• 제목/요약/키워드: Orientation of occlusal plane

검색결과 6건 처리시간 0.024초

한국 성인 유치악자의 상악전치 및 교합평면에 관한 연구 (A Study on the Position of the Maxillary Anterior Teeth and Orientation of Occlusal Plane in Dentulous Korean Adults)

  • 이준석
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.197-203
    • /
    • 2007
  • Statement of problem: It is very important to establish the suitable position for artificial maxillary anterior teeth and the orientation of occlusal plane in fabrication of the complete dentures. Incisive papilla has been considered the most useful anatomic landmark in the arranging of a maxillary anterior artificial teeth. Purpose: To determine correct position of upper anterior artificial teeth in complete denture patients, relationship of incisive papilla, intercanine line, occlusal plane were evaluated in Korean adults. Materials and Method: Maxillary casts were made in 60 Korean dentate subjects. Each cast was mounted in Hanau modular articulator using Hanau spring bow. Then, anatomic landmarks were determined in each cast. Distance from central incisor to incisive papilla, distance from incisive papilla to intercanine line and discrepancies between frankfurt plane and occlusal plane were measured and analysed. Results: 1. The mean distance between the posterior point of incisive papilla and the incisal edge of central incisor was 11.20 mm (in male 11.77 mm, in female 10.55 mm) and there was no significant difference in measured values between male and female 2. The mean distance between the posterior point of incisive papilla and intercanine line was 2.52 mm (Male 2.57 mm, Female 2.35 mm) and there were no significant differencies in measured values between male and female 3. The mean discripancy between the Frankfurt plane and the occlusal plane were 9. 75 degree (Male 9.81 degree, Female 9.55 degree), and there was no significant difference in measured values between left and right sides.

한국 성인 유치악자의 교합평면 및 수직고경에 관한 연구 (A STUDY ON THE OCCLUSAL PLANE AND THE VERTICAL DIMENSION IN KOREAN ADULTS WITH NATURAL DENTITION)

  • 박정형;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.41-51
    • /
    • 2005
  • Statement of problem. Anatomic landmarks have been used in the orientation of occlusal plane and the determination of vertical dimension for edentulous patients. Such as labial vestibules of anterior region and hamular notches, retromolar pads of posterior region are very useful anatomic landmarks for fabrication of occlusion rim because they are to be identified on master casts. Therefore, if average distances between landmarks of maxillae and mandible in dentate subjects are measured and applied, not only occlusal plane but also vertical dimension can be established initially. Purpose. The purpose of this study is to measure vertical distances between anatomic landmarks and to present a guide to the orientation of occlusal plane and the determination of vertical dimension of edentulous patients. Material and method. Upper and lower border-molded casts were made in 93 Korean dentulous subjects, mean age 25 years. Incisal edges of central incisors, bottoms of labial vestibules, hamular notches and the half level of retromolar pads were marked on casts. Measurements of vertical distances from incisal edge of central incisor to the bottom of labial vestibule, between upper and lower bottoms of labial vestibules, from hamular notch to retromolar pad and from hamular notch to the occlusal plane established by the incisal edge of maxillary central incisor and mesiopalatal cusps of both maxillary first molars were made on each cast. Results and conclusion. 1. The mean distance from the incisal edge of central incisor to the bottom of labial vestibule was 20.8mm(SD 1.7) on upper casts and 17.3mm(SD 1.4) on lower casts. 2. The mean distance between both bottoms of labial vestibules of upper and lower casts was 35.0mm(SD 2.7). 3 The mean distance from hamular notch to the half level of retromolar pad was 5.0mm(SD 1.3). 4. The mean distance from hamular notch to occlusal plane was 7.9mm(SD 1.5). 5. Distances from incisal edge of central incisor to labial vestibule on lower casts(P<0.01) and from hamular notch to retromolar pad(P<0.0001) were greater in male than in female.

A determination of occlusal plane comparing different levels of the tragus to form ala-tragal line or Camper's line: A photographic study

  • Kumar, Sandeep;Garg, Sandeep;Gupta, Seema
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.9-15
    • /
    • 2013
  • PURPOSE. The purpose of this study was to determine accurately the part of the tragus to be used to form the Ala-Tragal line or Camper's line in orthognathic profile patients. MATERIALS AND METHODS. 150 dentate subjects with age of 18-40 years with orthognathic profile were sampled. Life-size lateral digital photographs of the face with fox plane were taken in natural head position. Different angles between Eye-Ear plane and occlusal plane ($OT_1$-OP), Eye-Ear plane and ala-superior border of tragus ($OT_1-AT_1$), Eye-Ear plane and ala-middle border of tragus ($OT_1-AT_2$) and Eye-Ear plane and ala-inferior border of tragus ($OT_1-AT_3$) were calculated using computer software package, AutoCAD 2004. From the three angles formed by the Eye-ear plane ($OT_1$ or FH plane) and the ala-tragal lines, the one closest to the angle formed between Eye-Ear plane ($OT_1$) and occlusal plane (OP) was used to determine the occlusal plane of orientation. The obtained results were subjected to ANOVA F test, Tukey's Honestly significant difference test, followed by Karl Pearson coefficient of correlation test. P values of less than 0.05 were taken as statistically significant. RESULTS. The mean of base line angle i.e. $OT_1$-OP angle ($11.96{\pm}4.36$) was found to be close to $OT_1-AT_2$ angle ($13.67{\pm}1.93$) and $OT_1-AT_3$ angle ($10.31{\pm}2.03$), but $OT_1$-OP angle was found to be more closer to $OT_1-AT_3$ angle. Comparison of mean angles showed that $OT_1$-OP angle in both males (11.68) and females (12.51) is close to $OT_1-AT_3$ angle (males- 11.01, females- 11.95). CONCLUSION. The line joining from ala to the lower border of the tragus was parallel to the occlusal plane in 53.3% of the subjects. There was no influence of the sex on the level of occlusal plane.

정상교합자의 치축경사도에 관한 $45^{\circ}$ 측모두부방사선 계측학적 연구 ([ $45^{\circ}$ ] OBLIQUE CEPHALOMETRIC ANALYSIS OF MESIODISTAL AXIAL INCLINATION IN NORMAL OCCLUSION)

  • 김경호;박영철
    • 대한치과교정학회지
    • /
    • 제18권1호
    • /
    • pp.65-78
    • /
    • 1988
  • The development of good arch form, the orientation of the dentition with relation to the craniofacial skeleton and the establishment of correct relationship of axial inclination of upper and lower teeth are required in normal occlusion, but different teeth present different degrees of axial inclination. The purpose of this study was to investigate the axial inclination of upper and lower teeth by analyzing $45^{\circ}$ oblique and $90^{\circ}$ cephalometric roentgenograms of 35 Korean males and 34 females with normal occlusion. The obtained results were as follows: 1. Mean and standard deviation of mesiodistal axial inclination of upper and lower teeth related to palatal plane and occlusal plane were obtained. 2. Mesiodistal axial inclination of upper first premolar was nearly perpendicular to palatal plane, and the axis of lower first premolar was nearly perpendicular to occlusal plane. 3. There was no difference in the mesiodistal axial inclination of anteriorly positioned teeth between the three groups: third molar eruption into good alignment (Group 1), third molar impaction or partial eruption (Group 2), third molar agenesis (Group 3). 4. There were low correlationships only between the axial inclination of central incisor and the mesiodistal axial inclination of canine and first premolar, but no correlationships between central incisor and posterior teeth behind first premolar.

  • PDF

교모 환자에서 안면 스캔을 활용하여 교합 평면을 재설정한 전악 보철 수복 증례 (Full mouth rehabilitation with reorientation of occlusal plane using facial scan: a case report)

  • 김은경;오세은;김지환
    • 대한치과보철학회지
    • /
    • 제62권1호
    • /
    • pp.64-71
    • /
    • 2024
  • 전악 보철 치료에서 가장 중요한 것은 환자의 수직 교합 고경이 적절한지 평가하는 것이며, 필요시 교합 고경 거상을 통해 회복해 주어야 한다. 수직 교합 고경이 낮으면 저작력이 감소되며 심미적인 문제 뿐만 아니라 저작근의 과수축이나 과두의 후방 변위가 일어난다. 본 증례는 수차례에 걸쳐 전악에 이르는 보철 수복 치료를 받은 후 부적절한 수직 교합 고경으로 인해 발음 및 심미에 불만족스러워 하는 환자에게 수직 교합 고경 거상을 동반해 전악 보철 수복 치료를 했다. 디지털 진단 장비를 활용해 환자의 수직 교합 고경, 교합 평면, 보철물 상태 등을 종합적으로 평가하고 치료계획을 수립했다. 3D 안면 스캔으로 얼굴의 해부학적 구조를 파악하고 교합 평면을 설정한 다음 이에 맞추어 디지털로 진단 왁스업 했다. 전치부 기준 약 5 mm의 수직 교합 고경 거상을 결정하였으며 기존 식립된 양측 상하악 구치부의 임플란트의 상부 보철과 상악 4전치를 제외한 모든 잔존 치아를 수복하였다. 치료 순서는 양측 구치부의 임플란트 보철물을 먼저 제작하여 안정적인 교합 접촉을 형성한 뒤 자연치의 보철물을 제작하는 방식으로 진행했으며, 적응된 임시 수복물을 반영하여 동일한 순서로 최종 보철물을 제작하였다. 이와 같이 전악 보철 치료에서 안면 스캔을 이용해 환자의 facial landmark와 조화를 이루는 교합 평면을 설정하고 디지털 진단 왁스업 과정을 통해 적절한 치료계획을 수립하였고, 거상된 교합 고경을 유지하기 위해 구치부 임플란트를 이용한 결과 복잡한 기공 과정을 줄이고, 치료 시간을 단축할 수 있었다.

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.