• Title/Summary/Keyword: Orthodontic Force

Search Result 296, Processing Time 0.025 seconds

A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions (교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구)

  • Lee, Jin-Woo;Cha, Kyung-Suk;Han, Jung-Suk
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.271-281
    • /
    • 2001
  • The Purpose of this study was fourfold - to evaluate the general laws of friction applied to orthodontic conditions, to compare archwire materials under these controlled conditions, to compare ligation method, and to measure the effect of the artificial saliva on friction with these materials Three wire alloys (Cobalt-chromium, Nickel-titanium, Beta-titanium) in two size wires (.016" , .016" ${\times}$.022" ) were examined respect to the bracket (.018" ${\times}$.025" standard), and two ligature material (stainless steel, elastomeric) in dry and wet conditions The results were as follows, 1. The order of frictional force against alloy materials was Co-Cr (lowest), Ni-Ti, and ${\beta}$-Ti(highest) - with the exception of elastomeric ligation under wet conditions. 2. S.S. ligation gave rise to significantly greater friction than elastomeric ligation did. 3. Testing in the presence of saliva, rather than in dry conditions, decreased the frictional force for S.S. ligation with .016" Co-Cr, Ni-Ti, ${\beta}$-Ti. but, increased the frictional force for S.S. ligation with .016" ${\times}$ .022" Co-Cr, Ni-Ti, ${\beta}$-Ti. 4. .016" ${\times}$.022 " wire generated more friction than .016" wire.

  • PDF

Factors affecting force system of orthodontic loop spring (교정용 loop 스프링의 force system에 영향을 주는 요소)

  • Choy, Kwang-Chul;Kim, Kyung-Ho;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.511-519
    • /
    • 1999
  • The shape of orthodontic retraction spring was varied and force system of each case was obtained using numerical analysis and verified with spring tester. The factors for obtaining biomechanically efficient spring under anatomic limitation were suggested as follows. 1. M/F ratio increases and L/D rate decreases as loop height increases. 2. M/F ratio increases and L/D rate decreases as incorporating more wire above minimum bending moment area. 3. M/F ratio decreases and L/D rate decrease as incorporating more wire below minimum bending moment area. 4. M/F ratio can not be greater than spring height no matter how much wire is incorporated at the apex of the loop. 5. Additional moment is necessary to obtain enough M/F ratio for translation under anatomical limitation. 6. Additional moment should be incorporated at every pah of the spring because M/F ratio and L/D rate decreases as horizontal spring length increases. 7. Material, cross section, and shape of the spring influence L/D rate, whereas M/F ratio is influenced by the shape of the spring independent from material and cross section.

  • PDF

3-D FEA on the intrusion of mandibular anterior segment using orthodontic miniscrews (교정용 미니스크류를 이용한 하악 전치 함입 시 변위양상의 3차원 유한요소분석)

  • Park, Hyun-Kyung;Sung, Eui-Hyang;Cho, Young-Soo;Mo, Sung-Seo;Chun, Youn-Sic;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.384-398
    • /
    • 2011
  • Objective: The purpose of this study was to analyze the stress distribution and the displacement pattern of mandibular anterior teeth under various intrusive force vectors according to the position of orthodontic miniscrews and hooks, using three-dimensional finite element analysis. Methods: A three-dimensional finite element model was constructed to simulate mandibular teeth, periodontal ligament, and alveolar bone. The displacement of individual tooth on three-dimensional planes and the von Mises stress distribution were compared when various intrusion force vectors were applied. Results: Intrusive forces applied to 4 mandibular anterior teeth largely resulted in remarkable labial tipping of the segment according to the miniscrew position. All 6 mandibular anterior teeth were labially tipped and the stress concentrated on the labiogingival area by intrusive force from miniscrews placed mesial to the canine. The distointrusive force vector led to pure intrusion and the stress was evenly distributed in the whole periodontal ligament when the hook was placed between the central and lateral incisors and the miniscrew was placed distal to the canine. Conclusions: Within the limits of this study, it can be concluded that predictable pure intrusion of the 6 anterior teeth segment may be accomplished using miniscrews placed distal to the canine and hooks located between the central and lateral incisors.

Autogenous transplantation of tooth with complete root formation (치근단 완성된 치아의 자가이식)

  • Lee, Sul-Hyun;Son, Mee-Kyoung;Park, Ji-Il;Kim, Ok-Su;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.709-716
    • /
    • 2008
  • Purpose: Autogenous transplantation of teeth can be defined as transplantation of teeth from one site to another in the same individual, involving transfer of impacted or erupted teeth into extraction sites or surgically prepared sockets". Successful autogenous transplantation of teeth depends upon a complex variety of factors. Such factors include damage to the periodontal ligament of the donor tooth, residual bone height of the recipient site, extra-oral time of tooth during surgery. Schwartz and Andreasen previously reported that autogenous transplantation of teeth with incomplete root formation demonstrated higher success rate than that of teeth with complete root formation. Gault and Mejare yielded similar rate of successful autogenous transplantation both in teeth with complete root formation and in teeth with incomplete root formation when appropriate cases were selected. This case report was aimed at the clinical and radiographic view in autogenous transplantation of teeth with complete root formation. Materials and Methods: Patients who presented to the department of periodontics, Chonnam National University Hospital underwent autogenous transplantation of teeth. One patient had vertical root fracture in a upper right second molar and upper left third molar was transplanted. And another patient who needed orthodontic treatment had residual root due to caries on upper right first premolar. Upper right premolar was extracted and lower right second premolar was transplanted. Six months later, orthodontic force was applied. Results: 7 months or 11/2 year later, each patient had clinically shallow pocket depth and normal tooth mobility. Root resorption and bone loss were not observed in radiograph and function was maintained successfully. Conclusion: Autogenous transplantation is considered as a predictive procedure when it is performed for the appropriate indication and when maintenance is achieved through regular radiographic taking and follow-up.

AN EXPERIMENTAL STUDY ON THE DYNAMIC 700TH MOVING EFFECTS OF TWO PRECIS10N LINGUAL ARCHS(PLA) FOR CORRECTION OF POSTER10R SCISSOR BITE BY THE CALORIFIC MACHINE (두 종류의 Precision Lingual Arch(PLA)로 구치부 교차교합 치료시 발생할 동적인 치아이동 양상의 차이를 Calorific Machine으로 실험한 연구)

  • Chun, Youn-Sic;Row, Joon;Suh, Moon-Suk;Park, In-Kwon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.29-41
    • /
    • 1998
  • Despite orthodontic treatment(tooth moving) is dynamic act many orthodontists have used mainly static evaluation method for evaluating effectiveness of the orthodontic appliances. They want to find which is better appliance, especially in the treatment results and treatment period when they chose one appliance from sugessted appliances for obtaining same treatment goal. The author and colleagues invented and manufactured new machine for getting information about the relative effectiveness from many suggested orthodontic appliances and we named it Calorific machine. We used this Calorinc machine to find the relative differences about tooth moving mechanism and tooth moving time between the Burstone's PLA(single force mechanism) and Molar-up's PLA(couple mechanism) for correcting the posterior cross bite. We measured the distance of tooth moving on the occlusal X-ray film and recorded the moving time of the anchored(control elctro-thermal tooth) and lingually tipped lower second molars(experimental electro-thermal tooth) and then processed paired t-est by SAS program. The results were as follows. 1. Molar-up's PLA showed more extrusive and horizontal movement than Burstone's PLA at the lingually tipped molar(p=0.0000). 2. There is no finding of tooth movement by Molar-up's PLA at the uprighted molar(p=o.3475) but Burstone's PLA showed a little change(0.2 m) at the same molar(p=0.0001). 3. Burstone's PLA took 17.8 minutes for tooth moving but Molar-up's PLA took only 3.8 minutes(p=0.0001)

  • PDF

A SOFT X-RAY STUDY ON THE BONE REMODELLING IN TOOTH MOVEMENT OF DOG (성견의 실험적 치아이동시 골재형성에 관한 연X선학적 연구)

  • Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.587-592
    • /
    • 1995
  • The purpose of this study was to observe the pattern of bone remodellings in the periodontal ligament of dog, in which experimental tooth movement was performed A control and 5 experimental dogs, one and half year in age, were studied. Light force (50-75g) was applied by placing open-coil spring between left mandibular premolars ; heavy force (250-300g), between right mandibular premolars. Experimental dogs were sacrificed at 12 hours, 1, 3 ,7 and 14 days after force application, respectively. And soft X-ray films were obtained and read on the sectioned periodontal tissue around mandibular premolars. The results were as follows. 1. New bone formation began to be observed in tension side at 7-day and increased at 14-day , No difference was observed between light force group and heavy force group. 2. Bone resorption was observed as a shape of destruction of lamina dura at 3-day and increased gradually at 7-day, 14-day.

  • PDF

A FEM ANALYSIS FOR INITIAL STRESS ON THE UPPER GAMINE BY ORTHODONTIC FORCE OF INTRUSION ARCH WIRE ACTIVATION (Intrusion arch wire activation시 상악 견치에 가해진 초기응력의 유한요소법을 통한 고찰)

  • Kang, Jeong-Weon;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.391-398
    • /
    • 1998
  • The purpose of this study was to find the distribution and measurement of compressive and tensile stress when intrusi- on arch wire is forced engage with upper canine and to analysis stress at each section through FEM. And we compare compressive and tensile ratio at each section. The results were as follows. 1. At FA point and cemento-enamel junction of upper canine, compressive and tensile force ratio is about the same. 2. At apex, compressive force is the four times as tensile force. ; In intrusion, we show root resorption at apex. 3. At Cemento-enamel junction, the compressive and tensile force show the maximun value except FA Point.

  • PDF

Effect of orthodontic force on the amount of tooth movement and root resolution in rat (교정력이 흰쥐의 치아이동량과 치근흡수에 미치는 영향)

  • Kim, Il-Gon;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.551-562
    • /
    • 1999
  • This study was undertaken to investigate the relation between orthodontic force magnitude and the amount of tooth movement. And more light force application for reducing root resorption Twenty-four rats were divided into three experimental groups(A, B, C) based on force magnitude and application method. Springs of 50g force were applied to A group, springs of 100g force were applied to B group and springs of 25g force were applied to C group initially, and after 4 days springs of C group were changed to springs of 50g force. Two kinds of $sentally^{(R)}$(GAC U.S.A.) closed coil spring, 50g and 100g, were used. And we made 25g springs by heat treatment process of 50g springs. Each spring was inserted between the maxillary central incisor and the maxillary left first molar. Amounts of tooth movement were measured everyday by digital caliper($Digimatic^{(R)}$, Mitutoyo, Japan) under inhalation anesthesia for 15 days. After 15 days, all rats were sacrificed and histological samples were obtained with Hematoxyline-Eosin stain and Masson's trichrome stain. Following conclusion were made; 1. Group B showed the mean cumulative tooth movement of $2.19{\pm}0.41mm$ at 15th day, which was greatest among three groups, followed by group C($2.06{\pm}0.10mm$), group A($1.90{\pm}0.49mm$) respectively. however, there was no statistically difference among three groups. 2. All groups showed general tooth movement pattern and A, B, C group finished lag phase at 9th, 8th, 7th day, but there was no statistical significance. 3. Group A,B,C showed root resorption and especially group B showed the most severe root resorption and group C showed milder root resorption than other groups. According to the above results, large initial force with the development of a flirty widespread hyalinized zone may cause severe root resorption, so initial force should be applied lightly to reduce hyalinized area and eventually root resorption and then increased force will induce efficient tooth movement.

  • PDF

STRESS DISTRIBUTION IN ESTHETIC ORTHODONTIC BRACKETS : AN ANALYSIS USING THE FINITE ELEMENT METHOD (유한요소 분석을 통한 심미적 교정 브라켓의 응력 및 구조분석에 관한 연구)

  • Lee, Won-You;An, Ju-Sam;Park, Young-Cheol;Park, Myeong-Kyun;Sohn, Hong-Bum;Jeong, Si-Dong
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.43-49
    • /
    • 1998
  • The aim of this study were to measure and compare the stress level on three type brackets and each other material (stainless steel, ceramic) with tipping and torquing forces by using the finite element analysis and to design biomechanically favorable brackets. For this study, three kinds of brackets were selected(A:Transcend-RMO, B:Signature-Unitek, C:PAW: plain archwire appliance-applied for a patent in Yonsei Udiversity). The slot size of bracket was 0.022inch and the size of archwire was 0.0175x0.025inch and taper shaped archwire was used in PAW. Loading force in tipping was 4.27N and torquing force was 32.858N applied by archwire torsion with 19.7degree and 11.3 degree in C type bracket. The conclusions were that (1) The finite element method proved to be a useful tool in the stress analysis of orthodontic bracket subjected to various forces. (2) With tipping, the stresses were concentrated at the gingival wall of the wire slot where it meets the mesial bracket surface and the incisal wall of the wire slot where it meets the distal bracket surface and with torquing, the stresses were concentrated at the junction of the gingival or incisal wall and base of the slot. (3) The maximum stress value was higher in torquing force than tipping force and therefore it is desirable to design on the basis of torquing force. (4) It was considered that the change in material might be affect on the diminish of stress value in the place of stess concentration. (5) The maximum stress value was highest on PAW bracket when the tipping and torquing force was applied and therefore it would be desirable to use mechanically favorable material on PAW bracket.

  • PDF

EXPERIMENTAL STUDY OF THE VERTICAL LOCATION OF THE CENTERS OF RESISTANCE FOR MAXILLARY ANTERIOR TEETH DURING RETRACTION USING THE LASER REFLECTION TECHNIQUE (Laser 반사측정법을 이용한 상악전치부의 후방견인시 저항중심의 수직적 위치에 관한 실험적 연구)

  • Woo, Jae-Young;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.375-389
    • /
    • 1993
  • The delivery of optimal orthodontic treatment is greatly influenced by a clinician's ability to predict and control tooth movement achieved by applying known force systems to the dentition. It is important to determine the location of the center of resistance of a tooth or group of teeth to better understand the nature of their displacement characteristics under the various force levels. The purpose of this study was to define the location of the centers of resistance of various units of the upper anterior segment for lingually directed 100gm and 200gm force in a dry human skull. The units investigated were composed of four incisors and six anterior teeth. In addition, the effect of change in force magnitude on the location of the center of resistance of these units was investigated. The laser reflection technique was used to measure the initial displacements of the consolidated teeth under loading. The results were as follows: 1. The instantaneous center of resistance for the four anterior teeth was located vertically between level 4 and level 5-that is, at $37.4\%$ apical to the cementoenamel junction level. 2. The instantaneous center of resistance for the six anterior teeth was located vertically just beneath level 5-that is, at $50.3\%$ apical to the cementoenamel junction level. 3. Increasing force levels had little effect on the location of the center of resistance of a given unit. 4. The location of the instantaneous center of resistance shifted apically as the number of dental units consolidated increased.

  • PDF