• Title/Summary/Keyword: Orifice size

Search Result 191, Processing Time 0.022 seconds

Combustion Characteristics of Volume Variation of Torch in a CVCC (토치 점화 장치의 체적에 따른 연소특성 파악)

  • Kwon, Soon-Tae;Kim, Hyeong-Sig;Choi, Chang-Hyeon;Park, Chan-Jun;Ohm, In-Young
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2010.04a
    • /
    • pp.166-170
    • /
    • 2010
  • Six different size of torch-ignition device were applied in a constant volume combustion chamber for evaluating the effects of torch-ignition on combustion. The torch-ignition device was designed six different volumes and same orifice size. The combustion pressures were measured to calculate the mass burn fraction and combustion enhancement rate. In addition, the flame propagations were visualized by shadowgraph method for the qualitative comparison. The result showed that the combustion pressure and mass burn fraction were increased when using the torch ignition device. And the combustion duration were decreased. The combustion enhancement rates of torch-ignition cases were improved in comparison with conventional spark ignition. Finally, the visualization results showed that the torch-ignition device the torch-ignition induced faster burn than conventional spark ignition due to the earlier transition to turbulent flame and larger flame surface, during the initial stage. And the initial flame propagation was effected torch-ignition volume.

  • PDF

Performance of Mini-Sprinkler - (2) Size of Droplets (미니 스프링클러의 살수 기능 - (2) 살수 입자의 크기)

  • 서상룡;성제훈
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.183-189
    • /
    • 1997
  • This study was performed to Investigate size of droplet sprinkled from mini-sprinkler. Twelve different kinds of the sprinkler having various structures and sizes of nozzle orifices were selected and tested. Diameters of the droplet reached at several distances from a sprinkler were measured by a machine vision system and the volume median diameters (VMM) were determined statistically. The size of droplet was not affected much by the size of nozzle orifice of a sprinkler but was rather more affected by structure of the sprinkler, especially by the shape of spreader of the sprinkler. Experiment of varying pressure of sprinkling water validated that the size of droplet was inversely proportional to water pressure powered by 1/3. Hence the size of droplet at any water pressure could be easily estimated from experimental data. The size of droplet increased as travel distance of the droplet increases in a relationship of and order function. The size of droplet of the tested sprinkler were in the ranges of 100-300fm within 1m of droplet travel distance, 230~470${\mu}{\textrm}{m}$ within 1~2m of droplet travel distance and 300~770${\mu}{\textrm}{m}$ within 2~3m of droplet travel distance.

  • PDF

Performance of Absorption Diffuser Silencers (흡음형 디퓨저 소음기의 성능)

  • 정갑철;현승일;이종우;권영필
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.377-384
    • /
    • 1994
  • This paper is an investigation of the performance of absorption diffusers to suppress the vent noise emitted when high pressure gas is throttled. First, experiment for the static performance is carried out. When there is no through-flow, the insertion loss has been obtained in terms of 1/3 octave band spectrum and the effect of the number of diffusers and the thickness of the absorption material on the static performance has been obtained. And the similarity in the spectrum of the static insertion loss is confirmed by comparing two similar models with different size. Second, the dynamic performance has been obtained by experiment using blow-down of compressed air from a storage tank through an orifice of diameter 10 mm. The back pressure by the diffuser is measured and compared with that of a single diffuser. It is found that the insertion loss of asingle diffuser is very low around 3 dB at high frequencies with negative value at low frequencies. By absorption material between the diffuser tubes, however, the performance is increased considerably. Without flow the static insertion loss increases by 3 - 4 dB by doubling the thickness or the density of the absorptionmaterial. With flow, however, the dynamic insertion loss increases. While, the back pressure by the diffuser is small enough to be neglected.

  • PDF

Discharge and Fire Extinguishing Test of Inert Gas Clean Agent (불활성 가스계 청정 소화약제의 방출 및 소화)

  • Song Eun-Seok;Kim Jae-Duck;Park Yang-Won
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.29-36
    • /
    • 2005
  • We carried out discharge and fire extinguishing tests of new inert gas clean agent, which consists of $92\%$ nitrogen and $8\%$ carbon dioxide, as an alternative of Halon that is banned by Montreal Protocol to protect the ozone layer of the earth. Discharge and fire extinguishing tests were performed in $27m^3$ and $190m^3$ rooms with piping which allows gaseous agent to transport from storage to test rooms. We confirmed that it took less than regulation time, 60 seconds for the discharge of over $95\%$ initial charged amounts. Discharge test variables were piping length and orifice size. Fire extinguishing tests verified that this new inert gas clean agent is suitable for both n-Heptane fire and deep seated fire of wood crib.

A Study on the Distribution of Cylindrical Disk Spray by a Impinging Disk (충돌판에 의한 원판형 분무의 공간분포에 관한 실험적 연구)

  • 차건종;김덕줄
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.251-262
    • /
    • 1995
  • The goal of this study is to provide fundamental information on the design of a new diesel injector system. The cylindrical disk spray was made by an impinging disk insited below the exit of air-assist atomizor. The disintegration processes on a twin-fluid atomization by air-assist atomizor were investigated. Liquid jet was disintegrated at the condition that wavelength was equal and longer than the circumference of the liquid jet, .lambda. .geq. .pi.do. However, the wavelength and the diameter of the liquid jet were decreased according to the increasing of air velocity. The relative density distribution of droplets and pattern of spray by impinging disk were investigated with a C-CCD. Optimum design conditions for cylindrical disk spray were also achieved. The pattern of cylindrical spray can classified according to the size of the disk and the distance from the nozzle tip to the disk. When the space of the disk and the nozzle tip was narrow and the diameter of the disk was larger than that of the air orifice of the nozzle exit, the good distribution of spray could be achieved. When the air flowrate was constant, the spray width was decreased according to the increasing of the liquid flowrate. When the liquid flowrate was constant, the spray width was decreased according to the increasing of the air flowrate.

Investigation of Pintle Shape Effect on the Nozzle Performance (핀틀 형상이 노즐 성능에 미치는 영향에 관한 연구)

  • Kim, Joung-Keun;Park, Jong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.8
    • /
    • pp.790-796
    • /
    • 2008
  • Typical solid rocket motors have a fixed propellant grain shape and nozzle throat size resulting in a fixed motor thrust. Pintle nozzle has been suggested as a means of providing variable thrust while maintaining the inherent advantage of solid rocket motors. In this study, the pintle shape effect on nozzle performance is investigated using experimental-aided Computational Fluid Dynamics(CFD). The pintle shape is modified by a principle of monotony. CFD analysis is performed using Fluent by applying the turbulent model. This analysis indicates that nozzle thrust and pintle load are influenced by change of nozzle shock pattern and flow separation due to pintle shape and there exists a high-performing pintle shape.

Basic Design of High Pressure LOx Lines for a Liquid Rocket Engine (액체로켓엔진 액체산소 고압 배관부 기본설계)

  • Moon, Il-Yoon;Yoo, Jae-Han;Moon, In-Sang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.107-110
    • /
    • 2009
  • A basic design for a Technical Development Model (TDM) of liquid oxygen lines from the turbopump exit to the oxidizer valves of the combustion chamber and the gas generator was conducted to develop a turbopump-fed liquid rocket engine. The TDM is composed of straight lines, elbows, bellows, a branch, an orifice, flanges and a heat insulator. Materials were determined by consideration of operation conditions, weight constraint and manufacturing procedures. The size and the location of each component were determined by flow analysis of the required flowrate and the pressure loss. Basic designs of the components were conducted by consideration of the operating temperature and the maximum expectation operating pressure. The safety factors were evaluated by structural analysis of design of each component.

  • PDF

A Study on the Reaction Force Characteristics of the Gas Spring for the Automotive (자동차용 가스 스프링의 반력 특성에 관한 연구)

  • Lee, Choon Tae
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.35-40
    • /
    • 2015
  • A gas spring provides support force for lifting, positioning, lowering, and counterbalancing weights. It offers a wide range of reaction force with a flat force characteristic, simple mounting, compact size, speed controlled damping, and cushioned end motion. The most common usage is as a support on a horizontally hinged automotive tail gate. However, its versatility and ease of use has been applied in many other industrial applications ranging from office equipment to off-road vehicles. The cylinder of a gas spring is filled with compressed nitrogen gas, which is applied with equal pressure on both sides of the piston. The surface area of the rod side of the piston is smaller than the opposite side, producing a pushing force. The magnitude of the reaction force is determined by the cross-sectional area of the piston rod and the internal pressure inside the cylinder. The reaction force is influenced by many design parameters such as initial chamber volume, diameter ratio, etc. In this paper, we investigated the reaction force characteristics and carried out parameter sensitivity analysis for the design parameters of a gas spring.

A Study on Flow Rate Characteristic and Dynamic Performance on Diaphragm Solenoid Valve (다이어프램형 밸브의 유량특성과 동적성능에 관한 연구)

  • Jeong, C.S.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.3
    • /
    • pp.27-33
    • /
    • 2013
  • Solenoid valve has used in various industrial field extensively. A solenoid valve has different size, shape and method of operation accordantly to industrial field. Many researchers study on kinds of solenoid valve such as flow rate, dynamic, magnetic field, valve shape and operating method. But the flow rate characteristic and dynamic response time performance on the diaphragm valve are not studied. This paper describes the flow rate characteristic and dynamic response time performance on the diaphragm valve. At first, the diaphragm valve is simulated in AMESim simulation tool. AMESim model found that an effect of valve performance depends on parameter. The parameter is the diaphragm orifice area. And the performance test bench confirms the effect in this parameter. Finally, it finds out the flow rate characteristic and dynamic response time performance on the diaphragm valve.

Energy Separation Characteristics of Single Hole Vortex Generator (단일 유로를 갖는 와류발생기의 에너지분리 특성)

  • Yu, Gap-Jong;Jang, Jun-Yeong;Choe, In-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1005-1012
    • /
    • 2001
  • When vortex tubes are applied to enhance the coefficient of performance of refrigeration system, the smaller one is preferable. However, the existing vortex generator with a nozzle hole diameter of 0.5mm was not suitable due to chocking of the nozzle hole. Therefore, experimental investigation was made to find an appropriate geometry of vortex generator, which could give a comparable effect of energy separation to commercial ones without chocking problem. The tested vortex generators were tangential and spiral types, which had single inducing channel with larger cross-sectional area than that of conventional multi-hole ones. The experimental result showed that the performance of the spiral type was better than that of the tangential one. As a small size of spiral one, the diameter of cold-end orifice is proposed to an half of tube diameter for the application to refrigeration system, while cold mass fraction ratio is 0.5∼0.6 for a desirable operation.