• Title/Summary/Keyword: Orthodontic miniscrews

Search Result 45, Processing Time 0.027 seconds

Indirect palatal skeletal anchorage (PSA) for treatment of skeletal Class I bialveolar protrusion (Indirect palatal skeletal anchorage (PSA)를 이용한 골격성 I급 양악 치성 전돌 환자의 치험례)

  • Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.458-464
    • /
    • 2004
  • Anchorage plays an important role in orthodontic treatment especially in the maxillary arch. In spite of many efforts for anchorage control. it was difficult for clinicians to predict the result of treatment because most of the treatment necessitated an absolute compliance of patients, But recently, skeletal anchorage has been used widely because it does not necessitate patient compliance but produces absolute anchorage. In addition titanium miniscrews have several advantages such as ease of insertion and removal. possible immediate leading and use in limited implantation spaces. In this case, a skeletal Class I bialveolar protrusion Patient was treated with standard edgewise mechanics using indirect active P.S.A. (palatal skeletal anchorage). The miniscrews in the paramedian area of the hard palate provided anchorage for retraction of the upper anterior teeth and remained firm and stable throughout treatment This indicates that the PSA can be used to reinforce anchorage for orthodontic treatment in the maxillary arch Consequently, this new approach can help effective tooth movement without patient compliance, when used with various transpalatal arch systems.

Which anchorage device is the best during retraction of anterior teeth? An overview of systematic reviews

  • Yassir, Yassir A.;Nabbat, Sarah A.;McIntyre, Grant T.;Bearn, David R.
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.220-235
    • /
    • 2022
  • Objective: To evaluate the available evidence regarding the clinical effectiveness of different types of anchorage devices. Methods: A comprehensive literature search of different electronic databases was conducted for systematic reviews investigating different anchorage methods published up to April 15, 2021. Any ongoing systematic reviews were searched using PROSPERO, and a grey literature search was undertaken using Google Scholar and OpenGrey. No language restriction was applied. Screening, quality assessment, and data extraction were performed independently by two authors. Information was categorized and narratively synthesized for the key findings from moderate- and high-quality reviews. Results: Fourteen systematic reviews were included (11 were of moderate/high quality). Skeletal anchorage with miniscrews was associated with less anchorage loss (and sometimes with anchorage gain). Similarly, skeletal anchorage was more effective in retracting anterior teeth and intruding incisors and molars, resulting in minor vertical skeletal changes and improvements in the soft tissue profile. However, insufficient evidence was obtained for the preference of any anchorage method in terms of the duration of treatment, number of appointments, quality of treatment, patient perception, or adverse effects. The effectiveness of skeletal anchorage can be enhanced when: directly loaded, used in the mandible rather than the maxilla, used buccally rather than palatally, using dual rather than single miniscrews, used for en-masse retraction, and in adults. Conclusions: The level of evidence regarding anchorage effectiveness is moderate. Nevertheless, compared to conventional anchorage, skeletal anchorage can be used with more anchorage preservation. Further high-quality randomized clinical trials are required to confirm these findings.

3-D FEA on the intrusion of mandibular anterior segment using orthodontic miniscrews (교정용 미니스크류를 이용한 하악 전치 함입 시 변위양상의 3차원 유한요소분석)

  • Park, Hyun-Kyung;Sung, Eui-Hyang;Cho, Young-Soo;Mo, Sung-Seo;Chun, Youn-Sic;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.384-398
    • /
    • 2011
  • Objective: The purpose of this study was to analyze the stress distribution and the displacement pattern of mandibular anterior teeth under various intrusive force vectors according to the position of orthodontic miniscrews and hooks, using three-dimensional finite element analysis. Methods: A three-dimensional finite element model was constructed to simulate mandibular teeth, periodontal ligament, and alveolar bone. The displacement of individual tooth on three-dimensional planes and the von Mises stress distribution were compared when various intrusion force vectors were applied. Results: Intrusive forces applied to 4 mandibular anterior teeth largely resulted in remarkable labial tipping of the segment according to the miniscrew position. All 6 mandibular anterior teeth were labially tipped and the stress concentrated on the labiogingival area by intrusive force from miniscrews placed mesial to the canine. The distointrusive force vector led to pure intrusion and the stress was evenly distributed in the whole periodontal ligament when the hook was placed between the central and lateral incisors and the miniscrew was placed distal to the canine. Conclusions: Within the limits of this study, it can be concluded that predictable pure intrusion of the 6 anterior teeth segment may be accomplished using miniscrews placed distal to the canine and hooks located between the central and lateral incisors.

Consideration of maxillary sinus bone thickness when installing miniscrews (미니스크류 식립 시 상악동의 골두께에 대한 고려)

  • Kim, Do-Hyun;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.354-361
    • /
    • 2009
  • Objective: Miniscrews are widely used in orthodontic treatment for the purpose of anchorage control. Maximum anchorage can be acquired by the use of miniscrews. Maxillary miniscrew has many clinical advantage for orthodontic treatment. Maxillary sinus, tooth root can be an obstacle for maxillary miniscrew installation. The purpose of this study was to find the safest area and direction of miniscrew insertion in consideration of the maxillary sinus. Methods: The maxillary sinus area of 40 patients (20 male, 20 female) was measured using 3D computed tomography and 3D reconstruction program. Results: The maxillary sinus floor was located most inferiorly between the 1st molar and 2nd molar and located most superiorly between the 1st premolar and 2nd premolar. Buccal bone thickness from the maxillary sinus is significantly thicker between the 1st molar and 2nd molar and significantly thinner between the 1st premolar and 2nd premolar. The area between the 1st premolar and 2nd premolar has a significantly longer vertical distance from CEJ to sinus in consideration of buccal bone thickness. Conclusions: Considering maxillary bone thickness, the posterior area has advantages over the anterior area for installing miniscrews safely and preventing perforation.

Nonsurgical correction of a severe anterior deep overbite accompanied by a gummy smile and posterior scissor bite using a miniscrew-assisted straight-wire technique in an adult high-angle case

  • Wang, Xue-Dong;Zhang, Jie-Ni;Liu, Da-Wei;Lei, Fei-fei;Zhou, Yan-Heng
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.253-265
    • /
    • 2016
  • In the present report, we describe the successful use of miniscrews to achieve vertical control in combination with the conventional sliding MBT$^{TM}$ straight-wire technique for the treatment of a 26-year-old Chinese woman with a very high mandibular plane angle, deep overbite, retrognathic mandible with backward rotation, prognathic maxilla, and gummy smile. The patient exhibited skeletal Class II malocclusion. Orthodontic miniscrews were placed in the maxillary anterior and posterior segments to provide rigid anchorage and vertical control through intrusion of the incisors and molars. Intrusion and torque control of the maxillary incisors relieved the deep overbite and corrected the gummy smile, while intrusion of the maxillary molars aided in counterclockwise rotation of the mandibular plane, which consequently resulted in an improved facial profile. After 3.5 years of retention, we observed a stable, well-aligned dentition with ideal intercuspation and more harmonious facial contours. Thus, we were able to achieve a satisfactory occlusion, a significantly improved facial profile, and an attractive smile for this patient. The findings from this case suggest that nonsurgical correction using miniscrew anchorage is an effective approach for camouflage treatment of high-angle cases with skeletal Class II malocclusion.

The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V)

  • Huang, Gui-Yue;Jiang, Heng Bo;Cha, Jung-Yul;Kim, Kwang-Mahn;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.306-312
    • /
    • 2017
  • Objective: The purpose of this study was to examine the effect of commercially available fluoride-containing oral rinses on the corrosion behavior of titanium alloys, which are the main components of orthodontic miniscrews. Methods: Four commercially available oral rinses (solution A, pH 4.46/260 ppm fluoride; solution B, pH 4.41/178 ppm fluoride; solution C, pH 6.30/117 ppm fluoride; and solution D, pH 4.17/3.92 ppm fluoride) were tested on titanium alloy (Ti-6Al-4V) circular plates, and saline was used as the control. The open-circuit potential and potentiodynamic polarization of these materials were measured. Thereafter, all samples were evaluated under a field-emission scanning electron microscope. Results: Among the tested oral rinses, except solution D, the more the fluoride content was, the greater was the corrosion potential downtrend; the corrosion resistance of the titanium alloy sample was also lowered significantly (p < 0.05). Field-emission scanning electron microscopic analysis of the surface morphology of the titanium alloy samples revealed that all samples had some defects, crevices, or pitting after exposure to the oral rinses than before treatment. In particular, the samples in solution A showed the most changes. Conclusions: Commercially available oral rinses having a high fluoride concentration and a low pH may reduce the corrosion resistance of titanium alloys used in dental appliances such as orthodontic titanium miniscrews and brackets.

Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysis

  • Jeong, Do-Min;Oh, Song Hee;Choo, HyeRan;Choi, Yong-Suk;Kim, Seong-Hun;Lee, Jin-Suk;Hwang, Eui-Hwan
    • The korean journal of orthodontics
    • /
    • v.51 no.4
    • /
    • pp.231-240
    • /
    • 2021
  • Objective: This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area. Methods: Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses. Results: The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area. Conclusions: Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal arches

  • Miresmaeili, Amirfarhang;Sajedi, Ahmad;Moghimbeigi, Abbas;Farhadian, Nasrin
    • The korean journal of orthodontics
    • /
    • v.45 no.5
    • /
    • pp.236-244
    • /
    • 2015
  • Objective: The aim of this study was to investigate three-dimensional molar displacement after distalization via miniscrews and a horizontal modification of the trans-palatal-arch (TPA). Methods: The subjects in this clinical trial were 26 Class II patients. After the preparation of a complete set of diagnostic records, miniscrews were inserted between the maxillary 2nd premolar and 1st molar on the palatal side. Elastic modules connected to the TPA exerting an average force of 150-200 g/side parallel to the occlusal plane were applied. Cone-beam computed tomography was utilized to evaluate the position of the miniscrews relative to the adjacent teeth and maxillary sinus, and the direction of force relative to molar furcation. The distances from the central point of the incisive papilla to the mesiopalatal cusps of the 1st maxillary molars and the distances between the mesiopalatal cusps of the left and right molars were measured to evaluate displacement of the maxillary molars on the horizontal plane. Interocclusal space was used to evaluate vertical changes. Results: Mean maxillary 1st molar distalization was $2.3{\pm}1.1mm$, at a rate of $0.4{\pm}0.2mm/month$, and rotation was not significant. Intermolar width increased by $2.9{\pm}1.8mm$. Molars were intruded relative to the neighboring teeth, from 0.1 to 0.8 mm. Conclusions: Distalization of molars was possible without extrusion, using the appliance investigated. The intrusive component of force reduced the rate of distal movement.

THE EFFICIENCY OF SAS USED RETRACTION OF THE ANTERIOR TEETH ON ORTHODONTIC TREATMENT (교정치료시 전치부 후방견인에 이용하는 SAS의 효율성)

  • Woo, Soon-Seop;Jeong, Soon-Tai;Huh, Young-Sung;Hwang, Kyung-Gyun;Yoo, Im-Hag;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.245-248
    • /
    • 2003
  • The retraction of anterior teeth could be performed more easier by inducing of skeletal anchorage system rather than by conventional method on orthodontic treatment. But, we wonder how effective the system draws well without anchorage loss and draws anterior teeth aside posteriorly, and if the system can reduce the time, in comparison with the anchorage of posterior teeth. For that reason we have studied on the subject of patients, who were required the maximum anchorage on orthodontic treatment and the cases without crowding. The subjects of the experimental group are 35 areas of 20 people who were inserted miniscrews after Mx or Mn 1st premolar extracted. Also, the subjects of the control group are 81 areas of 45 people who were not inserted miniscrews. Compared the anchorage loss of experimental group with control one, we could get the result that the anchorage loss of experimental group is $1.034{\pm}0.891mm$ and control group is $2.790{\pm}1.882mm$(P<0.01). Compared the space closing time of experimental group with control one, we could get the result that the space closing time of experimental group is $369.40{\pm}110.81$days and control group is $406.56{\pm}231.63$days. But the result of comparing space closing time has no significance in statistics. We recognized that the experimental group is more faster than the control group in the canine retraction velocity from the result ; the speed of a experimental group has as much as $0.60{\pm}0.23mm/30days$ while the speed of a control group has $0.44{\pm}0.35mm/30days$(P<0.05). So, we could convince that orthodontic miniscrew is used effectively in the cases required the maximum anchorage.