• Title/Summary/Keyword: Orifice

Search Result 1,059, Processing Time 0.026 seconds

Numerical Study on the Effects of Velocity Profile Distortion and Swirl on Pressure Difference of Orifice Flowmeter Due to Pipe structure (배관구조에 따른 속도분포 변형과 선회가 오리피스 유량계의 압력차에 미치는 영향에 대한 수치적 연구)

  • Kim, Hong-Min;Kim, Kwang-Yong;Her, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1450-1456
    • /
    • 2003
  • Three-dimensional pipe flows with elbows, tees and headers in three different pipe systems are calculated to estimate the effect of asymmetry of axial velocity profile and swirl on measuring accuracy of an orifice flowmeter. It is evaluated how the pressure difference across the orifice is dependent on the upstream straight pipe length and how swirl intensity, swirl angle, and axial velocity distribution affect the measuring error of the orifice flowmeter. From the results, it is found that variation of the pressure difference across the orifice is negligible in case that maximum swirl angle is less than 2$^{\circ}$, and also that the pressure difference across the orifice is more sensitive to the asymmetry of axial velocity profile rather than the swirl intensity.

Numerical Study on Improvement of Mixing Equipment' Plan in a Water Treatment Plant (수리해석을 이용한 정수장내 혼화장치 설계 개선에 관한 연구)

  • Oh, S.Y.;Hyun, D.S.;Oh, J.J.;Lee, S.H.;Lee, N.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.777-782
    • /
    • 2001
  • In this study, we used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Numerical study was performed using FLUENT, a commercial code, to standard design and production of effective In-line orifice mixer. As variable for exactly standardizing, a proper ratio between an outer diameter of cone and a diameter of pipe, a distance between cone and orifice, a determination of orifice diameter for an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice - (공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향-)

  • 이병화;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

Experimental Study on Characteristics of Two-Phase Flow through a Bypass Orifice Expansion Device

  • Choi, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2001
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which was a short tube haying a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them. and it would enhance the seasonal energy efficiency ratio of an inverter heat pump system, Based on experimental data, a semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model`s prediction was within $\pm$5%.

  • PDF

Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator (스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device (바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구)

  • Choi, J.M.;Kim, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF

Detention Orifice Design for Non-point Source Management Using SWMM (SWMM을 이용한 비점오염원 관리 저류지의 오리피스 설계기법 연구)

  • Cho, SeonJu;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.686-692
    • /
    • 2012
  • This study illustrates how to design and evaluate a non-point sources management detention pond using SWMM. In particular, special attention is given to the orifice design. In SWMM, orifice properties that need to be defined include its height above the bottom of the storage unit, its type, its geometry and its hydraulic properties. Among the various characteristics of orifice, the orifice hole size which is closely related to hydraulic retention time is focused in this study. Sensitivity analysis of orifice size in annual non-point sources reduction efficiency is carried out. In addition, a methodology which can be used to design a virtual junction in SWMM has been proposed to quantify water quality improvement triggered by the detention pond installation. As a result, it is recommended that a detention outlet should be designed to be about 2 to 3 days of hydraulic retention time.

Research on fast cool-down of orifice pulse tube refrigerator by controlling orifice valve opening

  • Kim, Hyo-Bong;Park, Jong-Ho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.36-40
    • /
    • 2010
  • In this paper, a noble method for rapid cooldown of pulse tube refrigerator (PTR) was proposed and experimentally investigated. An orifice pulse tube refrigerator generates refrigeration effect by expansion PV work at the cold-end, and its amount is affected by the orifice valve opening. There exists the optimum valve opening for maximum cooling capacity and it varies as cold-end temperature. It is verified from simulation results using isothermal model that the optimum valve opening increases as the cold-end temperature increases. In the experiments, a single stage orifice pulse tube refrigerator is fabricated and tested. The fabricated PTR shows 97.5 K of no-load temperature and 10 W at 110 K of cooling capacity with the fixed orifice valve opening. From experiments, the initial cooldown curve with four cases of valve opening control scenario are obtained. And it is experimentally verified that the initial cooldown time can be reduced through the control of orifice valve opening.

Numerically Analytical Design of An Orifice Fluid Damper (오리피스 유체댐퍼의 수치해석적 설계)

  • 이재천;김성훈;문석준
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.105-112
    • /
    • 2003
  • This paper presents the numerical design technology of a passive orifice fluid damper system especially for the characteristics between the damper piston velocity and the damping force. Numerical analysis with the visual interfacial modeling technique was applied into the analysis of the damper system's dynamics. A prototype orifice fluid damper was manufactured and experimentally tested to validate the numerical simulation results. The performances of various damper system schemes were investigated based on the verified numerical simulation model of orifice fluid damper.

The Dynamic Characteristics of Pump-fed Hydraulics due to Different Diameter Ratios of the Plate Orifice (펌프 가압식 추진제 공급유로에서의 오리피스 개도에 따른 동적 수력특성 변화)

  • Kim, Hyung-Min;Ko, Tae-Ho;Kim, Sang-Min;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.313-317
    • /
    • 2009
  • The orifice in the propellent feeding pipe line of a Liquid Rocket Engine(LRE) is used to balance the pressure of the pipe line. When a LRE starts up, pressure at the upstream of the orifice rapidly increases. In this case, pressure waves occuring by resistance of the orifice may induce low frequency instability in the pipe line. For this reason the study of dynamic characteristics of orifices is needed to prevent the instability. A pump is used to build up the pressure, and the pressure is measured upstream and downstream of the orifice when the orifice diameter is changed. With the increase of orifice diameter, water hammer decreases, but the effect of resistance downstream is increases.

  • PDF