• Title/Summary/Keyword: Orthogonal Factor

Search Result 264, Processing Time 0.019 seconds

The Preference Analysis of Adults on the Forest Therapy Program with regard to Demographic Characteristics (인구통계학적 특성에 따른 성인 대상별 산림치유 프로그램 선호도 분석)

  • Kim, Youn-Hee;Kim, Eun-Jin;Kim, Dong-Jun;Yeoun, Pyung-Sik;Choi, Byung-Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.1
    • /
    • pp.150-161
    • /
    • 2015
  • The purpose of this study was to obtain the basic data for the effective development and operation of forest healing by analysing the preference of adults on the forest therapy program. The survey of 516 normal adults on the forest therapy program was conducted. Using SPSS 21.0 Program, data analysis of descriptive statistics and correlation analysis of each program confirmed number of covariate, and so we conducted a factor analysis to short meaningful data. And then we looked at the forest healing program preference difference according to demographic characteristics(sex, age, residence, occupation) through reliability analysis, frequency analysis, T-test, analysis of variance(ANOVA). Facter analysis was performed by use of the VariMax orthogonal rotation factor analysis to abbreviate 37 forest therapy program. Through this, the program has been reduced such as 7 program group(1: psychology-based treatment, 2: teaching and counselling-based treatment, 3: camping and forest bath-based treatment, 4: diet-based treatment, 5: nature and plant-based treatment, 6: meditation-based treatment, 7: respiration and yoga-based treatment) and 7 independent programs(1: sleeping in the forest, 2: vision quest, 3: soaking in water, 4: walking wearing shoes, 5: viewing the forest, 6: mountaineering, 7: athletics in the forest). With this criterion, the forest therapy program difference in accordance with sex, age, residence, occupation has been investigated. First, it was verified that there was a significant difference between male and female in the group of such as psychology-based treatment, diet-based treatment, mountaineering. Second, there appeared a significant difference in groups such as teaching and counselling-based treatment, camping and forest bath-based treatment, nature and plant-based treatment, respiration and yoga-based treatment, athletics in the forest. Third, according to the residence, there appeared a significant difference in groups such as psychology-based treatment, teaching and counselling-based treatment, diet-based treatment, nature and plant-based treatment, meditation-based treatment, vision quest, mountaineering, athletics in the forest. Fourth, according to the occupation, there appeared a significant difference in groups such as nature and plant-based treatment, medication-based treatment, vision quest, walking wearing shoes, viewing the forest, mountaineering. As shown before, it seems to be necessary that we should be mindful of this investigation which shows variety of preference of adults on the forest therapy program according to demographic characteristics. We expect the results of this study to be utilized as basic data for the development of forest therapy program targeting on adults.

A Study on Damage factor Analysis of Slope Anchor based on 3D Numerical Model Combining UAS Image and Terrestrial LiDAR (UAS 영상 및 지상 LiDAR 조합한 3D 수치모형 기반 비탈면 앵커의 손상인자 분석에 관한 연구)

  • Lee, Chul-Hee;Lee, Jong-Hyun;Kim, Dal-Joo;Kang, Joon-Oh;Kwon, Young-Hun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.7
    • /
    • pp.5-24
    • /
    • 2022
  • The current performance evaluation of slope anchors qualitatively determines the physical bonding between the anchor head and ground as well as cracks or breakage of the anchor head. However, such performance evaluation does not measure these primary factors quantitatively. Therefore, the time-dependent management of the anchors is almost impossible. This study is an evaluation of the 3D numerical model by SfM which combines UAS images with terrestrial LiDAR to collect numerical data on the damage factors. It also utilizes the data for the quantitative maintenance of the anchor system once it is installed on slopes. The UAS 3D model, which often shows relatively low precision in the z-coordinate for vertical objects such as slopes, is combined with terrestrial LiDAR scan data to improve the accuracy of the z-coordinate measurement. After validating the system, a field test is conducted with ten anchors installed on a slope with arbitrarily damaged heads. The damages (such as cracks, breakages, and rotational displacements) are detected and numerically evaluated through the orthogonal projection of the measurement system. The results show that the introduced system at the resolution of 8K can detect cracks less than 0.3 mm in any aperture with an error range of 0.05 mm. Also, the system can successfully detect the volume of the damaged part, showing that the maximum damage area of the anchor head was within 3% of the original design guideline. Originally, the ground adhesion to the anchor head, where the z-coordinate is highly relevant, was almost impossible to measure with the UAS 3D numerical model alone because of its blind spots. However, by applying the combined system, elevation differences between the anchor bottom and the irregular ground surface was identified so that the average value at 20 various locations was calculated for the ground adhesion. Additionally, rotation angle and displacement of the anchor head less than 1" were detected. From the observations, the validity of the 3D numerical model can obtain quantitative data on anchor damage. Such data collection can potentially create a database that could be used as a fundamental resource for quantitative anchor damage evaluation in the future.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Analysis of Optimal Resolution and Number of GCP Chips for Precision Sensor Modeling Efficiency in Satellite Images (농림위성영상 정밀센서모델링 효율성 재고를 위한 최적의 해상도 및 지상기준점 칩 개수 분석)

  • Choi, Hyeon-Gyeong;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1445-1462
    • /
    • 2022
  • Compact Advanced Satellite 500-4 (CAS500-4), which is scheduled to be launched in 2025, is a mid-resolution satellite with a 5 m resolution developed for wide-area agriculture and forest observation. To utilize satellite images, it is important to establish a precision sensor model and establish accurate geometric information. Previous research reported that a precision sensor model could be automatically established through the process of matching ground control point (GCP) chips and satellite images. Therefore, to improve the geometric accuracy of satellite images, it is necessary to improve the GCP chip matching performance. This paper proposes an improved GCP chip matching scheme for improved precision sensor modeling of mid-resolution satellite images. When using high-resolution GCP chips for matching against mid-resolution satellite images, there are two major issues: handling the resolution difference between GCP chips and satellite images and finding the optimal quantity of GCP chips. To solve these issues, this study compared and analyzed chip matching performances according to various satellite image upsampling factors and various number of chips. RapidEye images with a resolution of 5m were used as mid-resolution satellite images. GCP chips were prepared from aerial orthographic images with a resolution of 0.25 m and satellite orthogonal images with a resolution of 0.5 m. Accuracy analysis was performed using manually extracted reference points. Experiment results show that upsampling factor of two and three significantly improved sensor model accuracy. They also show that the accuracy was maintained with reduced number of GCP chips of around 100. The results of the study confirmed the possibility of applying high-resolution GCP chips for automated precision sensor modeling of mid-resolution satellite images with improved accuracy. It is expected that the results of this study can be used to establish a precise sensor model for CAS500-4.