• Title/Summary/Keyword: Oriental medical device

Search Result 116, Processing Time 0.071 seconds

Pulse Wave Velocity Measured by Radial Artery Clip-type Pulsimeter Equipped with a Hall Device and Electrocardiogram (홀소자가 구비된 요골동맥 집게형맥진기와 심전도로 측정된 맥파전달속도)

  • Lee, Kyu-Hwan;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.130-134
    • /
    • 2013
  • The clip-type pulsimeter equipped with a magnetic sensing Hall device and the most popular body sign of the electrocardiogram (ECG) were investigated in order to analyze the pulse wave velocity (PWV). The PWV simultaneously calculated by means of time difference between the maximum peak of ECG pulse wave and the starting point of radial artery pulse wave, and distance difference between the heart position and the radial wrist position. The PWV analyzed from the clinical data was a wider scope of 5~7 m/s with an average value of 6 m/s. By the prediction of blood vessel's elasticity from the analysis of PWV, it may be useful for developing an oriental-western diagnostic medical signal device for a U-health-care system in the future.

A Review on Clinical Studies on Gynecological Disease by Using a Pulse Diagnosis Device (맥진기를 활용한 부인과 질환 대상 임상연구 고찰)

  • Kim, Ji-Hye;Kim, Jong-Yeol
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.3
    • /
    • pp.23-34
    • /
    • 2016
  • Objectives: The purpose of this study was to survey the status of clinical use of a pulse tonometric device (PTD).Methods: We searched domestic and international articles using the PTD from online medical databases including OASIS, RISS, DBpia and PubMed. We selected articles on clinical application of PTD but excluded articles on mechanical design or software programming for developing a new PTD. Finally we found 13 articles and classified the articles according to the disease of clinical study.Results: Out of the 13 articles, 5 were focused on the dysmenorrhea. Three articles were focused on the infertility, two article were focused on the post mastectomy. According to the results, the pulse energy has been widely used in research as the primary outcome.Conclusions: We found out that until now the researches on clinical application of PTD mainly had been performed for producing a variety of PTDs. This results of this study will be used as a useful information during perform a clinical study and clinics. We suggest that the standard operating procedure for PTD will be developed, and researches for development and its application of various new contents will be performed.

Case Study Of Hair Growth Effect of The Hair Scalpdetox Five Step Program (두피해독 5단계 프로그램의 발모효과 사례 연구)

  • Jeong, Keum-Yong;Tak, Sang-Sook;Kim, Ju-Hee;Park, Jeong-Yong;Hong, Kweon-Eui;Ju, Mi-Sook
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.3
    • /
    • pp.259-273
    • /
    • 2016
  • Objectives: Objectives of this research is to test hair growth effect of the hair scalpdetox five step program.Methods : Data for this research is gathered from participants who are suffering from hair loss and have completed scalpdetox five step program at a esthetic by receiving treatments twenty times constantly with once or twice a week during three months from March 2015 to April 2016. The hair scalpdetox program consists of five steps : the first step is shampooing, the second is scalp massage with aroma oils, the third is vertical meridian scrapping massage, the fourth is applying scalp and hair pack made with natural herbs, and the last is scalp massage with an indirect high frequency massaging device.Results: Subjective evaluations from the participants show that overall hair scalp conditions are meaningfully improved. Participants evaluated that tested approach helps hair growth by increasing the number of hair (p<.01) and helps to make their hair thicker (p<.01). Visual observations with magnification by 60 times and 200 times show improvement in hair scalp condition and clean opening of pores. Photographs of hair loss parts of each participant also show improvement in hair growth.Conclusions: From the evaluation of the participants for the test program and from visual observations, we conclude that suggested hair scalpdetox five step program has effect on improving scalp, hair condition, and hair growth.

The Technological Concept of Fibroscan and its Clinical Usefulness in the Traditional Korean Medical Field (비침습적 간섬유화 측정기(Fibroscan)의 기술적 개요와 한의임상적 유용성 고찰)

  • Son, Chang-gue
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.2
    • /
    • pp.85-92
    • /
    • 2015
  • Objectives: The liver fibroscan has been developed as a noninvasive and convenient method to assess hepatic fibrosis. This study aimed to review this device in terms of its technological concept and clinical application in traditional Korean medicine (TKM). Methods: The technological background, diagnostic evaluation, and clinical usefulness of fibroscan were reviewed using various literature and clinical studies. One clinical example-a patient with hepatofibrosis who had been treated with TKM-is presented. Results: The liver fibroscan was approved as a medical device for noninvasive measurement of the hepatic fibrosis level by the Korean Food and Drug Administration (KFDA). Numerous clinical studies have confirmed that its sensitivity and specificity allow it to serve as a substitute for liver biopsy, the present gold standard diagnostic method. The accuracy and reproducibility and lack of technical risks are strong points of the fibroscan; however, it has some limitations for application, especially in patients with obesity or severe hepatitis. One clinical example showed the applicability of the liver fibroscan in herbal medicine-based treatments. Conclusions: The requirement for diagnostic medical devices is an important issue in TKM; therefore, this study provides valuable information for practitioners of TKM.

Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect Device

  • Lee, Sang-Suk;Choi, Jong-Gu;Son, Il-Ho;Kim, Keun-Ho;Nam, Dong-Hyun;Hong, You-Sik;Lee, Woo-Beom;Hwang, Do-Guwn;Rhee, Jang-Roh
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.449-452
    • /
    • 2011
  • A wrist wearable cuffless pulsimeter with a portable and small size apparatus using Hall effect is fabricated. The analysis of the pulse wave measured by the testing product of pulsimeter is done to measure the pulse rate and blood pressure. The blood pressure obtained by the puslimeter is compared with the practical values measured by electronic or mercury liquid blood pressure meters. The detail analysis of a pulse wave measured by a wrist wearable cuffless pulsimeter detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus.

Study on Developing Assessment Guideline for Safety and Performance of Electric Moxibustion Apparatus (전기식 온구기에 대한 안전성 및 성능 평가 가이드라인 개발 연구)

  • Yi, Seung-Ho;Kang, Jung-Won;Nam, Dong-Woo;Kim, Eun-Jung;Lee, Hye-Jung;Kim, Kap-Sung;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.75-86
    • /
    • 2010
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric moxibustion apparatus (class II medical device). Methods : We drafted the guideline for safety and performance assessment of electric moxibustion apparatus by referring the existing standards, guidelines and measurement data from commercially available products. Temperature characteristics such as maximum temperature and ramp time, and physical characteristics such as weight, noise and diameter were measured. User friendliness was also evaluated for commercial devices. Results : This guideline only can be applied to the electric moxibustion apparatus where moxa is being heated by electricity for medical proposes. Maximum temperature of higher than $50^{\circ}C$ can be achieved mostly. Ramp rate of temperature seems to be reliable. Control of temperature is needed to be improved. Moxa and its derivative products seem to be regulated for reliable temperature performance for clinical application. Requirements for design and development of electric moxibustion apparatus are suggested : temperature indicator, temperature control and its accuracy, safety measure, surge protection, user friendliness and instruction for use (IFU). Design recommendation of the reduction of noise level and energy loss are suggested for better products. Conclusions : We proposed a guideline for safety and performance assessment of electric moxibustion apparatus to improve the quality of relating products and aid their commercialization by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

Efficacy Evaluation of Magnetic P. (자기장을 활용한 통증치료기의 효력평가)

  • Yoon, Yoo-Sik;Kim, Sun-Hyoung;Choi, Sun-Mi;Moon, Jin-Seok;Kang, Dong-Kun;Kim, Young;Ahn, Young-Bok;Lee, Jong-Cheol;Jung, Woo-Jin
    • Korean Journal of Oriental Medicine
    • /
    • v.9 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The goal of this study is construction and efficacy evaluation of MPC-25 (Magnetic Pain Control-25), a medical device using magnetic stimulation. MPC-25 consists of a main body containing power supply and control module and a bed containing magnetic core and coil. In distinction from electric pain control medical devices, magnetic pain control system is non-contact, so the patients need not take off their clothes to be treated. High amplitude current pulses are applied to a magnetic coil and induce time varying magnetic field generating eddy current in a conductor like human body. Clinical efficacy test was performed in patients suffering from musculoskeletal pain of lumbar, shoulder and joint. Degree of pain before and after treatment for 30 minutes was compared using Visual Analogous Scale. As a result, 14 cases out of 20 showed decreased pain perception, so the rate of efficacy is 70%. Reduction of pain perception was statistically significant (P=0.001 by Wilcoxon Signed Rank Test).

  • PDF

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

Comparative Study of Therapeutic Effect of Needle-free Bee Venom Aqua-acupuncture (BVA) into Zusanli (ST36) in the Rat Formalin Test (포르말린으로 유도된 통증 유발 쥐에서 무침주입기를 이용한 봉독약침의 진통효과)

  • Jeong, In-Jae;Hahm, Dae-Hyun;Jung, Wu-Byung;Han, Ji-Hee;Chae, Youn-Byoung;Lim, Hyoung-Soo;Lee, Hye-Jung;Kang, Sung-Keel;Kim, Jang-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.2
    • /
    • pp.365-371
    • /
    • 2006
  • Bee Venom aqua-acupuncture (BVA) simultaneously exerts pharmacological effects of biologically active compounds, existed in the whole bee venom, and medicinal effect of the stimulation of acupuncture points. BVA has been considered as a promising therapeutic method for treating various chronic diseases, mainly accompanying severe pain and inflammation. As a painless injection device, jet injectors have been commercially marketed for various clinical applications including insulin injection and vaccination. Among them, a pressure-driven jet injector system could be used for intradermal delivery of a variety of drugs. The aim of this study was to investigate the analgesic effects of the BVA using a needle-free injector (Biojector $2000^{\circledR}$, Bioject Inc., OR, USA), compared to the conventional BV aqua-acupuncture using a typical syringe. Adult Sprague-Dawley rats were injected with bee venom $(0.08mg/kg,\;50{\mu}l)$ using Biojector $2000^{\circledR}$ (BVA-B) or a syringe (BVA-5) into the Zusanli (ST36) acupoint, 30 minutes before plantar injection of 2% formalin. It was found that BVA-B-, or BVA-5-treated rats, compared to controls, exhibited significantly less licking behavior during the late phase in the rat formalin test, when compared to controls. During early phase, however, those effects were not significant but substantial. The analgesic effect of BVA-B was also compatible with that of the conventional BVA-5. In the immunohistochemical studies, BVA-B significantly suppressed the expression of formalin-evoked c-fos, a biomarker of neuronal activity, in the lumbar dorsal horn of the spinal cord. These results indicated that BVA-B waseffective in the modulation of pain in the rat formalin test, compared to BVA-5. Taken together, the needle-free jet injector system could be substituted for the conventional aqua- acupuncture with the advantage of little pain.

A Preliminary Study on the Repeatability of Facial Feature Variables Used in the Sasang Constitutional Diagnosis (체질진단에 활용되는 안면 특징 변수들의 반복성에 대한 예비 연구)

  • Roh, Min-Yeong;Kim, Jong-Yeol;Do, Jun-Hyeong
    • Journal of Sasang Constitutional Medicine
    • /
    • v.29 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • Objectives Facial features can be utilized as an indicator of Korean medical diagnosis. They are often measured by using the diagnostic device for an objective diagnosis. Accordingly, it is necessary to verify the reliability of the features which are obtained from the device for the accurate diagnosis. In this study, we attempt to evaluate the repeatability of facial feature variables using the Sasang Constitutional Analysis Tool(SCAT) for the Sasang Constitutional face diagnosis. Methods Facial pictures of two subjects were taken 24 times respectively for two days according to a standard guideline. In order to evaluate the repeatability, the coefficient of variation was calculated for the facial features extracted from frontal and profile images. Results The coefficient of variation was less than 10% in most of the facial features except the upper lip, trichion, and chins related features. Conclusions It was confirmed that the coefficient of variation was small in most of the features which enables the objective and reliable analysis of face. However, some features showed the low reliability because the location of facial landmarks related to them is ambiguous. In order to solve the problem, a clear basis for the location discussion is required.