dong Young;Sim, Woo Sob;Cho, Min;Cho, Kyu Jik;Park, Dong Beom;Park, Kwan Soo
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Objective: We evaluated the efficacy of a newly-developed spinal orthoses (V-LSO) by comparing the stabilizing effect, abdominal pressure, and comfort of 3 different semirigid LSOs (classic LSO, V-LSO, and Cybertech®) during various body movements. Method: Thirty healthy volunteers (23~47 years, 24 males, 6 females) were selected. A dual inclinometer measured the range of motion (ROM) while the participants performed flexion/extension and lateral flexion of the lumbar spine with 3 LSOs. The LSO's pressure on the abdominal surface was measured using 9 pressure sensors while lying, sitting, standing, flexion/extension, lateral flexion, axial rotation, and lifting a box. Comfort and subjective immobilization were analyzed by a questionnaire. Results: V-LSO had a statistically significant effect on flexion over Cybertech®. No significant differences were noted during extension and lateral flexion between the 3 LSOs. The abdominal pressure showed no significant differences while supine. While sitting, standing, and lifting a box, the mean abdominal pressure for V-LSO were significantly higher than those for Cybertech®. During lumbar flexion, the mean abdominal pressures for classic LSO and V-LSO were significantly higher than that of Cybertech®. For extension, lateral flexion and axial rotation, the abdominal pressure for V-LSO was significantly higher than those of classic LSO and Cybertech®. In the subjective analysis, V-LSO and Cybertech® scored best for comfort. Conclusion: The V-LSO and Cybertech® were more comfortable than the classic LSO, and hence, may have improved compliance with decreased discomfort. V-LSO may be superior to the other LSOs in restricting lumbar movement and increasing intraabdominal pressure.

Useful effect of a clinical shoe insole, Mubal®, as orthotics

  • Park, Chan-Lee;Go, Ji-Hyun;Han, Na-Ra;Moon, Hong-Hee;Seo, Min-Jun
    • CELLMED
    • /
    • v.5 no.2
    • /
    • pp.10.1-10.3
    • /
    • 2015
  • Arthritis is a major cause of joint pain, stiffness, and subsequent disability which adversely affects quality of life. Seriously, it can lead to long term social and psychological effects including loss of independence, depression, and anxiety. Arthritis is usually treated with joint replacement surgery or medications. However, the artificial joint is temporary and pharmacological measures have side effects, such as addiction or hypersensitivity. Thus, orthotics has been developed to improve arthritis as a nonpharmacological measure. The increased regional load across compartments of articular cartilage is an important factor in the cause of the arthritis. Mubal$^{(R)}$, a clinical shoe insole, has a sliding function to help people to walk straight and realign the body balance. The slide of Mubal$^{(R)}$ reduces the knee joint loading in patients with arthritis. In addition, pumping function of Mubal$^{(R)}$ can mitigate arthritis by stretching the squashed nerves from lumbar to cervical vertebral and actively circulating blood of pelvic limb. In addition, Mubal$^{(R)}$ could help to stimulate the growth plate. Therefore, Mubal$^{(R)}$ can be used for the child with short stature as well as patients with arthritis.

Gait Angle Prediction for Lower Limb Orthotics and Prostheses Using an EMG Signal and Neural Networks

  • Lee Ju-Won;Lee Gun-Ki
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.2
    • /
    • pp.152-158
    • /
    • 2005
  • Commercial lower limb prostheses or orthotics help patients achieve a normal life. However, patients who use such aids need prolonged training to achieve a normal gait, and their fatigability increases. To improve patient comfort, this study proposed a method of predicting gait angle using neural networks and EMG signals. Experimental results using our method show that the absolute average error of the estimated gait angles is $0.25^{\circ}$. This performance data used reference input from a controller for the lower limb orthotic or prosthesis controllers while the patients were walking.

Effects of Foot orthotic on Postrual sway (발보조기가 자세동요에 미치는 효과)

  • Song, Chang-Ho;Lee, Seung-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.99-107
    • /
    • 2004
  • The purpose of this study was to investigate the effect of foot orthotic on postural sway. Subjects were 15 patients(7 men and 8 women) who prescribed foot orthotic at B hospital and L rehabilitation medicine clinic in Seoul. Postural sway during a single limb stance was measured using the CMS 10 Measuring System when subjects positioned on the balance trainer under two treatment conditions(orthotic and nonorthotic). RCSP(resting calcaneal stance position) while subjects were standing on the glass plate was measured using the angle finder after subjects were positioned in prone to divide equally lower leg and calcaneus using the goniometer. The result was as follows. There were significant difference between postural sway of orthotic and nonorthotic conditions(t=4.888, 4.589, p<0.001), and the leg of the small RCSP within a subject has the small postural sway index($x^2=26.000$, p<0.001). In conclusion, foot orthotics provide structural support for detecting and controlling postural sway in patients prescribed foot orthotics.

  • PDF

Requirements Improvement Plan of Professional Engineer License for International Mutual Accreditation (국가간 상호인증을 위한 기술사 자격의 취득요건 개선방안)

  • Cho, Mun-Son;Yang, Sung-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.5
    • /
    • pp.157-165
    • /
    • 2007
  • Currently, there are two major problems in professional engineer(PE) licensure system in Korea to be accredited internationally. One is a incompleteness of system connecting the licensure and the accredited engineering education program and the other one is a insufficient working experience condition required for achieving PE license. Therefore, these two problems are setbacks hindering Korea's PE license accredited internationally. In this study, international tendency stream on mutual accreditation of PE license are reviewed first, and the PE licensure system of the major countries are compared and analyzed. Based on the results, requirements improvement plan are suggested and the gradual implementation method are suggested also.

Can prosthetic limbs made too quickly cause kidney damage?: a pilot study

  • Petrofsky, Jerrold S.;Browne, Mary;Jamshidi, Mahyar;Libo-on, Anthony;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.2
    • /
    • pp.119-124
    • /
    • 2014
  • Objective: The use of chemicals for building prosthetic sockets present the possibility of being hazardous and unsafe due to off-gassing. The purpose of the present study was to investigate if freshly made materials used in prosthetic sockets causes off-gassing that would penetrate the skin and cause damage to the kidneys or blood. Design: Cross-sectional study. Methods: In this research, the off-gassing effects during the initial curing process of styrene monomer, vinyl ester resin, epoxy methacrylate resin, benzene-1, 3-dimethaneamine, trimethylhexanedlamine, and paratertiarybutylphenol were analyzed. Acid detection strips were placed inside newly fabricated mock-prosthetic sockets and left overnight in a closed environment to find out if acid was present in the invisible fumes. The plastic was worn by 9 subjects and urinalysis was made after 48 hours to test for any kidney or blood toxicity of the resins. Results: After wearing the plastic cuff for 48 hours, the ratio of protein to creatinine in the urine was raised to an abnormal level in five out of nine subjects. Four out of the nine subjects showed normal protein to creatinine ratios after wearing the device. The results showed that damage to the kidney occurred from wearing the resins after curing in half of the subjects. Conclusions: It is very important to conduct patient intakes which includes the assessment of renal function. Off-gassing in vented chambers may be needed to protect both prosthetists and patients.

Case Study of Working Environment Improvement at Plastic Product Companies for Reducing the Musculoskeletal Disorders Risk Factors (근골격계 질환 유해요인 감소를 위한 플라스틱 제품 제조업체의 작업환경 개선 사례연구)

  • Kang, Young-Sig;Cho, Mun-Son;Yang, Sung-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The goal of this study is to propose the effective method of investigating the injurious factors and make improvement plans that prevents the workers against musculoskeletal disorders at plastic product companies and the same business field with similar working conditions and process. A questionnaire are adopted to analyze the symptoms of workers' musculoskeletal disorders, and ergonomic assessment methods such as RULA, OWAS are performed to find out harmful factors of workplace and working posture. Based on the result of the evaluation, to enhance the working environment, improvement of worktable, working space, tools, and outfit was suggested, and induction of mechanical system was also suggested. It can be concluded that the method and process described in this paper could be helpful for diagnosing the musculoskeletal disorders risk factors and making improvement plans to the plastic product companies and the same business field with similar working conditions and process.