• Title/Summary/Keyword: Orthodontic appliances

Search Result 165, Processing Time 0.019 seconds

ERUPTION GUIDANCE FOR TOOTH GERM OF PREMOLAR DISPLACED BY INFRAOCCLUDED UPPER DECIDUOUS MOLAR (저위교합된 상악 유구치에 의해 변위된 소구치 치배의 맹출유도)

  • Jung, Jung-Hwa;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.390-396
    • /
    • 2012
  • Infraocclusion is defined as tooth whose relative occlusal movement was blocked during the period of active eruption due to ankylosis and so on. Then infraoccluded tooth remains under the occlusal plane composed by adjacent structures showing normal eruption patterns. Untreated infraocclusion may cause: prolonged retention of infraoccluded teeth; extrusion of apposed teeth; destruction of periodontal tissues by occlusal force and food packing; increased sensitivity for dental caries; and disturbances on eruption pathway of succedaneous teeth. Therefore, periodic check-ups and proper treatments are required. There are many treatment options on infraoccluded deciduous molars such as periodic observation, conservative method, restoration and space regaining with extraction of the teeth. The choice of treatment may depend on the presence of succedaneous teeth, time of diagnosis and degree of infraocclusion. In this case report, three patients showing displacement of the second premolars due to infraocclusion of upper second primary molars, were treated by means of space regaining with removable orthodontic appliances and extraction of ankylosed primary molars. All malpositioned permanent premolars in the 3 cases showed ordinary eruption pathways after treatment.

Effect of Presurgical Nasoalveolar Molding in Unilateral Cleft Lip and Palate Infants (편측성 구순구개열 신생아에 대한 술전비치조정형장치의 효과)

  • Kim, Jin-Sun;Kim, Young-Jin;Nam, Soon-Hyeun;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.209-215
    • /
    • 2013
  • Cleft lip and palate, the most common craniofacial anomalies, are severe congenital defects that have an incidence of 0.28 to 3.74 per 1000 live births. Although there has been great improvement in the field of cleft surgery, surgical approach cannot be the single solution to resolve the various problems encountered in patients with cleft lip and palate. The concept of presurgical infant orthopedics (PSIO) for gradual closure of the cleft gap and simplified surgical performance was first introduced by McNeil in 1950. Recently, there are many attempts not only to approximate the alveolar segments but also to reshape the nasal cartilage. Three infants with unilateral cleft lip and palate were referred from the department of Plastic Surgery for presurgical nasoalveolar molding (PNAM). Maxillary appliances using resin with orthodontic wire were fabricated. Then these appliance was applied until patients underwent lip surgery. In all cases, the patients could wear the appliance all day since they were able to eat even with the appliance on, This resulted in significant improvements in the nasal symmetry were found. Our appliance, namely K-NAM, extends the wearing time within the limited period and as a result it is expected to maximize the treatment effects. Used properly, this appliance would play a major role in enhancing nasal symmetry with satisfactory results.

Analysis of PDL Fibroblast Change During Mechanical Stimuli in the Rats (기계적 자극에 대한 백서 치주인대 섬유아세포의 변화)

  • Kim, Tae-Gyun;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.277-285
    • /
    • 2001
  • Periodontal disease is characterized by inflammation and subsequent loss and/or damage to tooth-supporting tissues such as bone, cementum,and periodontal ligament. Periodontal ligament and cementum are the key tissues in the initial process of regeneration following periodontal disease. Therefore, studies on cementoblasts, which form cementum are emphasized. It is still unclear which cells cementoblast differentiate from. This study was conducted under the hypothesis that PDL fibroblast can differentiate into either cementoblast or osteoblast depending on the conditions of surrounding tissue. Clinically, with excessive traction force of orthodontic appliances or excessive occlusion hypercementosis is observed, and this has been confirmed histologically. Consequently, activation of cementoblast can be expected in rats when mechanical stimuli are given to PDL fibroblast. Therefore, the purpose of this article is to prove that PDL fibroblast differentiates into cementoblast in rats under mechanical stimuli using histologic and molecular methods. In this study, twenty rats were given hard diet. Ten of them were sacrificed after 1 week, and the others were sacrificed after two weeks. Slides were made from tooth specimen, and they were studied under the microscope. In addition, PDL fibroblast and cementum from the extracted teeth were analyzed with Northern blotting. In histologic examination, as time passed, PDL fibroblast migrated to the dentin side, differentiated into cementoblast, and formed new cementum. In Northern blotting, it was found that mRNA expression of cementoblast-specific proteins such as BSP, OC, OPN, and type I collagen were more prominent in rats sacrificed after 2 weeks of hard-diet than rats sacrificed after 1 week. From these findings we can conclude that PDL fibroblast can differentiate into cementoblast under mechanical stimuli. We think that 'Rat Models' used in this study will be beneficial to future studies regarding cementoblast.

  • PDF

A STUDY ON THE DEGREE OF POLYMERIZATION OF AUTOPOLYMERIZED RESIN FOR REMOVABLE ORTHODONTIC APPLIANCE ACCORDING TO CURING TIME AND CURING METHOD (중합시간과 중합방법에 따른 자가중합형 상교정용 레진의 중합률의 비교에 관한 연구)

  • Yoo, Jong-Wook;Jang, Ki-Taeg;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.296-309
    • /
    • 1999
  • Autopolymerized resin facilitates a more rapid and easier means for the construction of removable orthodontic appliances than heat cured resin. But many reports reveal that more unreacted monomer is found in autopolymerized resin. It is very important to achieve maximum degree of polymerization because if polymerization is inadequate, high level of unreacted monomer has been shown to adversely affect mechanical and physical properties, and also the question of allergy or toxicity to methylmethacrylate must be considered. The purpose of this study was to compare the degree of polymerization according to curing method and curing time. Five groups were desinged ; Group 1 was polymerizied at room temperature($28^{\circ}C$) ; Group 2 in $28^{\circ}C$ water ; Group 3 in $28^{\circ}C$ water under 30psi pressure ; Group 4 in $43^{\circ}C$ water ; Group 5 in $43^{\circ}C$ water under 30psi pressure for 10 minutes, 1 hour 12 hours, 1 day and 3 days. The degree of polymerization was measured by means of Fourier Transform Infrared spectroscopy. The results were as follows: 1. The degree of polymerization increased constantly in accordance with curing time in all groups and after curing for 10 minutes, Group 1 showed significantly higher degree of polymerization after 12 hours and Group 2, Group 3, Group 4, Group 5 after 1 hour(p<0.05). 2. The degree of polymerization decreased in the order of Group 5, Group 4, Group 3, Group 2, Group 1 except when the curing time was 1 hour and 12 hours(p<0.05). 3. The degree of polymerization of Group 4, Group 5 cured at $43^{\circ}C$ showed significantly higher degree of polymerization than Group 2, Group 3 at $28^{\circ}C$ except when the curing time was 1 day(p<0.05). 4. Among Group 2, Group 3 and Group 4, Group 5, the pressure had no effect on polymerization except when the curing time was 12 hours(p<0.05). 5. Between Group 1 and Group 2, the method of storage had no effect on polymerization except when the curing time was 1 hour(p<0.05).

  • PDF

THREE DIMENTIONAL FORCE ANALYSIS OF FORCE SYSTEM IN CONTINUOUS ARCHWIRE BY FINITE ELEMENT METHOD (CONTINUOUS ARCHWIRE의 FORCE SYSTEM에 대한 3차원 유한 요소법적 연구)

  • Row, Joon;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.17-32
    • /
    • 1996
  • It is important to understand the operating mechanism and force system of fixed appliance that most effective for individual tooth movement in various orthodontic appliances. The archwire system of fixed appliance is devided into 3 types, which is continuous arch, segmented arch and sectional arch. The last two types have longer interbracket distance and simple force operating points, so it is easy to control force system by operator. But the continuous arch has shorter interbracket distance and various bracket geometry, so it is hard to control and anaylze the force system. The purpose of this study was three dimentional force and moment analysis of continuous arch system by finite element method, which is similar situation to three dimentional elastic beam in structural engineering. Several sample form of various bracket geometry and artificial lower crowding typodont made by author were constructed, analyzed and compared each other. The results were as follows : 1. The force magnitude is linear proportional to the degree of displacement or tilting of the bracket. 2. The force magnitude is inversely non-linear proportional to the interbracket distance. 3. In three dimensional typodont model, while the force can be compared with that of the sample form in the area where adjacent bracket geometry is simple, the force is much more than the expected value in the area where adjacent bracket geometry is complex.

  • PDF