• Title/Summary/Keyword: Orthophoria

Search Result 26, Processing Time 0.018 seconds

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

The Study of tear film stability for normal eyes in adults (성인 정상안의 눈물 안정성에 대한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun-Mi;Oh, Seung-Jin
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.4
    • /
    • pp.85-91
    • /
    • 2016
  • This study is to research the tear film stability for 48 eyes, agreed the purpose of study, didn't have no contact lens wearing and were tested all two times in a day. Their visual acuity was more than 0.8, corrective visual acuity more than 0.8, the fattest K-reading, apical corneal radius, was in 7.40~8.40mm, corneal astigment was less than 1.00D and orthophoria. The tests, tear scope test, tear film break up time test(TBUT) and schirmer test order, were performed their functions before and after their working at interval of 6 hours over. The tearscope test results was no difference, TBUT was no difference, although 1.2 seconds more in the afternoon, shcirmer test was decreased 2.0mm in the afternoon.

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

Discussion on Preliminary Test for Male High School Students in Gwang-ju Area (광주지역 남자 고등학생들의 예비검사에 대한 고찰)

  • Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.95-99
    • /
    • 2007
  • This study performed apreliminary test with male high school students in Gwangju metropolitan city in order to determine visual function information of high school students. For the items in this preliminary test, there were inquiry, test for long distance unaided visual acuity, pinhole visual acuity test, colour vision test, cover test and stereo test. Most complaint related to eye was about blurred vision (28.4%) and over 90% of subjects had one or more, and among them, over 50% appealed two or more complaints. 76.1% of all subjects showed less than 0.7 in unaided distance visual acuity. In pinhole visual acuity test, 98% had an improved unaided pinhole visual acuity and most of them experienced an improvement and 2% had no change or dropped. The students with normal stereoscopic vision test were 85.6% and the students under normal range were 14.4%. In colour vision test, 7.9% of them were protanomaly and deuteranomaly and none of them had trichromasy and total color blindness. In cover test, it showed 30.2% of orthophoria, 8.2% of esophoria and 61.5% of exophoria, and none of them had strabismus.

  • PDF

The Study on the Property of The Heterophoria and Fusional Reserve in Adults in Jeon-buk Area (전북지역 성인의 사위와 융합여력 특성에 관한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun Mi;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.661-666
    • /
    • 2013
  • The aim of this study was to evaluate the property of heterophoria and fusional reserve in Adults in Jeon-buk Area. We examined the corrected visual acuity, corrected refractive error, heterophoria and fusional reserve of 116 healthy myopes aged from 20 to 44 old who had no strabismus no ocular and phyisical diseases. Using Von Graefe test of horizontal heterophoria Measurement, we measured orthophoria(26.7%), exophoria(52.5%) and esophoria(20.7%) for at near distance. The subjects who had exophoria of 0-6${\Delta}$ in the range of normal state was 38.8%, while the subjects who had exophoria in the range of abnormal state was 61.2%. Reducing fusional reserve was associated with increasing phoria. We found a relationship between asthenopia and fusional reserve of heterophoria and considered that fusional reserve must be examined when we preserve for a patient with heterophoria. Furthermore, Gradient method AC/A ratio was found 4.03 and its relationship to refractive error could not be determined.

Correlation of Near Stereoacuity and Phoria, and Refractive Error (근거리 입체시와 사위 및 굴절이상의 상관관계)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.67-73
    • /
    • 2015
  • Purpose: This study was investigated the relationship between the male and female of near stereoacuity and phoria, and was examined the correlations between near stereoacuity and phoria and refractive error. Methods: Adult 83 (male 36, female 47, mean age $21.09{\pm}1.74$(19~29) years old) target was examined after full correction of refractive error. Near stereoacuity was measured by using Titmus-fly Stereotest(Stereo Optical Co., Inc., Chicago, IL, USA), and RANDOT Stereotest (Stereo Optical Co., Inc., Chicago, IL, USA), phoria was measured by using modified torrington method, at distance 40 cm. Results: In near stereoacuity, male was better good than female, and there was no difference between male and female (p>0.05). In near phoria, female was more higher than male, and there was a significant difference between male and female (p<0.05). Near stereoacuity by Titmus-fly test and Randot test result respectively was $262.17{\pm}562.43$ sec (second of arc) $243.08{\pm}68.04$ sec in esophoria, $148.42{\pm}269.54$ sec, $107.40{\pm}263.74$ sec in orthophoria, $113.94{\pm}152.46$ sec, $79.70{\pm}136.83$ sec in exophoria, there was a no difference between three phoria groups (p>0.05), and was a high correlation between phoria and near stereoacity(r=0.68). In addition, near stereoacuity in the refractive error respectively was $80.00{\pm}571.43$ sec, $68.75{\pm}36.82$ sec in myopia, $133.57{\pm}224.15$ sec, $93.14{\pm}214.95$ sec in hyperopia, $511.20{\pm}855.00$ sec, $511.4{\pm}855.60$ sec, there was a significant difference between three phoria groups (p<0.05). when was classfiied near stersoacuity into degree of refractive error, near stersoacuity was best in emmetropia, and was reduced when refractive error was highest in high degree myopia, and hyperopia. Conclusions: Titmus-fly Stereotest and RANDOT Stereotest result, near stereoacuity of adults, when esophoria and high degree refractive error, was reduced, there was a relationship between near stereoacuity with phoria, and refractive error. In this both stereotests if was bad when near stereoacuity can expect a phoria and refractive error.