• Title/Summary/Keyword: Orifice size

Search Result 191, Processing Time 0.025 seconds

An Investigation of the Major Factors Relating to the Flow Fluctuation at a Natural Gas Metering Facility (천연가스 계량설비에서 발생하는 유량 헌팅 현상 원인 분석)

  • An, Seung-Hee;Her, Jae-Young;Jeong, Jong-Tae;Sin, Chang-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.158-165
    • /
    • 2005
  • KOGAS(Korea Gas Corporation) has about a hundred of local stations to supply natural gas to the city gas companies and the power stations. As some severe flow fluctuation phenomena are observed in several governor stations, the investigation about the reasons and factors which are relating to flow fluctuation has been started. Some field surveys hav been carried out and experimental studies have been performed to find the fluctuation mechanism. As a result, it is found that the flow fluctuation is related with the length of straight pipe in front of the meter, the size of the header pipe and the variation of demand at the city gas company and the power station. Furthermore. it is also proved that both the length of the transmitter cable and the status of the coating of signal transmission cable do not affect flow fluctuation, but the measurement range of the differential pressure transmitter influences flow fluctuation. On the other hand, as the averaging the flow fluctuation is converged to less than 0.1 % in almost all of the cases, it is concluded that the quantity of flow fluctuation do not relates to metering accuracy directly.

  • PDF

A Visualization of the Spray from Small Liquid-rocket Engine Injector by Dual-mode Phase Doppler Anemometry (이중모드 위상도플러 속도계측기법에 의한 소형 액체로켓엔진 인젝터 분무의 가시화)

  • Jung, Hun;Kim, Jeong-Soo;Bae, Dae-Seok;Kwon, Oh-Boong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.60-65
    • /
    • 2010
  • A focus is given to the breakup behavior of spray droplets issuing from a nonimpinging-type injector. The analysis has been carried out experimentally by means of the dual-mode phase Doppler anemometry (DPDA). Spray characteristic parameters in terms of axial velocity, mean diameter, velocity fluctuation, and span (width of the size distribution) of droplets are measured down the geometric axis of a nozzle orifice and on the plane normal to the spray stream with the injection pressure variations. As the injection pressure increases, the velocity and its fluctuation become higher, whereas the droplet sizes get smaller. It is also shown that the magnitudes of those parameters are smoothed out by dispersion when the droplets move downstream as well as outwardly. The atomization process is significantly influenced by the injection pressure rather than the traveling distance in the experimental condition presented.

MIXING CONDITIONS WITH SPRAY-JET INTERACTION FOR EFFECTIVE SOOT REDUCTION IN DIESEL COMBUSTION

  • Chikahisa, Takemi;Hishinuma, Yukio;Ushida, Hirohisa
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.17-26
    • /
    • 2002
  • The authors have reported significant reductions in particulate emissions of diesel engines by generating strong turbulence during the combustion process. This study aims to identify optimum conditions of turbulent mixing for effective soot reduction during combustion. The experiments were conducted with a constant volume combustion vessel equipped with abet-generating cell, in which a small amount of fuel is injected during the combustion of the main spray. The jet of burned gas from the cell impinges the main flame, causing changes In the mixing of fuel and air. Observation was made for a variety combinations of distances between spray nozzle and Jet orifice at different directions of impingement. It Is shown that compared with the case without Jet flame soot decreases when the jet impinges. When the jet is very close to the flame, it penetrates the soot cloud and causes little mixing. There were no apparent differences in the combustion duration when the direction of impingement was varied, although the mechanisms of soot reduction seemed different. An analysis of local turbulent flews with PIV (Particle image Velocimetry) showed the relationship between the scale of the turbulence and the size of the soot cloud.

A Study on Combustion Characteristics of Methane Fuel according to Torch Nozzle Diameter in a Constant Volume Combustion Chamber (정적연소기에서 토치의 노즐 직경에 따른 메탄의 연소특성 파악)

  • Lee, Jung-Man;Kwon, Soon-Tae;Park, Chan-Jun;Ohm, In-Young
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Five different size of orifice were applied in a constant volume combustion chamber for evaluating the effects of torch-ignition on combustion. The initial flame development and flame propagation were analyzed by the mass burned fraction and combustion enhancement rate. The combustion pressures were measured to calculate the mass burned fractions and the combustion enhancement rates. In addition, the flame propagations were visualized by the shadowgraph method for the qualitative comparison. The result showed that the combustion pressure and mass burned fraction were increased when using the torch-ignition device. The combustion enhancement rates of torch-ignition cases were improved in comparison with conventional spark ignition. Finally, the visualization results showed that the torch-ignition induced faster burn than conventional spark ignition due to the earlier transition to turbulent flame and larger flame surface, during the initial stage.

A Traction Diverticulum of the Mid-thoracioc Esophagus: A Case Report (식도의 중부계실: 1례 보고)

  • 김규태
    • Journal of Chest Surgery
    • /
    • v.8 no.1
    • /
    • pp.51-56
    • /
    • 1975
  • The typical traction diverticulum of the mid-thoracic esophagus is conical or funnel shaped with a wide orifice, is small (rarely exceeding 2cm in length), and is situated horizontally or extends superiorly. It is a true diverticulum, having a complete investment by the esophageal muscle coats. Each of these characteristics promotes easy emptying of the diverticulum. Since food accumulation is presented, there is no tendency to progressive enlargement of the sac, and no associated dysphagia. The diverticula of mid-esophagus rarely develop and rarely produce symptoms. When symptoms develop, they are usually caused by granulomatous infections of the mediastinal lymph nodes. And also such diverticula only rarely give rise to significant complications, the most serious of which is a tracheobronchial fistula. Generally when such complications develop or a diverticulum itself produces symptoms, moderate or severe, surgery intervenes. A case of mid-esophageal diverticulum, traction type, which surgically treated with good results, was experienced at the Department of Thoracic Surgery of Kyung-Pook University. School of Medicine. In this case, there were substernal discomfort, acid regurgitation, and back pain for about 6 months. On the operative findings, it was noticed that the diverticulum was developed by traction and adhesion of perihilar nodes to the esophageal wall. The diverticulum was a small finger tip size and the neck of it was obscure. The surrounding inflammatory change was minimal.

  • PDF

PRESSURE MODULAION ON MICRO-MACHINED PORT FUEL INJECTOR PERFORMANCE

  • Kim, H.;Im, K.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2004
  • An experimental study was carried out to characterize the spray atomization process of micro-machined port fuel injectors with a piezoelectric atomization device, which can generate pressure pulsations through vibration of a piezoelectric transducer. In this study, several types of micro-machined arrays such as 30∼200-microns of hole arrays were tested. Both a dual-stream and a central-port injectors with micro-machined arrays were tested and compared with normal port fuel injectors. The spray visualization was conducted to characterize overall spray structure and phase Doppler particle analyzer (PDPA) system was used to quantify the droplet size and velocity. In addition, the pressure history was recorded by using digitized signal from pressure transducer. The results showed that modulation is effective to the spray atomization for tested injectors and atomization performance depends on injector design factors, orifice sizes, and frequency and power of the modulator. A number of resonance frequencies of the modulator was modified by injector parameters and temperature. In addition, our results suggested that design of sufficient space among holes is critical to avoid droplet coalescence in the multi-hole micro-machined injectors.

A Fabrication of the Micro Valve with Free Floating Structure (Free Floating 구조를 갖는 마이크로 밸브의 제작)

  • Son, Mi-Young;Mun, Byung-Phil;Jeon, Ho-Seung;Han, Jin-Woo;Kim, Chul-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.136-139
    • /
    • 2002
  • Previous valves have initial gap problem, high voltage or high pressure problem. In this paper, various micro valves with free floating structure have been fabricated and tested to solve the initial gap and high pressure problems. The paper presents how to etch Parylene-C which is a valve cap material without A1 mask layer. The maximum flow-rate of fabricated micro valve is$118{\mu\ell}$/min with $370{\mu}m$ orifice size and the leakage at the initial and reverse pressure is not observed.

  • PDF

Thermal Characteristics of Foams and Discharge of Fire-Protection Foam Spray Nozzle (폼 분무 노즐 방사 분포 및 폼의 열적 특성 연구)

  • Kim, Hong-Sik;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.151-158
    • /
    • 2005
  • A characteristic of discharge for a foam spray nozzle with various parameters was investigated. The discharge patterns from a fire foam spray nozzle are important to evenly spray over a maximum possible floor area. Two parameters of a foam spray nozzle were chosen, and compared with those from the standard one. Also, in order to evaluate the performance of discharged foam agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams were experimentally investigated. A simple repeatable test for fire-protection foams subjected to fire radiation was developed. This test involves foam generation equipment, a fire source for heat generation, and data acquisition techniques. Results show that the bubble size of foam is increased by large inside diameter of orifice or closed air hole, but phenomenon of discharge angle and expansion ratio is opposite. For the case of the open air hole, liquid film of a circular cone discharges with formation, growth, split and fine grain. In case of the closed air hole, a pillar of foam solution discharges with that. Though the temperature gradient in the foam increases with increased foam expansion ratio. it is not change with increased intensity of heat flux.

Removal of submandibular calculi by surgical method and hydraulic power with curved needle: a case report

  • Cho, Seong-Ho;Han, Ji-Deuk;Kim, Jung-Han;Lee, Shi-Hyun;Jo, Ji-Bong;Kim, Chul-Hoon;Kim, Bok-Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.3
    • /
    • pp.182-185
    • /
    • 2017
  • Sialolithiasis, the most common salivary gland pathology, is caused by calculi in the gland itself and its duct. While patients with small sialoliths can undergo conservative treatment, those with standard-size or larger sialoliths require sialolithotomy. In the present case study, we removed two sialoliths located beneath the mucosa in the posterior and anterior regions of Wharton's duct, respectively. For the posterior calculus, we performed sialolithotomy via an intra-oral approach; thereafter, the small anterior calculus near the duct orifice was removed by hydraulic power. This method has not previously been reported. There were no complications either during the operation or postoperatively, and the salivary function of the gland remained normal.

Analysis of High Volume Slit Type Two-Stage Virtual Impactor for Particle Size Classification (특정크기 입자농축을 위한 대유량 슬릿형 2단 가상충돌기의 성능분석)

  • 박성호;김상수;오명도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.285-291
    • /
    • 1991
  • A two-stage slit type virtual impactor based on the concept of the single stage virtual impactor has been designed, fabricated, and evaluated for the purpose of concentrating the suspended particles in the air with the size range of 1.8-4.5 .mu.m and handling large flow volume. Monodisperse methylene blue particles have been generated with vibrating orifice aerosol generator (VOAG). The separation efficiency and concentration efficiency have been measured by the UV-visible absorption spectrometry. Previous study for a single stage virtual impactor were used to determine the design parameters such as 50% cut-off sizes and dimensions of the two stage virtual impactor. The separation efficiency curve and 50% cut-off Stokes number(cut-off sizes) are not sensitive to the nozzle Reynolds number, but sensitive to the ratio between the minor flow rate and the total flow rate, The measured concentration efficiency was compared with the maximum concentration efficiency determined by the separation efficiencies of the first and the second stages. The differences between the measured and the maximum concentration efficiencies result from the wall loss due to the deposited particles on the internal walls inside the impactor.