• Title/Summary/Keyword: Orthodontic retainer

Search Result 28, Processing Time 0.018 seconds

Discomfort caused by the circumferential comfortable retainer (CCR) as a removable maxillary retainer (상악 가철식 보정장치인 circumferential comfortable retainer (CCR)에 대한 불편감 평가)

  • Choi, Jin-Hugh;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.325-333
    • /
    • 2010
  • Objective: The aim of this study was to illustrate the circumferential comfortable retainer (CCR) as a removable maxillary retainer with good potential patient compliance and to evaluate the discomfort of the retainers including distorted speech, gagging sensation and appliance discomfort. Methods: Sixty-six orthodontic patients (male, 23; female, 43; mean age, $23.42{\pm}10.19$ years) who received orthodontic treatment with fixed orthodontic appliances were randomly assigned to two groups after debonding, a conventional wraparound retainer (CWR) group that fully covers the palate with an acrylic plate and a highly polished surface, and a circumferential comfortable retainer (CCR) group which has a horseshoe shaped base plate with three folds on the anterior region. A questionnaire that had a visual analog scale (VAS) which consists of a 100-mm horizontal line with 2 end-points labeled "no discomfort" on the left and "worst discomfort" on the right, with regard to distorted speech, gagging sensation and discomfort, was administered to patients after 4 weeks of retainer wear. The Mann-Whitney test was used to test the hypothesis that there was no difference between the two retainers. Results: Comparing distorted speech and discomfort, the CCR group significantly had lower values than the CWR group ($p$ < 0.05). Comparing gagging sensation, the CCR group had lower values than the CWR group but there were no statistically significant differences between groups ($p$ = 0.146). Conclusions: In conclusion, the results suggest that the circumferential comfortable retainer (CCR) might facilitate patient compliance and thereby improve the maintenance of the fixed orthodontic treatment outcome.

A survey on retention practice among orthodontists in Malaysia

  • Rahman, Norma Ab;Low, Tze Fui;Idris, Nur Shaheera
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.36-41
    • /
    • 2016
  • Objective: The aim of this study was to evaluate retention practices commonly employed by orthodontists. The objectives were to identify the types of retainer frequently used and to investigate the variations in retention practice. Methods: A total of 97 orthodontists were randomly selected, and a questionnaire consisting of 25 multiple-choice questions sent to them by mail. Upon receiving of the completed questionnaires, the data were statistically analyzed. Results: A total of 32 responses were received; among these, 59.4% of orthodontists' practiced is in a government setting and 40.6% were in private practice. A vacuum-formed retainer was the most commonly used removable retainer for both maxillary (46.9%) and mandibular (46.9%) arches, followed by a Hawley retainer (maxilla, 43.8%; mandible, 37.5%), and a fixed retainer (maxilla, 3.1%; mandible, 9.4%). Of the responding orthodontists, 78.1% prescribed full-time wear (more than 20 h per day) for a duration of 3-9 months for a maxillary arch, compared to 71.9% for the mandibular arch. Only 18.8% of the orthodontists prescribed part-time wear of the retainer for the maxillary arch, compared to 21.9% for the mandibular arch. The majority of orthodontists did not instruct their patients to stop wearing removable retainers (71.9%) or fixed retainers (66.8%) at any specific time and they preferred their patients to continue wearing retainers. Conclusions: Vacuum-formed retainers are the most commonly used retainers among orthodontists. The majority of orthodontists prescribed full-time wear for more than 20 h per day with a duration of 3-9 months and preferred indefinite use of the retainer.

A new type of clear orthodontic retainer incorporating multi-layer hybrid materials

  • Ahn, Hyo-Won;Kim, Kyung A;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.45 no.5
    • /
    • pp.268-272
    • /
    • 2015
  • Clear thermoplastic retainers have been widely used in daily orthodontics; however, they have inherent limitations associated with thermoplastic polymer materials such as dimensional instability, low strength, and poor wear resistance. To solve these problems, we developed a new type of clear orthodontic retainer that incorporates multi-layer hybrid materials. It consists of three layers; an outer polyethylenterephthalate glycol modified (PETG) hard-type polymer, a middle thermoplastic polyurethane (TPU) soft-type polymer, and an inner reinforced resin core. The resin core improves wear resistance and mechanical strength, which prevent unwanted distortion of the bucco-palatal wall of the retainer. The TPU layer absorbs impact and the PETG layer has good formability, optical qualities, fatigue resistance, and dimensional stability, which contributes to increased support from the mandibular dentition, and helps maintain the archform. This new type of vacuum-formed retainer showed improved mechanical strength and rate of water absorption.

Non-surgical treatment and retention of open bite in adult patients with orthodontic mini-implants (성인 환자에서 구치부 압하를 통한 개방교합의 치료와 유지)

  • Moon, Cheol-Hyun;Lee, Joo-Sin;Lee, Hyun-Sun;Choi, Jin-Hugh
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.402-419
    • /
    • 2009
  • Successful treatment of the non-growing patient with an open bite of either dental skeletal pattern often presents a difficult challenge. The morphologic pattern in anterior open bite is characterized by longer vertical dimensions, an increase in development of the maxillary posterior dento-alveolar structure and a steep mandibular plane. In such cases, molar intrusion would be a good remedy for treatment. This article reports the successful treatment and retention of two anterior open-bite cases. We used orthodontic mini-implants for treatment and a circumferential retainer with posterior bite block or skeletal fixed retainer for retention. The diagnostic criteria and mechanics for appropriate treatment are discussed. Our results suggest that open bite can be reduced successfully with intrusion of molars using orthodontic mini-implants (OMI) without orthognathic surgery, and that circumferential retainer with posterior bite block and skeletal fixed retainer are effective for retention.

Effects of a new type of clear overlay retainer on occlusal contacts

  • Kim, Kyoung Yeon;Ahn, Hyo-Won;Kim, Seong-Hun;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.47 no.3
    • /
    • pp.207-212
    • /
    • 2017
  • The popularity of clear overlay retainers (CORs) has increased recently because of their advantages such as better esthetics, cost effectiveness, easy fabrication, and good compliance. However, a deficiency in posterior occlusal settling is a reported limitation of CORs. The aim of this study was to evaluate the posterior occlusal contact changes in a new type of clear orthodontic retainer called Oral-treaper (OTP), which consists of three layers and has stronger mechanical characteristics than do conventional retainers. Three patients who completed fixed orthodontic treatment received OTP as a removable retainer. Cast models were fabricated after the removal of fixed appliances (T1) and after 4 to 11 months of using the retainers (T2). We evaluated all the cast models to compare the post-orthodontic settling pattern during the use of the OTPs. The depth of occlusal contacts was evaluated using color maps. The OTP did not prevent vertical settling in all patients but resulted in an improvement in posterior occlusal contact points.

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

A Clinical Study on the Etched Resin Bonded Retainer for Fixed Bridgework (Etched Metal Resin Bonded Retainer에 관한 임상적 연구)

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.21 no.5 s.168
    • /
    • pp.395-402
    • /
    • 1983
  • The purpose of this study was to apply the etched metal ceramometal retainer using a composite resin and acid-etch procedure with minimal tooth reduction of abutments for the replacement of one missing anterior or posterior tooth. Author obtained the following conclusions. 1. conservation of tooth structure and minimal chair time and patient expense were the primary advantages of etched metal retainer. 2. This fixed partial denture permitted good esthetic results. 3. This retainer was successfully applied for the replacement of one missing anterior or posterior tooth. 4. Proper retainer etching ws an important procedure. 5. Etched castings could be applied to periodontal splinting and post orthodontic fixation.

  • PDF

Clinical factors affecting the longevity of fixed retainers and the influence of fixed retainers on periodontal health in periodontitis patients: a retrospective study

  • Han, Ji-Young;Park, Seo Hee;Kim, Joohyung;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.3
    • /
    • pp.163-178
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate clinical factors affecting the longevity of fixed retainers and the influence of fixed retainers on periodontal health in periodontitis patients. Methods: In total, 52 patients with at least 2 years of follow-up after periodontal and orthodontic treatment were included in this study. After scaling and root planing, orthodontic treatment with fixed appliances or clear aligners was performed. Fixed retainers with twist-flex stainless steel wires were bonded to the palatal or lingual sides of anterior teeth. Changes in clinical parameters, including the plaque index, gingival index, calculus index (CI), probing pocket depth, and radiographic bone levels, were evaluated before bonding of fixed retainers and at a 12-month follow-up. Cumulative survival rates (CSRs) for retainer failure were evaluated according to sex, site, CI, stage of periodontitis, and the severity of the irregularity with the log-rank test and hazard ratios (HRs). Results: Twelve months after bonding of fixed retainers, improvements were observed in all clinical parameters except CI and radiographic bone gain. The overall CSR of the retainers with a CI <1 at the 12-month follow-up after bonding of fixed retainers was significantly higher than that of the retainers with a CI ≥1 at the 12-month follow-up (log-rank test; P<0.001). Patients with stage III (grade B or C) periodontitis had a higher multivariate HR for retainer failure (5.4; 95% confidence interval, 1.22-23.91; P=0.026) than patients with stage I (grade A or B) periodontitis. Conclusions: Although fixed retainers were bonded in periodontitis patients, periodontal health was well maintained if supportive periodontal treatment with repeated oral hygiene education was provided. Nonetheless, fixed retainer failure occurred more frequently in patients who had stage III (grade B or C) periodontitis or a CI ≥1 at 12-month follow-up after bonding of fixed retainers.

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

  • Uysal, Tancan;Sakin, Caglar;AI-Qunaian, Talal
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite.

A Study of shear bond strength of bonded retainer according to the bonding method and type of wires (접착방법 및 multistranded wire의 종류에 따른 접착식 보정장치의 전단접착강도에 관한 연구)

  • Lee, Hyoung-Cheol;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.143-153
    • /
    • 2002
  • The bonded orthodontic retainer constructed from composite and multistrand orthodontic wire provides an esthetic and efficient system for maintained retention. This study was designed to measure shear bond strength of bonded retainers and to suggest a optimal combination of a multistrand wire and bonding method used when bonded retainer was fabricated. 160 sound maxillary and mandibular premolars were used for 80 test samples. After Uniformizing bonding area, length of wire, and thickness of composite, multistrand wire was bonded to fabricated a bonded retainer by direct or indirect bonding method. Shear bond strength and extension length of each sample were measured by a universal testing machine. The results of this study were as follows : 1. In vitro shear bond testing found 6-stranded, 0.0155 inch wires to have the largest shear bond strength and 3-stranded, 0.0195 inch wires to have the least shear bond strength. But, These difference was not statistically significant(p<0.05). 2. In vitro extension testing found 3-stranded, 0.0155 inch wires to have the largest extension length and 3-stranded, 0.0195 inch wires to have the least extension length(p<0.05). The larger diameter wire was used, the larger extension length was shown. But, the strand of wire is not related to the extension length of wire. 3. In comparison with direct bonding method, larger shear bond strength and extension length was shown in indirect bonding method(p<0.05).