• Title/Summary/Keyword: Orthogonal Magnetic Field

Search Result 26, Processing Time 0.027 seconds

TD-CFIE Formulation for Transient Electromagnetic Scattering from 3-D Dielectric Objects

  • Lee, Young-Hwan;Jung, Baek-Ho;Sarkar, Tapan K.;Yuan, Mengtao;Ji, Zhong;Park, Seong-Ook
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.8-17
    • /
    • 2007
  • In this paper, we present a time domain combined field integral equation formulation (TD-CFIE) to analyze the transient electromagnetic response from dielectric objects. The solution method is based on the method of moments which involves separate spatial and temporal testing procedures. A set of the RWG functions is used for spatial expansion of the equivalent electric and magnetic current densities, and a combination of RWG and its orthogonal component is used for spatial testing. The time domain unknowns are approximated by a set of orthonormal basis functions derived from the Laguerre polynomials. These basis functions are also used for temporal testing. Use of this temporal expansion function characterizing the time variable makes it possible to handle the time derivative terms in the integral equation and decouples the space-time continuum in an analytic fashion. Numerical results computed by the proposed formulation are compared with the solutions of the frequency domain combined field integral equation.

  • PDF

An improved fuzzy c-means method based on multivariate skew-normal distribution for brain MR image segmentation

  • Guiyuan Zhu;Shengyang Liao;Tianming Zhan;Yunjie Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.8
    • /
    • pp.2082-2102
    • /
    • 2024
  • Accurate segmentation of magnetic resonance (MR) images is crucial for providing doctors with effective quantitative information for diagnosis. However, the presence of weak boundaries, intensity inhomogeneity, and noise in the images poses challenges for segmentation models to achieve optimal results. While deep learning models can offer relatively accurate results, the scarcity of labeled medical imaging data increases the risk of overfitting. To tackle this issue, this paper proposes a novel fuzzy c-means (FCM) model that integrates a deep learning approach. To address the limited accuracy of traditional FCM models, which employ Euclidean distance as a distance measure, we introduce a measurement function based on the skewed normal distribution. This function enables us to capture more precise information about the distribution of the image. Additionally, we construct a regularization term based on the Kullback-Leibler (KL) divergence of high-confidence deep learning results. This regularization term helps enhance the final segmentation accuracy of the model. Moreover, we incorporate orthogonal basis functions to estimate the bias field and integrate it into the improved FCM method. This integration allows our method to simultaneously segment the image and estimate the bias field. The experimental results on both simulated and real brain MR images demonstrate the robustness of our method, highlighting its superiority over other advanced segmentation algorithms.

SNU 1.5MV Van de Graaff Accelerator (IV) -Fabrication and Aberration Analysis of Magnetic Quadrupole Lens- (SNU 1.5MV 반데그라프 가속기 (IV) -자기 4극 렌즈의 제작과 수차의 분석-)

  • Bak, H.I.;Choi, B.H.;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 1986
  • A magnetic quadrupole doublet was fabricated for use at the pre-target position of SNU 1.5MV Van de Graaff accelerator and then its optical characteristics were measured and analysed. The physical dimensions are: pole length 180mm, aperture radius 25mm, pole tip radius 28.75mm. Material for poles and return yokes is carbon steel KS-SM40C. Coils have 480 turns per one pole and air-cooling is adopted. Applying the d.c. current 2.99$\pm$0.03A to the lens, and using the Hall probe, magnetic field elements $B_{\theta}$ , $B_{\gamma}$, were measured at the selected Points along each coordinate direction r,$\theta$, z. From the area integration and orthogonal polynomial fitting for the measured data, the magnetic Field gradient G=566.3$\pm$2.1 gauss/cm at lens center, the effective length L=208.3$\pm$1.44mm along the lens axis have been obtained. The harmonic contents were determined up to 20-pole from the generalized least squares fitting. The results indicate that sextupole/quadrupole is below 1.4$\pm$0.9% and all the other multipoles are below 0.5% in the region within 18mm radius at the center of lens.

  • PDF

A Design Of Cross-Shpaed CMOS Hall Plate And Offset, 1/f Noise Cancelation Technique Based Hall Sensor Signal Process System (십자형 CMOS 홀 플레이트 및 오프셋, 1/f 잡음 제거 기술 기반 자기센서 신호처리시스템 설계)

  • Hur, Yong-Ki;Jung, Won-Jae;Lee, Ji-Hun;Nam, Kyu-Hyun;Yoo, Dong-Gyun;Yoon, Sang-Gu;Min, Chang-Gi;Park, Jun-Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.152-159
    • /
    • 2016
  • This paper describes an offset and 1/f noise cancellation technique based hall sensor signal processor. The hall sensor outputs a hall voltage from the input magnetic field, which direction is orthogonal to hall plate. The two major elements to complete the hall sensor operation are: the one is a hall sensor to generate hall voltage from input magentic field, and the other one is a hall signal process system to cancel the offset and 1/f noise of hall signal. The proposed hall sensor splits the hall signal and unwanted signals(i.e. offset and 1/f noise) using a spinning current biasing technique and chopper stabilizer. The hall signal converted to 100 kHz and unwanted signals stay around DC frequency pass through chopper stabilizer. The unwanted signals are bloked by highpass filter which, 60 kHz cut off freqyency. Therefore only pure hall signal is enter the ADC(analog to dogital converter) for digitalize. The hall signal and unwanted signal at the output of an amplifer and highpass filter, which increase the power level of hall signal and cancel the unwanted signals are -53.9 dBm @ 100 kHz and -101.3 dBm @ 10 kHz. The ADC output of hall sensor signal process system has -5.0 dBm hall signal at 100 kHz frequency and -55.0 dBm unwanted signals at 10 kHz frequency.

Developments of the Wide Wavelength Range Polarimeter of the Domeless Solar Telescope at the Hida Observatory

  • Anan, Tetsu;Ichimoto, Kiyoshi;Oi, Akihito;Ueno, Satoru;Kimura, Goichi;Nakatani, Yoshikazu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • We are developing a new universal spectropolarimeter on the Domeless Solar Telescope (DST) at the Hida Observatory to realize precise spectropolarimetric observations in a wide range of wavelength in visible and near infrared. The system aims to open a new window of plasma diagnostics by using Zeeman effect, Hanle effect, Stark effect, impact polarization, and atomic polarization for measuring the external magnetic field, electric field, or an anisotropy in the excitation of the atoms. The polarimeter is a successor of formerly developed polarimeter on DST, which make possible to observe a polarization in a photospheric spectral line with polarimetric accuracy of 10-2 (Kiyohara et al. 2004). The new system consists of a 60cm aperture vacuum telescope, a high dispersion vacuum spectrograph, polarization modulator / analyzer composed of a rotating waveplate whose retardation is constant for a wide range of wavelength and Wallaston prism, and a fast and large format CCD camera or IR camera. Spectral images in both orthogonal polarizations are taken simultaneously with a frame rate of ~20Hz while the waveplate rotates continuously in a rate of 1rev./sec. Thus It takes 5 ~ 60 sec to observe polarization with accuracy of 10-3 in a wide wavelength range (400 - 1100nm). We also examined a polarimetric model of the telescope with accuracy of 10-3 to calibrate instrumental polarization on some wavelengths. In this talk, I will focus on the performance of the instrument.

  • PDF

Analysis of in vitro 2D-COSY on Human Brain Metabolites for Molecular Stereochemistry

  • Kim, Sang-Young;Woo, Dong-Cheol;Bang, Eun-Jung;Kim, Sang-Soo;Lim, Hyang-Sook;Choi, Chi-Bong;Choe, Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.12 no.1
    • /
    • pp.14-25
    • /
    • 2008
  • To investigate the 3-bond connectivity of human brain metabolites by scalar coupling interaction through 2D-correlation spectroscopy (COSY) techniques using high field NMR spectroscopy. All NMR experiments were performed at 298K on Unity Inova 500 or 600 (Varian Inc.) equipped with a triple resonance probe head with z-shield gradient. Human brain metabolites were prepared with 10% $D_2O$. Two dimensional 2D COSY spectra were acquired with 4096 complex data points in $t_2$ and 128 or 256 increments in $t_1$ dimension. The spectral width was 9615.4 Hz and solvent suppression was achieved using presaturation using low power irradiation of the water resonance during 2s of relaxation delay. NMR data were processed using VNMRJ (Varian Instrument) software and all the chemical shifts were referenced to the methyl resonance of N-acetyl aspartate (NAA) peak at 2.0 ppm. Total 10 metabolites such as N-acetyl aspartate (NAA), creatine (Cr), choline (Cho), glutamine (Gln), glutamate (Glu), myo-inositol (Ins), lactate (Lac), taurine (Tau), ${\gamma}$-aminobutyricacid (GABA), alanine (Ala) were included for major target metabolites. Symmetrical 2D-COSY spectra were successfully acquired. Total 14 COSY cross peaks were observed even though there were parallel/orthogonal noisy peaks induced by water suppression. Except for Cr, all of human brain metabolites produced COSY cross peaks. The spectra of NAA methyl proton at 2.02 ppm and Glu methylene proton ($CH_2(3)$) at 2.11 ppm and Gln methylene proton ($CH_2(3)$) at 2.14 ppm were overlapped in the similar resonance frequency between 2.00 ppm and 2.15 ppm. The present study demonstrated that in vitro 2D-COSY represented the 3-bond connectivity of human brain metabolites by scalar coupling interaction. This study could aid in better understanding the interactions between human brain metabolites in vivo 2D-COSY study. Also it would be helpful to determine the molecular stereochemistry in vivo by using two-dimensional MR spectroscopy.